利用PET/CT影像组学区分不明原因发热中的淋巴瘤与良性淋巴结疾病
本研究纳入204例因不明原因发热(FUO)行18F-FDG PET/CT检查的患者(淋巴瘤114例、良性淋巴结病变90例),按7:3随机分为训练组和测试组,基于15个有效特征构建LR、SVM、RF和KNN机器学习模型。训练组RF模型AUC最高(0.998),测试组四种模型AUC为0.860~0.915且组间无统计学显著差异,RF模型决策曲线分析表现最佳。结论认为PET/CT影像组学在区分FUO患者淋巴瘤与良性淋巴结病变方面表现良好,RF模型性能最佳。
要点
- 训练组RF模型AUC为0.998,与LR、SVM、KNN模型差异均有统计学意义(均P<0.001)。
- 测试组LR、SVM、RF、KNN的AUC分别为0.860、0.866、0.915、0.891,组间差异均无统计学意义(均P>0.05)。
- RF模型在训练组和测试组的决策曲线分析均优于其他三种模型。
核心结论
- PET/CT影像组学在区分FUO患者淋巴瘤与良性淋巴结病变方面表现出良好性能,RF模型表现最佳。
研究设计与样本
- 数据来自204例因FUO行18F-FDG PET/CT检查的患者,包括114例淋巴瘤和90例良性淋巴结病变患者。
- 患者按7:3比例随机分为训练组和测试组。
- 采用LASSO算法获得15个有效特征,使用LR、SVM、RF和KNN算法构建机器学习模型。
主要发现
- 训练组中LR、SVM、RF、KNN模型预测淋巴瘤与良性病例的AUC分别为0.936、0.930、0.998、0.938。
- 训练组中RF与其他模型的AUC差异均有统计学意义(均P<0.001)。
- 测试组中四种模型的AUC分别为0.860、0.866、0.915、0.891,组间差异均无统计学意义(均P>0.05)。
- RF模型的决策曲线分析曲线在训练组和测试组均优于其他三种模型。
关键数值与推荐
- 训练组RF模型AUC为0.998,LR为0.936,SVM为0.930,KNN为0.938。
- 测试组RF模型AUC为0.915,KNN为0.891,SVM为0.866,LR为0.860。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A considerable portion of patients with fever of unknown origin (FUO) present concomitant lymphadenopathy. Diseases within the spectrum of FUO accompanied by lymphadenopathy include lymphoma, infections, and rheumatic diseases. Particularly, lymphoma has emerged as the most prevalent etiology of FUO with associated lymphadenopathy. Distinguishing between benign and malignant lymph node lesions is a major challenge for physicians and an urgent clinical concern for patients. However, conventional imaging techniques, including PET/CT, often have difficulty accurately distinguishing between malignant and benign lymph node lesions. This study utilizes PET/CT radiomics to differentiate between lymphoma and benign lymph node lesions in patients with FUO, aiming to improve diagnostic accuracy. RESULTS: Data were collected from 204 patients who underwent 18F-FDG PET/CT examinations for FUO, including 114 lymphoma patients and 90 patients with benign lymph node lesions. Patients were randomly divided into training and testing groups at a ratio of 7:3. A total of 15 effective features were obtained by the least absolute shrinkage and selection operator (LASSO) algorithm. Machine learning models were constructed using logistic regression (LR), support vector machine (SVM), random forest (RF), and k-nearest neighbors (KNN) algorithms. In the training group, the area under the curve (AUC) values for predicting lymphoma and benign cases by LR, SVM, RF, and KNN models were 0.936, 0.930, 0.998, and 0.938, respectively. There were statistically significant differences in AUC between the RF and other models (all P < 0.001). In the testing group, the AUC values for the four models were 0.860, 0.866, 0.915, and 0.891, respectively, with no statistically significant differences observed among them (all P > 0.05). The decision curve analysis (DCA) curves of the RF model outperformed those of the other three models in both the training and testing groups. CONCLUSIONS: PET/CT radiomics demonstrated promising performance in discriminating lymphoma from benign lymph node lesions in patients with FUO, with the RF model showing the best performance.
引用
- Zhang X, Jing F, Hu Y, et al. Distinguishing lymphoma from benign lymph node diseases in fever of unknown origin using PET/CT radiomics. EJNMMI Res. 2024. PMID: 39537895. doi:10.1186/s13550-024-01171-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。