文献速递肿瘤 PET/CT放射性药物与辐射防护

深度学习驱动的无CT多示踪剂PET图像器官分割:PET/CT成像中不可靠CT分割的解决方案

Deep Learning-Powered CT-Less Multitracer Organ Segmentation From PET Images: A Solution for Unreliable CT Segmentation in PET/CT Imaging.
PubMed 文献 · Clin Nucl Med · 2025-01-28

本研究收集2062例PET/CT图像,其中18F-FDG 1487例、68Ga-PSMA 575例,训练4种深度学习模型分别基于非校正PET和衰减散射校正PET进行多器官分割,不依赖CT信息。各任务平均Dice系数为0.81±0.15、0.82±0.14、0.77±0.17、0.79±0.16,PET-ASC模型在多数器官优于PET-NC模型(P<0.05),脑部Dice最高(0.93-0.96),小器官如肾上腺最低。

要点

  • 深度学习模型可在不使用CT信息的情况下对18F-FDG和68Ga-PSMA两种PET示踪剂实现高性能多器官分割。
  • 各任务平均Dice系数分别为0.81±0.15、0.82±0.14、0.77±0.17、0.79±0.16。
  • PET-ASC模型在多数器官优于PET-NC模型(P<0.05),脑部Dice最高(0.93-0.96),肾上腺等小器官最低。

核心结论

  • 深度学习模型允许对2种常用PET示踪剂进行高性能多器官分割,而无需使用CT信息。
  • 这些模型可能解决PET/CT图像定量、动力学建模、放射组学分析、剂量学或其他需要器官分割掩码的任务中使用CT分割的局限性。

研究设计与样本

  • 收集来自多台扫描仪的2062例PET/CT图像,患者注射18F-FDG(1487例)或68Ga-PSMA(575例)。
  • 通过视觉评估检测PET与CT图像之间存在任何不匹配的PET/CT图像,并将其排除。
  • 使用先前训练的本院开发nnU-Net模型在CT组件上勾画多个器官,分割掩码重采样至配准PET图像,用于训练4种不同深度学习模型。
  • 任务1和2分别使用18F-FDG的非校正PET(PET-NC)和衰减散射校正PET(PET-ASC),涉及22个器官;任务3和4分别使用68Ga示踪剂的PET-NC和PET-ASC,涉及15个器官。
  • 模型性能以Dice系数、Jaccard指数和分割体积差异评估。

主要发现

  • 所有器官的平均Dice系数在任务1、2、3、4分别为0.81±0.15、0.82±0.14、0.77±0.17、0.79±0.16。
  • 对于大多数器官,PET-ASC模型优于PET-NC模型(P<0.05)。
  • 脑部Dice值最高(所有4个任务中为0.93至0.96),而肾上腺等小器官Dice值最低。
  • 训练模型在动态噪声图像上也表现出稳健性能。

关键数值与推荐

  • 所有器官平均Dice系数:任务1为0.81±0.15,任务2为0.82±0.14,任务3为0.77±0.17,任务4为0.79±0.16。
  • PET-ASC模型在多数器官优于PET-NC模型(P<0.05)。
  • 脑部Dice值在所有4个任务中为0.93至0.96。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The common approach for organ segmentation in hybrid imaging relies on coregistered CT (CTAC) images. This method, however, presents several limitations in real clinical workflows where mismatch between PET and CT images are very common. Moreover, low-dose CTAC images have poor quality, thus challenging the segmentation task. Recent advances in CT-less PET imaging further highlight the necessity for an effective PET organ segmentation pipeline that does not rely on CT images. Therefore, the goal of this study was to develop a CT-less multitracer PET segmentation framework. PATIENTS AND METHODS: We collected 2062 PET/CT images from multiple scanners. The patients were injected with either 18 F-FDG (1487) or 68 Ga-PSMA (575). PET/CT images with any kind of mismatch between PET and CT images were detected through visual assessment and excluded from our study. Multiple organs were delineated on CT components using previously trained in-house developed nnU-Net models. The segmentation masks were resampled to coregistered PET images and used to train 4 different deep learning models using different images as input, including noncorrected PET (PET-NC) and attenuation and scatter-corrected PET (PET-ASC) for 18 F-FDG (tasks 1 and 2, respectively using 22 organs) and PET-NC and PET-ASC for 68 Ga tracers (tasks 3 and 4, respectively, using 15 organs). The models' performance was evaluated in terms of Dice coefficient, Jaccard index, and segment volume difference. RESULTS: The average Dice coefficient over all organs was 0.81 ± 0.15, 0.82 ± 0.14, 0.77 ± 0.17, and 0.79 ± 0.16 for tasks 1, 2, 3, and 4, respectively. PET-ASC models outperformed PET-NC models ( P < 0.05) for most of organs. The highest Dice values were achieved for the brain (0.93 to 0.96 in all 4 tasks), whereas the lowest values were achieved for small organs, such as the adrenal glands. The trained models showed robust performance on dynamic noisy images as well. CONCLUSIONS: Deep learning models allow high-performance multiorgan segmentation for 2 popular PET tracers without the use of CT information. These models may tackle the limitations of using CT segmentation in PET/CT image quantification, kinetic modeling, radiomics analysis, dosimetry, or any other tasks that require organ segmentation masks.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Salimi Y, Mansouri Z, Shiri I, et al. Deep Learning-Powered CT-Less Multitracer Organ Segmentation From PET Images: A Solution for Unreliable CT Segmentation in PET/CT Imaging. Clin Nucl Med. 2025. PMID: 39883026. doi:10.1097/RLU.0000000000005685

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。