PubMed 文献 · J Nucl Cardiol · 2024-07-27

本研究纳入44例疑似感染性心内膜炎患者,比较专用心脏采集方案(DCP)与传统全身采集方案(WBA)在数字[18F]-FDG-PET/CT上的诊断准确性,并由3名顾问医师和受训医师盲法判读。DCP对自体瓣膜心内膜炎的灵敏度、特异度和准确度分别为89%、93%和91%,对人工瓣膜心内膜炎分别为93%、86%和91%;DCP较WBA对自体瓣膜心内膜炎的诊断性能有明显提升,在受训医师中尤为明显,但不及顾问医师。

要点

  • DCP对自体瓣膜心内膜炎的灵敏度89%、特异度93%、准确度91%。
  • DCP对人工瓣膜心内膜炎的灵敏度93%、特异度86%、准确度91%。
  • DCP较WBA对自体瓣膜心内膜炎诊断性能提升在受训医师中尤为明显。

核心结论

  • 使用DCP的数字FDG-PET/CT可提高疑似感染性心内膜炎尤其是自体瓣膜心内膜炎的诊断准确性,前提是判读者具备必要的专业水平。
  • 这些发现可能对感染性心内膜炎相关的发病率、死亡率和患者管理产生重要影响,并可能对更新关于FDG PET/CT在自体瓣膜心内膜炎中价值的现有观点有意义。

研究设计与样本

  • 44例疑似感染性心内膜炎患者在接受隔夜禁食后行数字FDG-PET/CT检查。
  • 3名顾问医师和受训医师在不知晓采集方案和临床信息的情况下盲法判读PET图像,进行视觉和半定量分析。

主要发现

  • DCP对自体瓣膜心内膜炎的灵敏度89%、特异度93%、准确度91%。
  • DCP对人工瓣膜心内膜炎的灵敏度93%、特异度86%、准确度91%。
  • 与WBA相比,DCP对自体瓣膜心内膜炎的诊断性能有明显提升,在受训医师中尤为明显,但不及顾问医师。
  • 数字FDG-PET/CT使79.5%的改良Duke临床标准(mDC)重新分类,其中34.1%升级、45.4%降级。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to assess the impact of dedicated cardiac protocol (DCP) on diagnostic accuracy of state-of-the-art digital [18F]-FDG-PET/CT in infective endocarditis (IE) and the intra-individual comparison of the performance with that of conventional whole-body approach (WBA) and to analyze the effects of the expertise level of the investigators. METHODS: 44 patients suspected for IE underwent digital-FDG-PET/CT after overnight fasting. Each three consultants and trainees reread PET images blinded to the examination approach and clinical information. Visual and semiquantitative analyses were performed. RESULTS: Digital-FDG-PET/CT with DCP revealed sensitivity, specificity, and accuracy of 89%, 93%, and 91% for native valve endocarditis (NVE) and 93%, 86%, and 91% for prosthetic valve endocarditis. Compared to WBA, substantial improvement of the diagnostic performance for NVE in DCP was evident, especially in trainees, but not as high compared to consultants. Digital-FDG-PET/CT enabled 79.5% reclassification of modified-Duke-Clinical-Criteria (mDC) with 34.1% upgrading and 45.4% downgrading. CONCLUSIONS: This study provides new data using state-of-the-art digital-FDG-PET/CT with DCP improving the diagnostic accuracy in challenging cases of possible IE, particularly in NVE, provided that the investigators involved have the necessary expertise. These findings may have a significant impact on IE-related morbidity, mortality, and patient's management and might be meaningful for updates on the prevailing opinion regarding the value of FDG PET/CT in NVE.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Notohamiprodjo S, Scheidhauer K, Eiber M, et al. Impact of a dedicated cardiac protocol on diagnosis of infective endocarditis in patients undergoing [18F]-FDG-thoracic digital-PET/CT - Effects of expertise level. J Nucl Cardiol. 2024. PMID: 39074602. doi:10.1016/j.nuclcard.2024.102010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。