文献速递肿瘤 PET/CT

组织非依赖性正电子射程校正在[68Ga]Ga-DOTATOC与[68Ga]Ga-PSMA PET图像重建中的影响:一项患者数据研究

Impact of tissue-independent positron range correction on [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA PET image reconstructions: a patient data study.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-01-29

本研究利用40例患者的[68Ga]Ga-DOTATOC或[68Ga]Ga-PSMA PET/CT数据,比较Q.Clear重建加与不加组织非依赖性正电子射程校正(PRC)的效果。共识别155个病灶,PRC使软组织、骨和肺病灶的SUVmax与CNR均显著升高,小病灶效应最明显;5名核医学医师视觉评估认为PRC图像质量、病灶可检出性和诊断信心相似或更好。

要点

  • PRC使软组织病灶SUVmax升高6.4%、CNR升高8.6%(均p<0.001)。
  • PRC使骨病灶SUVmax升高14.6%、CNR升高12.5%(均p<0.001)。
  • PRC使肺病灶SUVmax升高3.6%(p=0.010)、CNR升高6.3%(p=0.001)。

核心结论

  • 组织非依赖性PRC可提高软组织、骨和肺病灶的SUVmax与CNR,对小病灶效应更大。
  • 视觉评估显示PRC图像在图像质量、病灶可检出性和诊断信心方面与无PRC图像相似或更好。

研究设计与样本

  • 患者数据研究,纳入40例接受[68Ga]Ga-DOTATOC或[68Ga]Ga-PSMA PET/CT检查的患者。
  • 采用Q.Clear重建算法,每例患者分别进行加PRC与不加PRC两种重建。
  • 比较每病灶的SUVmax和对比噪声比(CNR),并由5名经验丰富的核医学医师进行视觉评估。

主要发现

  • 共识别155个病灶。
  • 软组织病灶:PRC组SUVmax较无PRC组升高6.4%(p<0.001),CNR升高8.6%(p<0.001)。
  • 骨病灶:PRC组SUVmax较无PRC组升高14.6%(p<0.001),CNR升高12.5%(p<0.001)。
  • 肺病灶:PRC组SUVmax较无PRC组升高3.6%(p=0.010),CNR升高6.3%(p=0.001)。
  • 小病灶效应最明显:SUVmax升高12.0%(p<0.001),CNR升高13.0%(p<0.001)。

关键数值与推荐

  • 5名核医学医师基于图像质量、病灶可检出性和诊断信心选择偏好的重建图像。
  • 专家评估认为PRC图像在图像质量、病灶可检出性和诊断信心方面与无PRC图像相似或更好。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The positron range effect can impair PET image quality of Gallium-68 (68Ga). A positron range correction (PRC) can be applied to reduce this effect. In this study, the effect of a tissue-independent PRC for 68Ga was investigated on patient data. METHODS: PET/CT data (40 patients: [68Ga]Ga-DOTATOC or [68Ga]Ga-PSMA) were reconstructed using Q.Clear reconstruction algorithm. Two reconstructions were performed per patient, Q.Clear with and without PRC. SUVmax and contrast-to-noise ratio (CNR) values per lesion were compared between PRC and non-PRC images. Five experienced nuclear medicine physicians reviewed the images and chose the preferred reconstruction based on the image quality, lesion detectability, and diagnostic confidence. RESULTS: A total of 155 lesions were identified. The PRC resulted in statistically significant increase of the SUVmax and CNR for soft tissue lesions (6.4%, p < 0.001; 8.6%, p < 0.001), bone lesions (14.6%, p < 0.001; 12.5%, p < 0.001), and lung lesions (3.6%, p = 0.010; 6.3%, p = 0.001). This effect was most prominent in small lesions (SUVmax: 12.0%, p < 0.001, and CNR: 13.0%, p < 0.001). Similar or better image quality, lesion detectability, and diagnostic confidence was achieved in PRC images compared to the non-PRC images as those assessed by the expert readers. CONCLUSIONS: A tissue-independent PRC increased the SUVmax and CNR in soft tissue, bone, and lung lesions with a larger effect for the small lesions. Visual assessment demonstrated similar or better image quality, lesion detectability, and diagnostic confidence in PRC images compared to the non-PRC images.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Gavriilidis P, Mottaghy FM, Koole M, et al. Impact of tissue-independent positron range correction on [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA PET image reconstructions: a patient data study. Eur J Nucl Med Mol Imaging. 2025. PMID: 39878896. doi:10.1007/s00259-024-07061-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。