文献速递骨显像与常规 SPECT

骨质疏松症中利用定量骨SPECT/CT的容积密度校正标准化摄取值评估骨转换

Imaging bone turnover assessment through volumetric density-adjusted standardized uptake value using quantitative bone SPECT/CT in osteoporosis.
PubMed 文献 · EJNMMI Res · 2024-08-25

本研究纳入55例绝经后韩国女性的177个腰椎,利用[99mTc]Tc-DPD定量骨SPECT/CT计算容积密度校正的SUVmean(dSUVmean)。dSUVmean与容积骨密度(vBMD)呈负相关(ρ=-0.66,p<0.001)。有主要骨质疏松性骨折者vBMD较低而dSUVmean较高,提示低骨量与高骨转换相关。

要点

  • dSUVmean由SUVmean除以vBMD再乘以1,000计算得出。
  • SUVmean与vBMD正相关(r=0.60,p<0.001),dSUVmean与vBMD负相关(ρ=-0.66,p<0.001)。
  • 有骨折者vBMD 62.5±29.4 vs 无骨折者92.3±27.4 mg/cm³(p=0.001),dSUVmean 100.8±60.7 vs 62.6±17.5(p=0.001)。

核心结论

  • 容积密度校正的定量骨SPECT/CT提供了一种新的影像衍生骨转换标志物用于评估骨质疏松症中的骨转换。
  • 该方法可在单个椎体水平精确评估脆性,可能有助于个体化骨质疏松管理。

研究设计与样本

  • 回顾性研究,纳入55例绝经后韩国女性的177个腰椎。
  • 在每个椎体骨小梁部分2 cm³感兴趣区内,用定量SPECT和CT测定SUVmean(g/cm³)与vBMD(mg/cm³)。
  • dSUVmean计算方式为SUVmean除以vBMD再乘以1,000。

主要发现

  • SUVmean与vBMD正相关(r=0.60,p<0.001)。
  • dSUVmean与vBMD负相关(ρ=-0.66,p<0.001),显示密度校正后骨量与骨转换呈反向关系。
  • 有主要骨质疏松性骨折者vBMD为62.5±29.4 mg/cm³,无骨折者为92.3±27.4 mg/cm³(p=0.001)。
  • 有主要骨质疏松性骨折者dSUVmean为100.8±60.7,无骨折者为62.6±17.5(p=0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Serum bone turnover markers offer limited insight into metabolic activity at the individual vertebra level in osteoporosis. This study introduces a novel image-derived bone turnover marker for individual vertebrae to address this limitation, utilizing volumetric density-adjusted quantitative bone single-photon emission computed tomography/computed tomography (SPECT/CT) with [99mTc]Tc-DPD. This retrospective study included 177 lumbar vertebrae from 55 postmenopausal South Korean women. The mean standardized uptake value (SUVmean, g/cm3) and volumetric bone mineral density (vBMD, mg/cm3) were determined within a 2-cm³ volume of interest in the trabecular portion of each vertebra using quantitative SPECT and CT. The density-adjusted mean standardized uptake value (dSUVmean) was calculated by dividing the SUVmean by the vBMD and multiplying by 1,000. RESULTS: SUVmean correlated positively with vBMD (r = 0.60, p < 0.001). Conversely, dSUVmean correlated negatively with vBMD (ρ = -0.66, p < 0.001), highlighting the inverse relationship between bone mass and turnover after density adjustment of SUVmean. Patients with major osteoporotic fractures had lower vBMD (62.5 ± 29.4 vs. 92.3 ± 27.4 mg/cm³, p = 0.001) but higher dSUVmean (100.8 ± 60.7 vs. 62.6 ± 17.5, p = 0.001) compared to those without fractures, reinforcing the association between fracture prevalence, low bone mass, and high bone turnover. CONCLUSION: Volumetric density-adjusted quantitative bone SPECT/CT offers a novel image-derived bone turnover marker for assessing bone turnover in osteoporosis. This method provides a precise assessment of fragility at the individual vertebra level, which may enhance personalized osteoporosis management.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Lee DY, Oh JS, Kim JW, et al. Imaging bone turnover assessment through volumetric density-adjusted standardized uptake value using quantitative bone SPECT/CT in osteoporosis. EJNMMI Res. 2024. PMID: 39182210. doi:10.1186/s13550-024-01137-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。