文献速递肿瘤 PET/CT

不同参数Patlak成像方法的影响及与长轴视野(LAFOV)PET/CT两组织房室药代动力学模型的比较在肿瘤患者中的应用

Impact of different parametric Patlak imaging approaches and comparison with a 2-tissue compartment pharmacokinetic model with a long axial field-of-view (LAFOV) PET/CT in oncological patients.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2024-09-11

研究纳入50例肿瘤患者共346个肿瘤病灶,比较直接与间接Patlak成像及不同时间窗计算的Patlak Ki图像,并与2TCM模型比较。结果显示Patlak Ki图像病灶对比度优于SUV图像,但未提高病灶检出率;Patlak成像时间窗比直接或间接方法更重要。

要点

  • Patlak Ki图像病灶对比度优于SUV图像,但未提高肿瘤病灶检出率。
  • Patlak成像所用时间窗比直接或间接计算方法影响更大。
  • Patlak与2TCM模型联合可能有助于未来全身参数成像获得最佳TBR。

核心结论

  • 动态[18F]FDG LAFOV PET/CT产生的Patlak Ki图像病灶对比度优于SUV图像,但未提高病灶检出率。
  • Patlak成像所用时间窗比直接或间接方法发挥更重要的作用。
  • 作者认为,未来联合不同模型(如Patlak与2TCM)可能有助于参数成像获得全身最佳TBR。

研究设计与样本

  • 研究纳入50例肿瘤患者共346个肿瘤病灶,均行[18F]FDG PET/CT(颅顶至大腿上部)。
  • 以降主动脉获得的图像衍生输入函数(IDIF)作为唯一输入函数。
  • 比较四组图像:短时间(30分钟)直接法(STD)Patlak Ki、短时间(30分钟)间接法(STI)Patlak Ki、长时间(59.25分钟)间接法(LTI)Patlak Ki及50-60分钟SUV(sumSUV)。
  • 采用基于VOI的2TCM评估肿瘤病灶与正常组织,并与Patlak模型结果比较。

主要发现

  • 四种方法在肿瘤病灶数量上无显著差异。
  • 发现3例不一致结果:一例肝病灶在所有Patlak Ki图像均为真阳性;一例肝病灶仅在LTI Ki delineated为假阳性,MRI证实为血管瘤;一例肺肿瘤旁肺不张患者为真阴性示例。
  • STD、STI和LTI Ki图像的TBR分别较sumSUV图像高2.9倍、3.3倍和4.3倍。
  • LTI Ki的TBR显著高于STD Ki。
  • 基于VOI的k3的TBR较sumSUV高21倍。

关键数值与推荐

  • Patlak Ki在正常肺组织的鉴别能力更好,2TCM k3在正常肝脏的鉴别能力更好。
  • 2TCM Ki与LTI Patlak Ki在肿瘤病灶组相关性最高(r=0.95)。
  • 2TCM Ki与STD Patlak Ki在全组织组和正常组织组相关性最高(分别为r=0.93和r=0.74)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: The recently introduced Long-Axial-Field-of-View (LAFOV) PET-CT scanners allow for the first-time whole-body dynamic- and parametric imaging. Primary aim of this study was the comparison of direct and indirect Patlak imaging as well as the comparison of different time frames for Patlak calculation with the LAFOV PET-CT in oncological patients. Secondary aims of the study were lesion detectability and comparison of Patlak analysis with a two-tissue-compartment model (2TCM). METHODOLOGY: 50 oncological patients with 346 tumor lesions were enrolled in the study. All patients underwent [18F]FDG PET/CT (skull to upper thigh). Here, the Image-Derived-Input-Function) (IDIF) from the descending aorta was used as the exclusive input function. Four sets of images have been reviewed visually and evaluated quantitatively using the target-to-background (TBR) and contrast-to-noise ratio (CNR): short-time (30 min)-direct (STD) Patlak Ki, short-time (30 min)-indirect (STI) Patlak Ki, long-time (59.25 min)-indirect (LTI) Patlak Ki, and 50-60 min SUV (sumSUV). VOI-based 2TCM was used for the evaluation of tumor lesions and normal tissues and compared with the results of Patlak model. RESULTS: No significant differences were observed between the four approaches regarding the number of tumor lesions. However, we found three discordant results: a true positive liver lesion in all Patlak Ki images, a false positive liver lesion delineated only in LTI Ki which was a hemangioma according to MRI and a true negative example in a patient with an atelectasis next to a lung tumor. STD, STI and LTI Ki images had superior TBR in comparison with sumSUV images (2.9-, 3.3- and 4.3-fold higher respectively). TBR of LTI Ki were significantly higher than STD Ki. VOI-based k3 showed a 21-fold higher TBR than sumSUV. Parameters of different models vary in their differential capability between tumor lesions and normal tissue like Patlak Ki which was better in normal lung and 2TCM k3 which was better in normal liver. 2TCM Ki revealed the highest correlation (r = 0.95) with the LTI Patlak Ki in tumor lesions group and demonstrated the highest correlation with the STD Patlak Ki in all tissues group and normal tissues group (r = 0.93 and r = 0.74 respectively). CONCLUSIONS: Dynamic [18F]-FDG with the new LAFOV PET/CT scanner produces Patlak Ki images with better lesion contrast than SUV images, but does not increase the lesion detection rate. The time window used for Patlak imaging plays a more important role than the direct or indirect method. A combination of different models, like Patlak and 2TCM may be helpful in parametric imaging to obtain the best TBR in the whole body in future.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Pan L, Sachpekidis C, Hassel J, et al. Impact of different parametric Patlak imaging approaches and comparison with a 2-tissue compartment pharmacokinetic model with a long axial field-of-view (LAFOV) PET/CT in oncological patients. Eur J Nucl Med Mol Imaging. 2024. PMID: 39256215. doi:10.1007/s00259-024-06879-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。