全身动态PET/CT显像揭示[13N]NH3在正常器官中的动力学分布
研究纳入11名参与者行全身[13N]NH3动态PET,以不可逆双组织室模型拟合时间-活性曲线,获得K1、k2、k3及Ki等动力学参数。结果显示各器官动力学速率差异明显,部分器官存在明显的13N-氨捕获,正常器官动力学参数分布可作为肿瘤显像的参考。
要点
- K1均值从肌肉的0.049 mL/cm3/min到肾脏的2.936 mL/cm3/min不等。
- Ki在心肌最大(0.601±0.259 mL/cm3/min),在骨髓最小(0.028±0.022 mL/cm3/min)。
- 按动力学特征可将器官分为三组,部分器官存在明显的k3即13N-氨捕获。
核心结论
- 各器官[13N]NH3动力学速率存在差异,部分器官有明显的13N-氨捕获。
- 正常器官13N-氨动力学参数的分布可作为其潜在肿瘤显像应用的参考。
研究设计与样本
- 11名参与者接受全身[13N]NH3动态正电子发射断层显像(PET)。
- 在器官内勾画感兴趣区获得时间-活性曲线(TAC),采用不可逆双组织室模型(2TC)拟合获得常数速率K1、k2、k3并计算Ki。
- 另采用全数据单组织室模型(1TCfull)和前四分钟数据单组织室模型(1TC4min)拟合TAC数据。
- 比较不同模型间的K1和k2以评估器官中[13N]NH3的捕获。
主要发现
- K1均值从肌肉的0.049 mL/cm3/min到肾脏的2.936 mL/cm3/min不等。
- k2在肝脏最低(0.001 min-1)、在肾脏最高(0.587 min-1),k3在垂体最低(0.009 min-1)、在肝脏最高(0.800 min-1)。
- Ki在心肌最大(0.601±0.259 mL/cm3/min),在骨髓最小(0.028±0.022 mL/cm3/min)。
- 按动力学特征分为三组:甲状腺、肺、脾、胰腺、肾脏;肝脏与肌肉;皮质、白质、小脑、垂体、腮腺、下颌下腺、心肌、骨与骨髓。
- 多个器官中可识别出明显的k3;2TC与1TCfull之间多个器官K1及多数器官k2有显著变化,而2TC与1TC4min之间K1和k2均相当。
关键数值与推荐
- K1均值范围为0.049 mL/cm3/min(肌肉)至2.936 mL/cm3/min(肾脏)。
- k2最低为肝脏0.001 min-1、最高为肾脏0.587 min-1;k3最低为垂体0.009 min-1、最高为肝脏0.800 min-1。
- Ki最大为心肌0.601±0.259 mL/cm3/min,最小为骨髓0.028±0.022 mL/cm3/min。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To systematically investigate kinetic metrics and metabolic trapping of [13N]NH3 in organs. METHODS: Eleven participants performed total-body [13N]NH3 dynamic positron emission tomography (PET). Regions of interest were drawn in organs to obtain time-to-activity curves (TACs), which were fitted with an irreversible two-tissue compartment model (2TC) to investigate constant rates K1, k2 and k3, and to calculate Ki. Additionally, one-tissue compartment model using full data (1TCfull) and the first four minutes of data (1TC4min) were fitted to TAC data. K1 and k2 were compared among different models to assess [13N]NH3 trapping in organs. RESULTS: Kinetic rates of [13N]NH3 varied significantly among organs. The mean K1 ranged from 0.049 mL/cm3/min in the muscle to 2.936 mL/cm3/min in the kidney. The k2 and k3 were lowest in the liver (0.001 min- 1) and in the pituitary (0.009 min- 1), while highest in the kidney (0.587 min- 1) and in the liver (0.800 min- 1), respectively. The Ki was largest in the myocardium (0.601 ± 0.259 mL/cm3/min) while smallest in the bone marrow (0.028 ± 0.022 mL/cm3/min). Three groups of organs with similar kinetic characteristics were revealed: (1) the thyroid, the lung, the spleen, the pancreas, and the kidney; (2) the liver and the muscle; and (3) the cortex, the white matter, the cerebellum, the pituitary, the parotid, the submandibular gland, the myocardium, the bone, and the bone marrow. Obvious k3 was identified in multiple organs, and significant changes of K1 in multiple organs and k2 in most organs were found between 2TC and 1TCfull, but both K1 and k2 were comparable between 2TC and 1TC4min. CONCLUSION: The kinetic rates of [13N]NH3 differed among organs with some have obvious 13N-anmmonia trapping. The normal distribution of kinetic metrics of 13N-anmmonia in organs can serve as a reference for its potential use in tumor imaging.
引用
- Liu G, Gu T, Chen S, et al. Total-body dynamic PET/CT imaging reveals kinetic distribution of [13N]NH3 in normal organs. Eur J Nucl Med Mol Imaging. 2024. PMID: 38976037. doi:10.1007/s00259-024-06826-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。