定量骨SPECT/CT参数可预测有症状的拇指基底关节关节炎保守治疗的成功
这项回顾性研究纳入78例(128只手)有症状的拇指基底关节关节炎患者,评估骨SPECT/CT定量参数对预测保守治疗成功的价值。多因素logistic回归显示,仅高SUVmax与保守治疗成功显著相关(OR 1.097,95%CI 1.027-1.172,P=0.006)。SUVmax预测保守治疗成功的ROC曲线下面积为0.649(95%CI 0.554-0.744,P=0.002),以9.52为截断值时灵敏度56.3%、特异度70.3%。
要点
- 多因素分析中仅高SUVmax与保守治疗成功显著相关(OR 1.097,P=0.006)。
- SUVmax预测保守治疗成功的AUC为0.649(95%CI 0.554-0.744,P=0.002)。
- SUVmax截断值9.52时预测成功的灵敏度56.3%、特异度70.3%。
核心结论
- 骨SPECT/CT上初始高SUVmax与有症状的拇指基底关节关节炎保守治疗成功显著相关。
研究设计与样本
- 回顾性纳入2019年4月至2023年4月间78例(128只手)有症状的拇指基底关节关节炎患者,均在初诊后4周内行骨SPECT/CT并完成超过6个月的保守治疗。
- 在4个周舟骨关节测量SUVmax,取最高摄取值用于分析;以PRWHE的最小临床重要差异将128只手分为治疗成功组64只(50.0%)和失败组64只(50.0%)。
主要发现
- 多因素logistic回归分析中,仅高SUVmax与保守治疗成功显著相关(OR 1.097,95%CI 1.027-1.172,P=0.006)。
- ROC曲线分析中,SUVmax的曲线下面积为0.649(95%CI 0.554-0.744,P=0.002)。
- SUVmax以9.52为截断值预测保守治疗成功时,灵敏度为56.3%、特异度为70.3%。
关键数值与推荐
- 以PRWHE的最小临床重要差异为分组标准,128只手中治疗成功组64只(50.0%)、失败组64只(50.0%)。
- SUVmax预测保守治疗成功的截断值为9.52,灵敏度56.3%、特异度70.3%,AUC 0.649(95%CI 0.554-0.744,P=0.002)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The aim of this study was to evaluate the role of quantitatively assessed bone SPECT/CT parameters for predicting the success of conservative treatment for symptomatic basal joint arthritis of the thumb. PATIENTS AND METHODS: Seventy-eight patients (128 hands) with symptomatic basal joint arthritis of the thumb who underwent bone SPECT/CT scans within 4 weeks after their initial visit and completed conservative treatment for more than 6 months between April 2019 and April 2023 were retrospectively enrolled. PRWHE (patient-rated wrist/hand evaluation) was evaluated in all patients before and after the treatment. The SUV max from bone SPECT/CT was measured in the 4 peritrapezial joints, and the highest uptake was used for analysis. RESULTS: On the basis of the minimal clinically important difference in PRWHE scores, 64 hands (50.0% of 128 hands) were classified as the treatment success group and 64 hands (50.0% of 128 hands) were failure group. In multivariate logistic regression analysis, only high SUV max (odds ratio, 1.097; 95% confidence interval, 1.027-1.172; P = 0.006) was a factor significantly associated with the success of conservative treatment. In receiver operating characteristics curve analysis, the area under the curve of SUV max was 0.649 (95% confidence interval, 0.554-0.744; P = 0.002). As a prognostic parameter for the success of conservative treatment, SUV max showed a sensitivity of 56.3% and specificity of 70.3% with a cutoff of 9.52. CONCLUSIONS: High initial SUV max on bone SPECT/CT was significantly associated with the success of conservative treatment for symptomatic basal joint arthritis of the thumb.
引用
- Kim YI, Ryu JS, Kim JK, et al. Quantitative Bone SPECT/CT Parameters Could Predict the Success of the Conservative Treatment for Symptomatic Basal Joint Arthritis of the Thumb. Clin Nucl Med. 2024. PMID: 39601062. doi:10.1097/RLU.0000000000005576
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。