放射流式细胞术揭示K-RAS肺癌中[18F]FDG摄取由免疫细胞驱动:单细胞水平分析
本研究在两种Kirsten大鼠肉瘤病毒驱动的肺癌小鼠模型中注射[18F]FDG行小动物PET/CT,并对肺组织进行荧光激活细胞分选,再用γ计数器测量分选细胞组分的放射性并归一化至细胞数。放射流式细胞术分析显示[18F]FDG PET信号主要来自免疫细胞(CD45+、F4/80-,78.3%±6.6%;巨噬细胞,13.9%±4.3%),而肿瘤细胞仅贡献2.8%±1.0%,与结构细胞(CD45-;肿瘤细胞,5.0%±2.3%)相似;归一化后巨噬细胞在两种肿瘤模型中葡萄糖代谢最高(57%±8%),其余免疫细胞次之(27%±3%)。作者认为免疫细胞代谢对[18F]FDG显像有重要影响,解读癌症[18F]FDG显像时需考虑免疫细胞的贡献。
要点
- 放射流式细胞术显示两种K-RAS肺癌小鼠模型肺内[18F]FDG摄取呈稳健的细胞类型特异性模式。
- [18F]FDG PET信号主要来自免疫细胞(CD45+、F4/80-,78.3%±6.6%;巨噬细胞,13.9%±4.3%)。
- 肿瘤细胞贡献仅2.8%±1.0%,归一化后巨噬细胞葡萄糖代谢最高(57%±8%)。
核心结论
- 作者认为这些发现凸显免疫细胞代谢对[18F]FDG显像的关键影响,强调解读癌症[18F]FDG显像时需考虑免疫细胞的贡献。
研究设计与样本
- 研究在两种Kirsten大鼠肉瘤病毒驱动的肺癌小鼠模型中注射[18F]FDG行小动物PET/CT,并对肺组织行荧光激活细胞分选。
- 放射流式细胞术将分选细胞组分在γ计数器测量放射性,并归一化至细胞数。
主要发现
- 两种模型肺组织放射流式细胞术分析在各实验中均显示稳健的细胞类型特异性摄取模式。
- [18F]FDG PET信号主要来自免疫细胞(CD45+、F4/80-,78.3%±6.6%;巨噬细胞,13.9%±4.3%)。
- 肿瘤细胞贡献仅2.8%±1.0%,与结构细胞(CD45-;肿瘤细胞,5.0%±2.3%)相似。
- 归一化后巨噬细胞在两种肿瘤模型中葡萄糖代谢最高(57%±8%),其余免疫细胞次之(27%±3%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Tumor metabolism is a hallmark of cancer, yet cellular heterogeneity within the tumor microenvironment presents a significant challenge, as bulk analysis masks the diverse metabolic profiles of individual cell populations. This complexity complicates our understanding of [18F]FDG uptake by distinct cell types in the tumor microenvironment. This study aims to investigate [18F]FDG uptake at the single-cell level in the lung of Kirsten rat sarcoma virus-driven cancer mouse models using the novel technique radio-flow cytometry (radioFlow). Methods: Two Kirsten rat sarcoma virus-driven lung cancer mouse models were injected with [18F]FDG for small-animal PET/CT and subsequent fluorescence-activated cell sorting of the lung. For radioFlow, the sorted cell fractions were then measured in a γ-counter and their radioactivity was normalized to the number of cells. Results: RadioFlow analysis of the lung tissue of both models showed a robust cell type-specific uptake pattern across experiments. Our key findings indicate that the [18F]FDG PET signal predominantly derives from immune cells (CD45+, F4/80-, 78.3% ± 6.6%; macrophage, 13.9% ± 4.3%), whereas tumor cells contributed only with 2.8% ± 1.0%, similar to the uptake of structural cells (CD45-; tumor cells, 5.0% ± 2.3%). Normalization showed that macrophages exhibited the highest glucose metabolism in both tumor models (57% ± 8%), followed by the remaining immune cells (27% ± 3%). Conclusion: These findings highlight the critical influence of immune cell metabolism on [18F]FDG imaging, emphasizing the need to account for immune contributions when interpreting [18F]FDG imaging in cancer.
引用
- Vraka C, Homolya M, Özer Ö, et al. RadioFlow Cytometry Reveals That [18F]FDG Uptake in K-RAS Lung Cancer Is Driven by Immune Cells: An Analysis on a Single-Cell Level. J Nucl Med. 2025. PMID: 39819684. doi:10.2967/jnumed.124.268799
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。