自身免疫性甲状腺炎患者中[68Ga]Ga-FAPI与2-[18F]FDG PET/CT的病例对照研究
该病例对照研究比较了自身免疫性甲状腺炎(AIT)患者在[68Ga]Ga-FAPI PET与2-[18F]FDG PET上的甲状腺摄取情况。2019年9月至2021年7月,6例AIT患者[68Ga]Ga-FAPI PET显示甲状腺摄取视觉增高,其FAP表达与葡萄糖代谢均显著高于匹配的健康对照组;但[68Ga]Ga-FAPI与2-[18F]FDG PET之间的中位摄取无显著差异。
要点
- AIT患者[68Ga]Ga-FAPI PET可见甲状腺摄取增高,是判读FAPI PET时需注意的陷阱。
- AIT患者甲状腺FAP表达与葡萄糖代谢均显著高于健康对照组。
- 同一AIT患者中,[68Ga]Ga-FAPI与2-[18F]FDG PET的甲状腺中位摄取无显著差异。
核心结论
- AIT患者甲状腺在[68Ga]Ga-FAPI与2-[18F]FDG PET上均显示摄取增高。
- 甲状腺偶然摄取是[68Ga]Ga-FAPI PET判读的另一陷阱,应促使进行临床检查。
研究设计与样本
- 病例对照研究,比较[68Ga]Ga-FAPI PET甲状腺病理性摄取阳性的AIT患者与健康对照组。
- 2019年9月至2021年7月,6例患者[68Ga]Ga-FAPI PET显示甲状腺摄取视觉增高且TBR增高,回顾性临床检查均确诊或已知AIT。
主要发现
- 与匹配的健康对照组相比,AIT组[68Ga]Ga-FAPI SUVpeak为7.0 vs 1.7(p=0.004),TBRbloodpool为6.8 vs 1.7(p=0.002)。
- 与匹配的健康对照组相比,AIT组2-[18F]FDG SUVpeak为3.9 vs 1.4(p=0.004),TBRbloodpool为4.0 vs 1.2(p=0.041)。
- [68Ga]Ga-FAPI与2-[18F]FDG PET之间的甲状腺中位摄取无显著差异(SUVpeak:7.3 vs 5.6;p=0.104)。
局限性
- 本研究为回顾性临床检查。
- AIT组仅纳入6例患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Radiolabelled fibroblast activation protein inhibitors (FAPIs) are becoming increasingly important for imaging various tumour diseases. However, it is essential to be aware of potential pitfalls. Here, we investigate FAP expression in the thyroid gland in autoimmune thyroiditis (AIT). METHODS: AIT patients with pathological thyroid uptake on [68Ga]Ga-FAPI PET were compared with glucose metabolism on 2-[18F]FDG PET in terms of SUVmax/SUVpeak/SUVmean/tissue-to-background ratio (TBR), and with a healthy control group. RESULTS: Between September 2019 and July 2021, 6 patients presented with a visually increased thyroid uptake and TBR on [68Ga]Ga-FAPI PET. In the retrospective clinical work-up, all patients had known or newly diagnosed AIT. Compared to a matched healthy control group, FAP expression and glucose metabolism were significantly increased ([68Ga]Ga-FAPI (SUVpeak): 7.0 vs. 1.7; p = 0.004/(TBRbloodpool): 6.8 vs. 1.7; p = 0.002; 2-[18F]FDG (SUVpeak): 3.9 vs. 1.4; p = 0.004/(TBRbloodpool): 4.0 vs. 1.2; p = 0.041). However, there was no significant difference in median uptake between [68Ga]Ga-FAPI and 2-[18F]FDG PET (SUVpeak: 7.3 vs. 5.6; p = 0.104). CONCLUSION: Patients with AIT show higher thyroid uptake on [68Ga]Ga-FAPI and 2-[18F]FDG PET. Incidental thyroid uptake is another pitfall in the interpretation of [68Ga]Ga-FAPI PET and should prompt a clinical work-up.
引用
- Pabst KM, Kessler L, Ferdinandus J, et al. [68Ga]Ga-FAPI versus 2-[18F]FDG PET/CT in patients with autoimmune thyroiditis: a case control study. EJNMMI Res. 2024. PMID: 39023777. doi:10.1186/s13550-024-01129-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。