快速与缓慢铷-82输注方案及当代三维心脏模拟正电子发射断层扫描-计算机断层扫描心肌灌注的重复测试精密度

Fast vs slow rubidium-82 infusion profiles and test-retest precision of myocardial perfusion using contemporary 3D cardiac analog positron emission tomography-computed tomography imaging.
PubMed 文献 · J Nucl Cardiol · 2024-10-18

研究纳入98名受试者(健康志愿者、临床患者及透壁心肌梗死患者),在模拟三维PET-CT上随机接受50 mL/min(快速)与20 mL/min(缓慢)铷-82输注方案,比较静息与负荷心肌血流量、重复测试精密度及图像质量。结果显示两种方案的定量灌注指标与图像质量无临床显著差异,快速与缓慢方案的重复测试精密度相似(COV 11.5% vs 11.3%,P=.77)。

要点

  • 快速与缓慢铷-82输注方案的静息和负荷心肌血流量高度相关(ICC分别为.91-.93和.97)。
  • 同日重复测试精密度相似:COV 11.5% vs 11.3%(P=.77),RC 21.5% vs 22.6%(快速 vs 缓慢)。
  • 两种输注方案的心肌血流量值与图像质量指标均无临床显著差异。

核心结论

  • 在当代模拟三维PET-CT上,铷-82快速与缓慢输注在精密度、灌注指标或图像质量方面无临床显著差异。

研究设计与样本

  • 研究纳入98名来自3个不同组的志愿者:健康志愿者(Normals)、有危险因素和/或冠心病的患者(Clinicals)以及既往透壁心肌梗死患者(Infarcts)。
  • 受试者在模拟三维PET-CT上接受心脏负荷测试,接受3次连续静息扫描和2次连续负荷扫描,扫描间隔数分钟,随机分配两种铷-82输注方案:50 mL/min(快速[F])和20 mL/min(缓慢[S])。
  • 使用HeartSee软件计算灌注指标(静息心肌血流量[rMBF]和负荷心肌血流量[sMBF]),并比较方差系数(COV)、重复性(RC)、MBF和图像质量指标。

主要发现

  • 快速与缓慢方案的rMBF相关性良好,组内相关系数(ICC)范围为.91-.93。
  • 快速与缓慢方案的sMBF高度相关(ICC=.97)。
  • 快速与缓慢方案的同日重复测试精密度相似:COV 11.5% vs 11.3%(P=.77);RC 21.5% vs 22.6%(快速-快速 vs 缓慢-缓慢)。
  • 快速与缓慢方案之间的MBF值无临床显著差异。
  • 两种方案的图像质量指标相似。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: On legacy 2D positron emission tomography (PET) systems utilizing a 50 mL/min Rb-82 profile, test-retest precision of quantitative perfusion is ∼10%. It is unclear whether Rb-82 infusion rate significantly impacts quantitative perfusion and/or image quality on modern analog 3D PET-CT systems. We aimed to determine whether the Rb-82 infusion profile significantly impacts test-retest precision of quantitative perfusion, perfusion metrics, and/or image quality on a modern analog 3D PET-CT scanner. METHODS: Ninety-eight volunteers from 3 distinct groups: healthy volunteers (Normals), patients with risk factors, and/or coronary disease (Clinicals) and patients with prior transmural myocardial infarctions (Infarcts), underwent cardiac stress testing on an analog 3D PET-CT. Participants received 3 consecutive resting scans and 2 consecutive stress scans, minutes apart, with two randomly assigned Rb-82 infusion profiles: 50 mL/min (fast [F]) and 20 mL/min (slow [S]). Perfusion metrics (resting (rMBF) and stress myocardial blood flow (sMBF)) were calculated using HeartSee software. Coefficients of variance (COV), repeatability (RC), MBF, and image quality metrics were compared. RESULTS: rMBF correlated well between F and S profiles, with intraclass correlation coefficients (ICC) ranging .91-.93. sMBF was highly correlated between F and S profiles (ICC = .97). Fast and slow profiles were associated with similar same-day test-retest precision (COV 11.5% vs 11.3% (P = .77); RC 21.5% vs 22.6%, for F-F vs S-S). There were no clinically significant differences in MBF values between F and S profiles. Image quality metrics were similar between the 2 profiles. CONCLUSIONS: There are no clinically significant differences in precision, perfusion metrics, or image quality between Rb-82 fast and slow infusions using a contemporary analog 3D PET-CT.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Bober RM, Milani RV, Abelhad NI, et al. Fast vs slow rubidium-82 infusion profiles and test-retest precision of myocardial perfusion using contemporary 3D cardiac analog positron emission tomography-computed tomography imaging. J Nucl Cardiol. 2024. PMID: 39426501. doi:10.1016/j.nuclcard.2024.102059