[68Ga]Ga-FAPI-46 PET/CT用于阴茎癌——一项可行性研究
该单中心先导研究纳入11例组织病理学证实的阴茎癌患者,术前接受[68Ga]Ga-FAPI-46 PET/CT,并与术后组织病理学对比。分析8个原发肿瘤部位和4个淋巴结区域,原发灶SUVmax为16.2(9.1-25.8),病理证实的淋巴结区域SUVmax为17.9(16.4-23.5)。作者认为在该首个先导队列中无假阳性FAPI摄取,可能有助于检测隐匿性淋巴结转移,并可能据此在手术中省略术前无FAPI摄取增高的淋巴结区域。
要点
- 阴茎癌原发灶FAPI摄取增高,SUVmax为16.2(9.1-25.8)。
- 病理证实的淋巴结区域FAPI摄取高度增高,SUVmax为17.9(16.4-23.5)。
- 该先导队列中无假阳性FAPI摄取,作者认为可能有助于检测隐匿性淋巴结转移。
核心结论
- 在该首个先导队列中,无假阳性FAPI摄取,作者认为[68Ga]Ga-FAPI-46 PET/CT可能有助于检测隐匿性淋巴结转移,并可能据此在手术中省略术前无FAPI摄取增高的淋巴结区域。
研究设计与样本
- 该研究为单中心先导研究,纳入计划接受手术治疗的阴茎癌患者,术前行[68Ga]Ga-FAPI-46 PET/CT,并将术后组织病理学与PET/CT结果进行对比。
- 2022年1月至2022年6月共11例组织病理学证实的阴茎癌患者接受手术并在治疗前接受[68Ga]Ga-FAPI-46 PET/CT,分析8个原发肿瘤部位和4个淋巴结区域。
主要发现
- 原发肿瘤部位FAPI摄取增高,SUVmax为16.2(9.1-25.8)。
- 组织病理学证实的淋巴结区域在[68Ga]Ga-FAPI-46 PET/CT上显示FAPI摄取高度增高,SUVmax为17.9(16.4-23.5)。
- 该先导队列中无假阳性FAPI摄取。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文称该研究为单中心先导研究(single-center pilot study),共纳入11例患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Penile cancer is a rare entity and has a good prognosis in localized stage. Delayed surgical treatment of lymphatic disease is associated with poor overall survival but conventional imaging cannot detect occult lymph node metastasis sufficiently. Imaging cancer related fibroblasts has shown promising results as non-invasive staging tool in various tumor entities but has not yet been evaluated in penile cancer. METHODS: In this single-center pilot study, patients planned for surgical treatment for penile cancer underwent preoperatively [68Ga]Ga-FAPI-46 PET/CT. Post-operative histopathology was compared to [68Ga]Ga-FAPI-46 PET/CT results. RESULTS: From January 2022 to June 2022, a total number 11 patients with histopathologically proven penile cancer underwent surgery and received [68Ga]Ga-FAPI-46 PET/CT prior therapy. 8 primary tumor sites and 4 lymph node regions were analyzed. FAPI uptake was increased on primary tumor site (SUVmax 16.2 (9.1 - 25.8)). Histopathological proven lymph node regions showed highly increased FAPI uptakes (SUVmax 17.9 (16.4 - 23.5) on [68Ga]Ga-FAPI-46 PET/CT. CONCLUSION: In this first pilot cohort, there were no false-positive FAPI uptake which might allow the detection of occult lymph node metastasis by [68Ga]Ga-FAPI-46 PET/CT and might consequently lead to omitting lymph node regions during surgery that had no increased FAPI uptake pre-operatively.
引用
- Eismann L, Ledderose ST, Enzinger B, et al. [68Ga]Ga-FAPI-46 PET/CT for penile cancer - a feasibility study. Eur J Nucl Med Mol Imaging. 2024. PMID: 38761187. doi:10.1007/s00259-024-06763-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。