文献速递肿瘤 PET/CT

基于2-[18F]FDG PET/CT的影像组学在预测透明细胞肾细胞癌WHO/ISUP分级中的价值

The value of radiomics based on 2-[18 F]FDG PET/CT in predicting WHO/ISUP grade of clear cell renal cell carcinoma.
PubMed 文献 · EJNMMI Res · 2024-11-21

研究纳入2016年12月至2023年12月间行2-[18F]FDG PET/CT的209例患者共214个病灶,按7:3分为训练组与测试组,以不同SUVmax阈值提取影像组学特征构建临床、影像组学及联合模型预测透明细胞肾细胞癌WHO/ISUP分级。联合模型训练组与测试组AUC均为0.916,显示基于2-[18F]FDG PET/CT的影像组学有助于预测WHO/ISUP分级。

要点

  • 联合模型训练组AUC为0.916、敏感度0.923、特异度0.808
  • 测试组临床模型AUC为0.882,影像组学模型AUC为0.901
  • 不同SUVmax阈值建立的PET模型训练组AUC为0.881至0.889

核心结论

  • 基于2-[18F]FDG PET/CT的影像组学有助于预测透明细胞肾细胞癌的WHO/ISUP分级。

研究设计与样本

  • 纳入2016年12月至2023年12月行2-[18F]FDG PET/CT的209例患者共214个病灶,按7:3分为训练组与测试组。
  • 将病灶分为低级别(WHO/ISUP I-II级)与高级别(WHO/ISUP III-IV级),以SUVmax阈值0、2.5%、25%、40%提取影像组学特征,采用mRMR与LASSO回归算法,构建临床、影像组学及联合模型并用ROC曲线、决策曲线和校准曲线评估。

主要发现

  • 训练组PET-0、PET-2.5%、PET-25%、PET-40%模型AUC分别为0.881(95%CI 0.822-0.940)、0.883(95%CI 0.825-0.942)、0.889(95%CI 0.831-0.946)、0.887(95%CI 0.826-0.948)。
  • 测试组PET-0、PET-2.5%、PET-25%、PET-40%模型AUC分别为0.878(95%CI 0.777-0.978)、0.876(95%CI 0.776-0.977)、0.871(95%CI 0.769-0.972)、0.882(95%CI 0.786-0.979)。
  • 训练组临床模型AUC为0.859(敏感度0.846,特异度0.747),影像组学模型AUC为0.909(敏感度0.808,特异度0.751)。
  • 测试组临床模型AUC为0.882(敏感度0.857,特异度0.857),影像组学模型AUC为0.901(敏感度0.905,特异度0.833)。
  • 联合模型训练组AUC为0.916、敏感度0.923、特异度0.808,原文对测试组联合模型写为「训练组AUC 0.916、敏感度0.881、特异度0.792」,原文此处表述有矛盾。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim is to develop and validate radiomics based on 2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (2-[18F]FDG PET/CT) parameters for predicting the World Health Organization/International Society of Urological Pathology (WHO/ISUP) grade of clear cell renal cell carcinoma (ccRCC). METHODS: A total of 209 patients with 214 lesions, who underwent 2-[18F]FDG PET/CT scans between December 2016 to December 2023, were included in our study. All ccRCC lesions were categorized into low grade (WHO/ISUP grade I-II) and high grade (WHO/ISUP grade III-IV). The lesions were allocated into a training group and a testing group in a ratio of 7:3. The radiomics features were extracted by a serious of maximum standardized uptake value (SUVmax) thresholds (0,2.5%,25%,40%) with the utilization of the minimum redundancy and maximum relevance (mRMR) and least absolute shrinkage and selection operator (LASSO) regression algorithm. The clinical, radiomics and combined models were constructed. The receiver operating characteristic (ROC) curve, decision curve and calibration curves were plotted to assess the predicting performance. RESULTS: The area under curve (AUC) of PET-0, PET-2.5%, PET-25%, PET-40% model in the training group were 0.881(95% CI: 0.822-0.940),0.883(95% CI: 0.825-0.942),0.889(95% CI: 0.831-0.946),0.887(95% CI: 0.826-0.948); and 0.878(95% CI: 0.777-0.978),0.876(95% CI: 0.776-0.977),0.871(95% CI: 0.769-0.972),0.882(95% CI: 0.786-0.979) in the testing group. Due to perfect prediction and verification performance, the volume of interest (VOI) from PET images with SUVmax threshold of 40% were selected to construct the radiomics model and combined model. The AUC of the clinical model and radiomics model was 0.859 (sensitivity = 0.846, specificity = 0.747) and 0.909 (sensitivity = 0.808, specificity = 0.751) in the training group, respectively; 0.882 (sensitivity = 0.857, specificity = 0.857) and 0.901 (sensitivity = 0.905, specificity = 0.833) in the testing group, respectively. In combined models, the AUC was 0.916, the sensitivity was 0.923 and the specificity was 0.808 in the training group; the AUC was 0.916, the sensitivity was 0.881 and the specificity was 0.792 in the training group. CONCLUSION: Radiomics based on 2-[18F]FDG PET/CT can be helpful to predict WHO/ISUP grade of ccRCC.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Han Y, Wang G, Zhang J, et al. The value of radiomics based on 2-[18 F]FDG PET/CT in predicting WHO/ISUP grade of clear cell renal cell carcinoma. EJNMMI Res. 2024. PMID: 39570474. doi:10.1186/s13550-024-01182-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。