新诊断或复发前列腺癌患者中18F-氟妥昔司他图像判读的阅片者间与阅片者内可重复性:两项3期前瞻性多中心研究数据

Interreader and Intrareader Reproducibility of 18F-Flotufolastat Image Interpretation in Patients with Newly Diagnosed or Recurrent Prostate Cancer: Data from Two Phase 3 Prospective Multicenter Studies.
PubMed 文献 · J Nucl Med · 2024-08-01

基于两项3期前瞻性多中心研究的掩蔽图像评估,评估新诊断(n=352)或复发(n=389)前列腺癌患者18F-氟妥昔司他PET/CT的阅片者间与阅片者内可重复性。3名掩蔽阅片者判读,配对阅片者间一致率新诊断组≥95%、复发组≥75%,Fleiss κ分别为0.50和0.41,阅片者内一致率两组均≥86%。结论认为该图像可可靠判读,具有高度阅片者间和阅片者内一致性。

要点

  • 新诊断患者配对阅片者间一致率≥95%,复发患者≥75%。
  • Fleiss κ在新诊断患者为0.50,复发患者为0.41。
  • 两组阅片者内一致率均≥86%。

核心结论

  • 18F-氟妥昔司他PET/CT图像可可靠判读,具有高度阅片者间和阅片者内一致性。

研究设计与样本

  • 两项3期前瞻性多中心研究,对新诊断(n=352)或复发(n=389)前列腺癌患者的18F-氟妥昔司他PET/CT图像进行掩蔽评估,由3名掩蔽阅片者判读。

主要发现

  • 配对阅片者间一致率在新诊断患者为95%或更好,在复发患者为75%或更好。
  • Cohen κ从不可估计至0.55,Fleiss κ在新诊断患者为0.50、复发患者为0.41。
  • 一致率在新诊断患者前列腺部位最高(≥95%),在复发患者盆腔淋巴结最高(≥87%)。
  • 阅片者内一致率(首次与重复判读,20%图像,≥4周后)在两组均≥86%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Interreader and intrareader reproducibility of 18F-flotufolastat PET/CT scans in newly diagnosed and recurrent prostate cancer patients was assessed from masked image evaluations from two phase 3 studies. Methods: 18F-flotufolastat PET/CT images of newly diagnosed (n = 352) or recurrent (n = 389) patients were evaluated by 3 masked readers. Cohen κ was used to assess pairwise patient- and region-level interreader agreement. Agreement among all readers was assessed using Fleiss κ. Intrareader agreement between the first and repeat read (20% of images, ≥4 wk later) was assessed using Cohen κ. Results: Pairwise interreader agreement was 95% or better (newly diagnosed) and 75% or better (recurrent). The κ coefficients were impacted by the high-agreement-low-κ paradox: Cohen κ ranged from not estimable to 0.55, whereas Fleiss κ was 0.50 (newly diagnosed) and 0.41 (recurrent). Agreement was highest in the prostate of newly diagnosed patients (≥95%) and in the pelvic lymph nodes in recurrent patients (≥87%). Intrareader agreement was 86% or better across both populations. Conclusion: 18F-flotufolastat PET/CT images can be reliably interpreted, with a high degree of inter- and intrareader agreement.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Kuo PH, Esposito G, Ulaner GA, et al. Interreader and Intrareader Reproducibility of 18F-Flotufolastat Image Interpretation in Patients with Newly Diagnosed or Recurrent Prostate Cancer: Data from Two Phase 3 Prospective Multicenter Studies. J Nucl Med. 2024. PMID: 38871390. doi:10.2967/jnumed.123.267306