文献速递肿瘤 PET/CT

Ki图像与SUV图像在PET/CT显像中病灶检测的获益比较

Comparative benefits of Ki and SUV images in lesion detection during PET/CT imaging.
PubMed 文献 · EJNMMI Res · 2024-10-16

该回顾性研究纳入134例患者共244个经病理证实的病灶(200个恶性、44个良性),比较Ki图像与SUV图像在病灶检测中的表现。Ki图像与SUV图像的病灶检出率分别为99.5%(218/219)与97.7%(214/219)(p = .22),敏感性、特异性、准确性、阳性预测值、阴性预测值及曲线下面积均相似(均p ≥ .10)。结论认为Ki图像在病灶检测方面较SUV图像有获益,尤其在高背景器官如肝脏。

要点

  • Ki图像病灶检出率99.5%(218/219)vs SUV图像97.7%(214/219),差异无统计学显著(p = .22)。
  • SUV图像上5个假阴性病灶在Ki图像上为真阳性,包括3个肝脏恶性肿瘤和2个转移性淋巴结。
  • 敏感性94.0% vs 96.0%、特异性41.9% vs 41.9%、准确性84.4% vs 86.1%,均无显著差异(均p ≥ .10)。

核心结论

  • Ki图像在病灶检测方面较SUV图像有获益,尤其在高背景器官如肝脏。
  • 作者建议采用Ki成像增强的对比度以在临床中提高此类病例的检出率。

研究设计与样本

  • 回顾性研究,纳入134例患者共244个经病理证实的病灶(200个恶性、44个良性)。
  • 患者接受基于体重的18F-FDG注射,行60分钟全身PET/CT动态显像;SUV图像用扫描最后10分钟数据重建,Ki图像用第12–60分钟数据经Patlak方法生成。

主要发现

  • 病灶检出率:SUV图像97.7%(214/219)vs Ki图像99.5%(218/219)(p = .22)。
  • SUV图像上5个假阴性病灶在Ki图像上为真阳性(3个肝脏恶性肿瘤、2个转移性淋巴结)。
  • 敏感性:SUV图像94.0% vs Ki图像96.0%(p = .22);特异性:SUV图像41.9% vs Ki图像41.9%(p > .99)。
  • 准确性:SUV图像84.4% vs Ki图像86.1%(p = .61);阳性预测值:SUV图像87.9% vs Ki图像88.1%(p = .94);阴性预测值:SUV图像60.0% vs Ki图像69.2%(p = .47)。
  • 曲线下面积:SUV图像0.68(95%CI 0.61–0.73)vs Ki图像0.69(95%CI 0.62–0.74)(均p ≥ .10)。

临床怎么用

  • 作者建议采用Ki成像增强的对比度,以在临床中提高高背景器官如肝脏病灶的检出率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Clinical application of the tracer net influx rate (Ki) imaging in PET/CT remains limited, due to a lack of evidence demonstrating the superiority of Ki images in lesion detection, and guidelines on when to utilize Ki images. This study aims to compare the benefits of Ki and standardized uptake value (SUV) images in lesion detection during PET/CT imaging. By analyzing the performance of both techniques in identifying tumor lesions, the study seeks to provide guidance for the clinical application of Ki images. RESULTS: This retrospective study included 134 patients with 244 pathologically confirmed lesions (200 malignant and 44 benign). Patients with a histopathological diagnosis received a weight-based 18F-FDG injection and underwent 60-min total-body PET/CT dynamic imaging. SUV images were reconstructed using data collected from the last 10 min of the scans. Ki images were generated using the Patlak methods with data from minutes 12-60. The background SUVmax, SUVmean, SUVSD, Kimax, Kimean, and KiSD values were recorded. The signal-to-noise ratios of the SUV (SUVSNR) and Ki (KiSNR) images were calculated. The lesion detection rate and sensitivity of the SUV and Ki images were evaluated. The lesion-detection rates were 97.7% (214/219) and 99.5% (218/219) for the SUV and Ki images, respectively (p = .22). Five false-negative lesions on the SUV images were true-positive on the Ki images (3 hepatic malignancies and 2 metastatic lymph nodes). The sensitivity (94.0% vs. 96.0%, p = .22), specificity (41.9% vs. 41.9%, p > .99), accuracy (84.4% vs. 86.1%, p = .61), positive predictive value (87.9% vs. 88.1%, p = .94), negative predictive value (60.0% vs. 69.2%, p = .47), and the area under the curve [0.68 (95% confidence interval, 0.61-0.73) vs. 0.69 (95% confidence interval, 0.62-0.74)] were similar in the SUV and Ki images (all p ≥ .10). CONCLUSION: Ki images exhibit benefits in lesion detection compared to SUV images, particularly in organs with high background such as liver. The enhanced contrast provided by Ki imaging is recommended to clinically improve detection rates in such cases.

来源:EJNMMI Res,查看原文。版权归原作者所有。