文献速递肿瘤 PET/CT神经核医学

18F-FDG PET/CT检测免疫治疗诱导性垂体炎——病例对照研究

18 F-FDG PET/CT for Detection of Immunotherapy-Induced Hypophysitis-A Case-Control Study.
PubMed 文献 · Clin Nucl Med · 2024-09-25

本研究纳入28例转移性黑色素瘤患者,评估FDG PET/CT垂体靶本比(TBR)对免疫检查点抑制剂诱导性垂体炎的诊断准确性。在诊断前50天至后8天内行PET/CT的11例患者中,垂体炎组TBR显著高于对照组(中位数2.78 vs 1.59,P=0.034),TBR阈值2.41时灵敏度72.7%、特异度90.9%(AUC=0.769)。结论提示TBR约2.4可能提示即将发生的垂体炎。

要点

  • 垂体炎组TBR中位数2.78,显著高于对照组1.59(P=0.034)。
  • TBR阈值2.41时灵敏度72.7%、特异度90.9%,AUC=0.769。
  • TBR分布视觉评估与诊断时间缩短呈正相关。

核心结论

  • 在转移性黑色素瘤接受ICI治疗的患者中,垂体TBR约2.4可能提示即将发生的ICI诱导性垂体炎。

研究设计与样本

  • 病例对照研究,纳入28例患者,比较14例ICI诱导性垂体炎患者与年龄性别匹配的无垂体炎对照。
  • 垂体炎患者需在诊断前90天至后10天内行FDG PET/CT,对照为接受ICI治疗无垂体炎体征者。
  • 计算垂体SUVmax与血池SUVmean比值(靶本比TBR),用ROC曲线分析诊断准确性。

主要发现

  • 垂体炎患者多数接受伊匹木单抗/纳武利尤单抗治疗(64.3%,9/14)。
  • 仅纳入诊断前50天至后8天内行PET/CT的11/14例垂体炎患者进行分析,其TBR显著高于对照组(中位数[四分位距]2.78[2.41] vs 1.59[0.70],P=0.034)。
  • TBR阈值2.41时灵敏度72.7%、特异度90.9%,AUC=0.769。
  • TBR分布的视觉评估显示与诊断时间缩短呈正相关。

关键数值与推荐

  • TBR阈值2.41:灵敏度72.7%,特异度90.9%,AUC=0.769。
  • 垂体炎组TBR中位数2.78(四分位距2.41),对照组1.59(四分位距0.70),P=0.034。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Hypophysitis occurs in up to 10% of patients treated with immune-checkpoint inhibitors (ICIs). MRI shows no abnormalities of the pituitary gland in one third of patients. A delayed diagnosis increases the risk for life-threatening adrenal crisis, underscoring the need for early detection. This study evaluates the diagnostic accuracy FDG PET/CT in detecting ICI-induced hypophysitis in a cohort of melanoma patients. MATERIALS AND METHODS: Patients with metastatic melanoma and ICI-induced hypophysitis, who underwent FDG PET/CT 90 days before to 10 days after diagnosis, were compared with an age- and sex-matched control group of patients undergoing ICI treatment without signs of hypophysitis. The ratio of SUV max of the pituitary gland to the SUV mean of the blood pool (target-to-background ratio [TBR]) was calculated. Diagnostic accuracy of the TBR was assessed using area under the receiver operating characteristics curve analysis. RESULTS: A total of 28 patients was included. The majority of patients with hypophysitis received ipilimumab/nivolumab (64.3%, 9/14). Visual assessment of the TBR distribution demonstrated a positive correlation with decreasing time to diagnosis. To evaluate diagnostic performance, only patients with FDG PET/CT 50 days before to 8 days after diagnosis (11/14) were included. TBR was significantly higher in these compared with the control group (median [interquartile range], 2.78 [2.41] vs 1.59 [0.70], respectively; P = 0.034). A sensitivity of 72.7% and a specificity of 90.9% were achieved at a TBR threshold of 2.41 (area under the receiver operating characteristics curve = 0.769). CONCLUSIONS: Our findings suggest that, in patients undergoing ICI treatment for metastatic melanoma, a pituitary TBR of approximately 2.4 may indicate impending ICI-induced hypophysitis.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Fischer A, Martínez-Gómez JM, Mangana J, et al. 18 F-FDG PET/CT for Detection of Immunotherapy-Induced Hypophysitis-A Case-Control Study. Clin Nucl Med. 2024. PMID: 39325145. doi:10.1097/RLU.0000000000005440

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。