SPECT显像在疑似肺栓塞患者中的诊断准确性:系统评价与网状Meta分析
该系统评价与网状Meta分析检索Medline、Embase和Cochrane数据库截至2023年10月的文献,纳入24篇文章(总n=6576),评估肺SPECT与平面显像对疑似急性肺栓塞或慢性血栓栓塞性肺动脉高压的诊断准确性。结果显示SPECT诊断性能优于平面显像,V/Q SPECT/CT为最准确模态。
要点
- 疑似急性肺栓塞中,V/Q SPECT/CT灵敏度0.97、特异度0.98,为最准确模态。
- SPECT较平面显像的相对灵敏度1.17(95%CI 1.06-1.30,P<0.001)、相对特异度1.14(95%CI 1.00-1.29,P=0.05)。
- 疑似慢性血栓栓塞性肺动脉高压中,SPECT汇总灵敏度0.97、特异度0.91。
核心结论
- SPECT对肺栓塞表现出更优的诊断性能,V/Q SPECT/CT为最准确模态。
研究设计与样本
- 系统评价与网状Meta分析,检索Medline、Embase和Cochrane数据库截至2023年10月前发表的文章,纳入24篇文章(总n=6576)。
- Meta分析评估 perfusion(Q)SPECT、ventilation(V)/Q SPECT、Q SPECT/CT和V/Q SPECT/CT的诊断准确性,网状Meta分析在配对设计研究中比较SPECT与平面显像。
主要发现
- 疑似急性肺栓塞:Q SPECT灵敏度0.93(95%CI 0.87-0.99;I²=49%)、特异度0.72(95%CI 0.54-0.95;I²=94%)。
- 疑似急性肺栓塞:V/Q SPECT灵敏度0.96(95%CI 0.94-0.98;I²=51%)、特异度0.95(95%CI 0.92-0.98;I²=80%)。
- 疑似急性肺栓塞:Q SPECT/CT灵敏度0.93(95%CI 0.87-0.98;I²=66%)、特异度0.82(95%CI 0.70-0.96;I²=87%)。
- 疑似急性肺栓塞:V/Q SPECT/CT灵敏度0.97(95%CI 0.93-1.00;I²=7%)、特异度0.98(95%CI 0.97-1.00;I²=31%)。
- SPECT较平面显像的相对灵敏度1.17(95%CI 1.06-1.30;P<0.001)、相对特异度1.14(95%CI 1.00-1.29;P=0.05);疑似慢性血栓栓塞性肺动脉高压中SPECT汇总灵敏度0.97(95%CI 0.95-1.00;I²=0%)、特异度0.91(95%CI 0.87-0.94;I²=0%)。
关键数值与推荐
- 疑似急性肺栓塞中V/Q SPECT/CT灵敏度0.97(95%CI 0.93-1.00;I²=7%)、特异度0.98(95%CI 0.97-1.00;I²=31%),为最准确模态。
- SPECT较平面显像相对灵敏度1.17(95%CI 1.06-1.30;P<0.001)、相对特异度1.14(95%CI 1.00-1.29;P=0.05)。
- 疑似慢性血栓栓塞性肺动脉高压中SPECT汇总灵敏度0.97(95%CI 0.95-1.00;I²=0%)、特异度0.91(95%CI 0.87-0.94;I²=0%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This meta-analysis and systematic review assessed the diagnostic accuracy of lung SPECT compared with lung planar imaging in patients with suspected acute pulmonary embolism (PE) or chronic thromboembolic pulmonary hypertension. PATIENTS AND METHODS: A search of Medline, Embase, and Cochrane databases identified suitable articles published before October 2023. Meta-analyses were performed to determine the diagnostic accuracy of SPECT imaging modalities, including perfusion (Q) SPECT, ventilation (V)/Q SPECT, Q SPECT/CT, and V/Q SPECT/CT. Network meta-analyses were performed to compare the diagnostic accuracy of SPECT and planar imaging in paired-design studies. RESULTS: Twenty-four articles (total n = 6576) were included in the analysis. For suspected acute PE, the respective sensitivity and specificity of SPECT imaging modalities were as follows: Q SPECT, 0.93 (95% confidence interval [CI], 0.87-0.99; I2 = 49%) and 0.72 (95% CI, 0.54-0.95; I2 = 94%); V/Q SPECT, 0.96 (95% CI, 0.94-0.98; I2 = 51%) and 0.95 (95% CI, 0.92-0.98; I2 = 80%); Q SPECT/CT, 0.93 (95% CI, 0.87-0.98; I2 = 66%) and 0.82 (95% CI, 0.70-0.96; I2 = 87%); and V/Q SPECT/CT, 0.97 (95% CI, 0.93-1.00; I2 = 7%) and 0.98 (95% CI, 0.97-1.00; I2 = 31%). The relative sensitivity and specificity of SPECT compared with planar imaging were 1.17 (95% CI, 1.06-1.30; P < 0.001) and 1.14 (95% CI, 1.00-1.29; P = 0.05), respectively. For suspected chronic thromboembolic pulmonary hypertension, the pooled sensitivity and specificity of SPECT imaging were 0.97 (95% CI, 0.95-1.00; I2 = 0%) and 0.91 (95% CI, 0.87-0.94; I2 = 0%), respectively. CONCLUSIONS: SPECT exhibited superior diagnostic performance for PE. V/Q SPECT/CT was the most accurate modality.
引用
- Bang JI, Lee WW, Cho SG, et al. The Diagnostic Accuracy of SPECT Imaging in Patients With Suspected Pulmonary Embolism: Systematic Review and Network Meta-analysis. Clin Nucl Med. 2024. PMID: 38831512. doi:10.1097/RLU.0000000000005167
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。