基于可解释深度学习联合O-15 H2O灌注PET/CT与临床数据检测缺血
研究开发了一种可解释的深度学习分类器,利用O-15 H2O灌注PET/CT极坐标图及35项临床、CTA和PET变量,在138例受试者中以有创冠状动脉造影为参考识别血流限制性冠状动脉疾病。模型中位准确度0.8478、AUC 0.8481,与临床判读性能相近且差异无统计学意义,并能以可解释方式突出重要数据发现。
要点
- 深度学习模型在138例中以有创冠状动脉造影为参考,中位准确度0.8478、AUC 0.8481。
- 模型中位敏感度0.8500、特异度0.8846、精确率0.8500、F1分数0.8293。
- 模型与临床判读性能相近,统计学检验无显著差异。
核心结论
- 联合深度学习模型是检测冠状动脉疾病的可行且有效方法,能以可解释方式个体化突出重要数据发现。
研究设计与样本
- 开发并评估了一种深度学习模型,在138例个体上测试,分类器结合图像与数据,考虑35项临床、CTA和PET变量,以有创冠状动脉造影数据为参考。
主要发现
- 深度学习模型中位准确度0.8478、AUC 0.8481、F1分数0.8293、敏感度0.8500、特异度0.8846、精确率0.8500。
- 模型改善真阳性与假阴性病例检出,在阈值至34%范围内净获益增加,Cohen kappa与临床判读相当,达到与临床判读相似的性能。
- 统计学检验显示深度学习模型与临床判读之间无显著差异。
关键数值与推荐
- 以有创冠状动脉造影为参考标准,评估指标包括准确度、ROC曲线下面积、F1分数、敏感度、特异度、精确率、净获益和Cohen kappa。
- 统计检验采用McNemar检验。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We developed an explainable deep-learning (DL)-based classifier to identify flow-limiting coronary artery disease (CAD) by O-15 H2O perfusion positron emission tomography computed tomography (PET/CT) and coronary CT angiography (CTA) imaging. The classifier uses polar map images with numerical data and visualizes data findings. METHODS: A DLmodel was implemented and evaluated on 138 individuals, consisting of a combined image-and data-based classifier considering 35 clinical, CTA, and PET variables. Data from invasive coronary angiography were used as reference. Performance was evaluated with clinical classification using accuracy (ACC), area under the receiver operating characteristic curve (AUC), F1 score (F1S), sensitivity (SEN), specificity (SPE), precision (PRE), net benefit, and Cohen's Kappa. Statistical testing was conducted using McNemar's test. RESULTS: The DL model had a median ACC = 0.8478, AUC = 0.8481, F1S = 0.8293, SEN = 0.8500, SPE = 0.8846, and PRE = 0.8500. Improved detection of true-positive and false-negative cases, increased net benefit in thresholds up to 34%, and comparable Cohen's kappa was seen, reaching similar performance to clinical reading. Statistical testing revealed no significant differences between DL model and clinical reading. CONCLUSIONS: The combined DL model is a feasible and an effective method in detection of CAD, allowing to highlight important data findings individually in interpretable manner.
引用
- Teuho J, Schultz J, Klén R, et al. Explainable deep-learning-based ischemia detection using hybrid O-15 H2O perfusion positron emission tomography and computed tomography imaging with clinical data. J Nucl Cardiol. 2024. PMID: 38852900. doi:10.1016/j.nuclcard.2024.101889
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。