文献速递神经核医学

自身免疫性脑炎的区域代谢异常:498例脑FDG PET的Meta分析

Regional Metabolic Abnormalities in Autoimmune Encephalitis: A Meta-analysis of 498 Cases With Brain FDG PET.
PubMed 文献 · Clin Nucl Med · 2024-11-27

该Meta分析依据PRISMA指南系统检索,纳入234项研究共498例自身免疫性脑炎(AIE)患者,逐例提取MRI与脑FDG PET结果。FDG PET异常率为93%,MRI为55%;FDG PET较MRI更常检出异常,尤其在抗NMDAR和抗GABA-B抗体病例中,且代谢改变模式随相关抗体而异。

要点

  • FDG PET异常检出率93%,高于MRI的55%。
  • 抗NMDAR和抗GABA-B抗体病例中FDG PET较MRI更常检出异常。
  • 内侧颞叶高代谢及顶叶、枕叶低代谢均常见,模式随抗体不同而异。

核心结论

  • FDG PET较MRI更常检出异常,尤其在抗NMDAR和抗GABA-B抗体病例中。
  • 内侧颞叶高代谢及顶叶、枕叶低代谢均常见,结果随相关抗体不同而异。
  • 作者认为该发现强化了FDG PET在疑似AIE患者中的重要性,抗体相关区域代谢异常模式作为诊断和预后工具具有较大进一步开发潜力。

研究设计与样本

  • 按PRISMA指南进行的系统综述与Meta分析,检索旨在识别所有至少包含1例AIE并接受脑FDG PET检查的研究。
  • 文献检索获得1303条结果,最终纳入234项研究、共498例病例,逐例提取MRI与FDG PET结果,包括病例报告和病例系列。

主要发现

  • FDG PET异常发现报告率为93%,MRI为55%。
  • 受累脑区、单侧与双侧表现的比例、高代谢与低代谢的比例按相关抗体分类以表格描述性呈现。
  • FDG PET较MRI更常检出异常,尤其在抗NMDAR和抗GABA-B抗体病例中。
  • 内侧颞叶高代谢常见,顶叶和枕叶低代谢也常见,结果随相关抗体不同而异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Autoimmune encephalitis (AIE) is a group of conditions that are insufficiently understood and difficult to diagnose. Several publications indicate that FDG PET has superior sensitivity compared with MRI. This study aimed to perform a systematic review of publications to assess the characteristics and frequency of brain FDG PET compared with MRI findings at the individual level in AIE, including case reports and case series. The resulting meta-analysis is complementary to previous publications with large or medium-sized cohorts. PATIENTS AND METHODS: The review was performed using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and aimed to identify all studies with at least 1 case of AIE in which brain FDG PET was performed. Results from MRI and FDG PET were extracted on a patient-by-patient basis. RESULTS: The literature search yielded 1303 results, of which 234 studies were included, containing 498 cases. Abnormal FDG PET findings are reported in 93% compared with 55% with MRI. The affected brain regions, rates of unilateral versus bilateral findings, and hypermetabolism versus hypometabolism are descriptively presented in tables categorized according to the associated antibody. CONCLUSIONS: FDG PET detected abnormalities more frequently than MRI, particularly in cases with anti-NMDAR and anti-GABA-B antibodies. Findings include a high prevalence of hypermetabolism in the medial temporal lobes, but also a high prevalence of parietal and occipital hypometabolism. Results differed depending on the associated antibody. Overall, the findings strengthen the importance of FDG PET in patients with suspected AIE, and the antibody-related patterns of regional metabolic abnormalities indicate a high potential for further development as a diagnostic and prognostic tool.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Kosek S, Kilsved E, Danfors T, et al. Regional Metabolic Abnormalities in Autoimmune Encephalitis: A Meta-analysis of 498 Cases With Brain FDG PET. Clin Nucl Med. 2024. PMID: 39601059. doi:10.1097/RLU.0000000000005574

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。