[68Ga]Ga-DOTA-FAPI-04 PET/MR与[18F]-FDG PET/CT联合增强CT术前评估胰腺癌的前瞻性初步研究
31例胰腺癌患者术前行[68Ga]Ga-DOTA-FAPI-04 PET/MR与[18F]-FDG PET/CT联合增强CT(CECT)检查,比较肿瘤可切除性、N分期和M分期的诊断效能。两种影像在可切除性评估、N分期和M分期的诊断效能无显著差异,但[68Ga]Ga-DOTA-FAPI-04 PET/MR在肝转移灶和腹膜转移灶检出数量上更多。
要点
- 两种影像评估可切除性、N分期及M分期的诊断效能无显著差异。
- [68Ga]Ga-DOTA-FAPI-04 PET/MR使3例患者M分期发生改变。
- [68Ga]Ga-DOTA-FAPI-04 PET/MR检出的肝转移灶和腹膜转移灶数量更多。
核心结论
- [68Ga]Ga-DOTA-FAPI-04 PET/MR在胰腺癌术前分期和可切除性评估方面具有与[18F]-FDG PET/CT联合CECT相当的诊断准确性。
- [68Ga]Ga-DOTA-FAPI-04 PET/MR在检出肝转移和腹膜转移方面表现出更优的能力。
- [68Ga]Ga-DOTA-FAPI-04 PET/MR有潜力成为胰腺癌术前评估的一站式影像工具。
研究设计与样本
- 前瞻性初步研究,纳入31例胰腺癌患者。
- 患者术前行[68Ga]Ga-DOTA-FAPI-04 PET/MR、[18F]-FDG PET/CT和CECT检查。
- 两名核医学医师独立阅片,分别判读[68Ga]Ga-DOTA-FAPI-04 PET/MR(组1)与[18F]-FDG PET/CT联合CECT(组2),对肿瘤可切除性、N分期(N0或N阳性)和M分期(M0或M1)达成共识。
- 根据上述指标采用五点量表判定肿瘤可切除性。
- 以临床、手术和病理结果为参考标准,采用McNemar检验比较两组影像的诊断效能。
主要发现
- 可切除性评估的受试者工作特征曲线下面积:[68Ga]Ga-DOTA-FAPI-04 PET/MR组0.854 vs [18F]-FDG PET/CT联合CECT组0.775(p=0.192)。
- N分期准确性:[68Ga]Ga-DOTA-FAPI-04 PET/MR组82.4%(14/17例)vs [18F]-FDG PET/CT联合CECT组58.8%(10/17例),p=0.125。
- M分期准确性:[68Ga]Ga-DOTA-FAPI-04 PET/MR组100%(31/31例)vs [18F]-FDG PET/CT联合CECT组90.3%(28/31例),p=0.250。
- 与[18F]-FDG PET/CT联合CECT相比,[68Ga]Ga-DOTA-FAPI-04 PET/MR使3例患者M分期改变,其中2例从M0上调至M1,2例从M1下调至M0。
- 在13例肝转移患者中,[68Ga]Ga-DOTA-FAPI-04 PET/MR检出肝转移灶数量多于[18F]-FDG PET/CT联合CECT(324 vs 240)。
临床怎么用
- 原文结论指出[68Ga]Ga-DOTA-FAPI-04 PET/MR有潜力成为胰腺癌术前评估的一站式影像工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the diagnostic performance of [68Ga]Ga-DOTA-FAPI-04 PET/MR imaging in the preoperative evaluation of pancreatic cancer and compare it with that of [18F]-FDG PET/CT plus contrast-enhanced CT (CECT). METHODS: Thirty-one patients with pancreatic cancer underwent preoperative [68Ga]Ga-DOTA-FAPI-04 PET/MR, [18F]-FDG PET/CT, and CECT imaging. Two nuclear medicine physicians independently reviewed two sets of images (set 1, [68Ga]Ga-DOTA-FAPI-04 PET/MR; set 2, [18F]-FDG PET/CT plus CECT) and reached a consensus on tumour resectability, N staging (N0 or N positive) and M staging (M0 or M1). Based on the above indices, the resectability of the tumour was determined according to a five-point scale. Clinical, operative, and pathological findings were used as a reference standard to compare the diagnostic performance of the two imaging sets via the McNemar test. RESULTS: The diagnostic performance of [68Ga]Ga-DOTA-FAPI-04 PET/MR imaging was not significantly different from that of [18F]-FDG PET/CT plus CECT imaging in the assessment of tumour resectability (area under the receiver operating characteristic curve: 0.854 vs. 0.775, p = 0.192), N staging [accuracy: 82.4% (14 of 17 patients) vs. 58.8% (10 of 17 patients), p = 0.125] and M staging [accuracy: 100% (31 of 31 patients) vs. 90.3% (28 of 31 patients), p = 0.250]. However, compared with [18F]-FDG PET/CT plus CECT imaging, [68Ga]Ga-DOTA-FAPI-04 PET/MR imaging changed the M stage in three patients by upstaging from M0 to M1 in 2 patients and downstaging from M1 to M0 in 2 patients. In 13 patients with liver metastases, the number of liver metastases detected via [68Ga]Ga-DOTA-FAPI-04 PET/MR imaging was greater than that detected via [18F]-FDG PET/CT plus CECT imaging (324 vs. 240). In 3 patients with peritoneal metastases, [68Ga]Ga-DOTA-FAPI-04 PET/MR imaging detected more peritoneal metastases than did [18F]-FDG PET/CT plus CECT imaging. CONCLUSIONS: [68Ga]Ga-DOTA-FAPI-04 PET/MR imaging has diagnostic accuracy comparable to [18F]-FDG PET/CT plus CECT in terms of preoperative staging and assessment of resectability in pancreatic cancer; additionally, it exhibits superior capability in detecting liver and peritoneal metastases. Consequently, [68Ga]Ga-DOTA-FAPI-04 PET/MR has the potential to become a one-stop imaging tool for the preoperative evaluation of pancreatic cancer.
引用
- Zhang Z, Guo S, Su W, et al. Preoperative assessment of pancreatic cancer with [68Ga]Ga-DOTA-FAPI-04 PET/MR versus [18F]-FDG PET/CT plus contrast-enhanced CT: a prospective preliminary study. Eur J Nucl Med Mol Imaging. 2024. PMID: 39508900. doi:10.1007/s00259-024-06943-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。