联合门控SPECT与心电向量图指导左心室导线定位以改善心脏再同步治疗反应的新方法:一项概念验证研究
这项概念验证研究纳入76例患者,用SPECT心肌灌注显像相位分析确定最晚机械收缩(LMC)节段,用心电向量图检测最晚电激动(LEA)位点,整合机械与电不同步推荐左心室导线放置位置。推荐组54例中74.1%对CRT有反应,非推荐组22例中36.4%有反应(P = .002)。多因素分析显示推荐节段起搏与反应独立相关(OR 7.33,95%CI 1.53-35.14,P = .013),Kaplan-Meier曲线显示推荐位置起搏长期预后更好。
要点
- 推荐组CRT反应率74.1%,非推荐组36.4%,差异有统计学意义(P = .002)。
- 推荐节段起搏与CRT反应独立相关,多因素OR 7.33(95%CI 1.53-35.14,P = .013)。
- Kaplan-Meier曲线显示推荐左心室导线位置起搏长期预后更好。
核心结论
- 整合机械与电不同步推荐节段起搏与改善的CRT反应及更好长期预后显著相关。
研究设计与样本
- 概念验证研究,队列共76例患者,按左心室导线是否位于推荐位点分为推荐组54例(71.1%)与非推荐组22例(28.9%)。
- LMC节段由SPECT心肌灌注显像相位分析确定,LEA位点由心电向量图检测。
- 推荐左心室导线放置节段依次为:与LEA位点重叠的LMC存活节段;邻近LEA位点的LMC存活节段;若以上均不符合则推荐左心室侧壁。
- 反应定义为CRT后6个月左心室收缩末期容积(LVESV)降低≥15%。
主要发现
- 推荐组74.1%的患者对CRT有反应,非推荐组36.4%为反应者(P = .002)。
- 单因素分析显示推荐节段起搏与反应增加独立相关(OR 5.00,95%CI 1.73-14.44,P = .003)。
- 多因素分析显示推荐节段起搏与反应增加独立相关(OR 7.33,95%CI 1.53-35.14,P = .013)。
- Kaplan-Meier曲线显示推荐左心室导线位置起搏长期预后更好。
关键数值与推荐
- CRT反应定义为CRT后6个月LVESV降低≥15%。
- 推荐节段优先顺序:与LEA重叠的LMC存活节段、邻近LEA的LMC存活节段、否则左心室侧壁。
临床怎么用
- 作者认为整合机械与电不同步推荐节段起搏与改善的CRT反应及更好长期预后显著相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The segment of the latest mechanical contraction (LMC) does not always overlap with the site of the latest electrical activation (LEA). By integrating both mechanical and electrical dyssynchrony, this proof-of-concept study aimed to propose a new method for recommending left ventricular (LV) lead placements, with the goal of enhancing response to cardiac resynchronization therapy (CRT). METHODS: The LMC segment was determined by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) phase analysis. The LEA site was detected by vectorcardiogram. The recommended segments for LV lead placement were as follows: (1) the LMC viable segments that overlapped with the LEA site; (2) the LMC viable segments adjacent to the LEA site; (3) If no segment met either of the above, the LV lateral wall was recommended. The response was defined as ≥15% reduction in left ventricular end-systolic volume (LVESV) 6-months after CRT. Patients with LV lead located in the recommended site were assigned to the recommended group, and those located in the non-recommended site were assigned to the non-recommended group. RESULTS: The cohort comprised of 76 patients, including 54 (71.1%) in the recommended group and 22 (28.9%) in the non-recommended group. Among the recommended group, 74.1% of the patients responded to CRT, while 36.4% in the non-recommended group were responders (P = .002). Compared to pacing at the non-recommended segments, pacing at the recommended segments showed an independent association with an increased response by univariate and multivariable analysis (odds ratio 5.00, 95% confidence interval 1.73-14.44, P = .003; odds ratio 7.33, 95% confidence interval 1.53-35.14, P = .013). Kaplan-Meier curves showed that pacing at the recommended LV lead position demonstrated a better long-term prognosis. CONCLUSION: Our findings indicate that pacing at the recommended segments, by integrating of mechanical and electrical dyssynchrony, is significantly associated with an improved CRT response and better long-term prognosis.
引用
- Si H, He Z, Malhotra S, et al. A novel method combining gated SPECT and vectorcardiography to guide left ventricular lead placement to improve response to cardiac resynchronization therapy: A proof of concept study. J Nucl Cardiol. 2024. PMID: 38697386. doi:10.1016/j.nuclcard.2024.101867
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。