深度学习网络心脏运动校正用于单光子发射计算机断层扫描心肌灌注显像灌注缺损评估

Cardiac motion correction with a deep learning network for perfusion defect assessment in single-photon emission computed tomography myocardial perfusion imaging.
PubMed 文献 · J Nucl Cardiol · 2024-11-02

研究采用深度学习网络对心电图门控SPECT-MPI图像进行心脏运动校正,训练集197例,测试集194例临床数据(插入模拟病灶作为金标准)。ROC分析显示,DL运动校正显著提高标准计数和减计数研究的灌注缺损检出率;联合两个参考相位评估在四分之一计数数据上AUC=0.841,高于未门控全计数数据的AUC=0.795(P=0.0054)。

要点

  • DL运动校正可显著提高标准计数和减计数SPECT-MPI研究的灌注缺损检出率。
  • 检出率随参考心脏相位变化;联合两个参考相位评估四分之一计数数据AUC=0.841。
  • 四分之一计数数据联合两相位AUC高于未门控全计数数据AUC=0.795(P=0.0054)。

核心结论

  • DL运动校正有益于标准计数和减计数SPECT-MPI研究的灌注缺损评估,也有益于在多个心脏相位上评估灌注图像。

研究设计与样本

  • 采用深度学习网络对心电图门控SPECT-MPI图像进行心脏运动校正,将不同心脏相位的图像数据相对于参考门合并以减少运动模糊。
  • DL网络训练使用197例;测试使用独立的194例临床受试者数据集,研究图像由实际患者数据插入模拟病灶作为金标准创建。
  • 重建图像由定量灌注SPECT(QPS)软件评估;并评估减计数研究(减少两倍和四倍)的性能。

主要发现

  • 以ROC曲线下面积(AUC)衡量的定量结果表明,DL运动校正显著提高标准计数和减计数研究的灌注缺损检出率,且检出率可随参考心脏相位变化。
  • 联合两个参考相位评估在四分之一计数数据上达到AUC=0.841,高于未门控全计数数据的AUC=0.795(P=0.0054)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT), ungated studies are used for evaluation of perfusion defects despite motion blur. We investigate the potential benefit of motion correction using a deep-learning (DL) network for evaluating perfusion defects. METHODS: We employed a DL network for cardiac motion correction in ECG-gated SPECT-MPI images, wherein the image data from different cardiac phases are combined with respect to a reference gate to reduce motion blur. For training the DL network, 197 cases were used. Given the variability of gated images during the cardiac cycle, we investigated the detectability of perfusion defects in two distinct reference gates. To assess perfusion defect detection, we performed receiver-operating characteristic (ROC) analyses on the motion-corrected images using a separate test dataset of clinical 194 subjects, in which studies were created from actual patient data with inserted simulated-lesions as ground truth. The reconstructed images were assessed by the quantitative-perfusion SPECT (QPS) software. We also evaluated the performance on reduced-count studies (by two and four folds). RESULTS: The quantitative results, measured by area-under-the-ROC curve (AUC), demonstrated that DL motion correction improves the detectability of perfusion defects significantly on both standard- and reduced-count studies, and that the detectability can vary with reference cardiac phases. A joint assessment from two reference phases achieved AUC = 0.841 on the quarter-count data, higher than with ungated full-count data (AUC = 0.795, P-value = 0.0054). CONCLUSIONS: DL motion correction can benefit assessment of perfusion defects in standard- and reduced-count SPECT-MPI studies. It can also be beneficial to evaluate perfusion images over multiple cardiac phases.