文献速递核素与放射性配体治疗放射性药物与辐射防护

基于深度学习的部分容积校正方法用于定量177Lu SPECT/CT成像

A Deep-Learning-Based Partial-Volume Correction Method for Quantitative 177Lu SPECT/CT Imaging.
PubMed 文献 · J Nucl Med · 2024-06-03

本研究提出DL-PVC方法,利用深度学习对177Lu SPECT/CT进行部分容积校正,训练基于10000个随机活度分布置于扩展心脏躯干体模并经SIMIND蒙特卡罗模拟生成SPECT图像。模拟分析显示DL-PVC在结构相似性指数、归一化均方根误差和体积活度准确度上优于无PVC和迭代Yang PVC,并在3D打印体模测量中验证了活度恢复与迭代Yang相似且无需分割。

要点

  • DL-PVC基于深度学习实现177Lu SPECT/CT部分容积校正,训练使用10000个随机活度分布体模与SIMIND模拟图像。
  • 模拟分析中DL-PVC的结构相似性指数/归一化均方根误差/体积活度准确度为0.95/7.8%/35.8%,优于无PVC的0.89/10.4%/12.1%和迭代Yang PVC的0.94/8.6%/15.1%。
  • 在3D打印体模的177Lu SPECT/CT测量中,DL-PVC活度恢复与迭代Yang方法相似且无需分割,并能在体素水平校正Gibbs振铃等其他图像伪影。

核心结论

  • 本研究展示了DL-PVC对定量177Lu SPECT/CT的附加价值,分析验证了DL-PVC的功能并为未来在临床图像数据上的部署铺平道路。

研究设计与样本

  • 方法学研究:使用10000个随机活度分布置于扩展心脏躯干体模的数据集进行训练,通过SIMIND蒙特卡罗模拟程序生成真实SPECT采集。
  • 分别使用CASToR和STIR重建软件进行无分辨率建模和有分辨率建模的SPECT重建,以地面真值活度分布与模拟SPECT图像配对训练多种U-Net。
  • 基于结构相似性指数、归一化均方根误差及新指标体积活度准确度进行定量分析,确定归一化、输入尺寸和网络架构的最优参数。
  • 在3D打印的不同几何体模的177Lu SPECT/CT测量中验证DL-PVC。

主要发现

  • 模拟分析显示DL-PVC的结构相似性指数/归一化均方根误差/体积活度准确度为0.95/7.8%/35.8%,优于无PVC的0.89/10.4%/12.1%和迭代Yang PVC的0.94/8.6%/15.1%。
  • 在3D打印体模的177Lu SPECT/CT测量中,DL-PVC显示的活度恢复与迭代Yang方法相似,且无需分割。
  • DL-PVC能够校正Gibbs振铃等其他图像伪影,在体素水平明显更优。

关键数值与推荐

  • DL-PVC的模拟分析性能:结构相似性指数0.95、归一化均方根误差7.8%、体积活度准确度35.8%。
  • 无PVC的模拟分析性能:结构相似性指数0.89、归一化均方根误差10.4%、体积活度准确度12.1%。
  • 迭代Yang PVC的模拟分析性能:结构相似性指数0.94、归一化均方根误差8.6%、体积活度准确度15.1%。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

With the development of new radiopharmaceutical therapies, quantitative SPECT/CT has progressively emerged as a crucial tool for dosimetry. One major obstacle of SPECT is its poor resolution, which results in blurring of the activity distribution. Especially for small objects, this so-called partial-volume effect limits the accuracy of activity quantification. Numerous methods for partial-volume correction (PVC) have been proposed, but most methods have the disadvantage of assuming a spatially invariant resolution of the imaging system, which does not hold for SPECT. Furthermore, most methods require a segmentation based on anatomic information. Methods: We introduce DL-PVC, a methodology for PVC of 177Lu SPECT/CT imaging using deep learning (DL). Training was based on a dataset of 10,000 random activity distributions placed in extended cardiac-torso body phantoms. Realistic SPECT acquisitions were created using the SIMIND Monte Carlo simulation program. SPECT reconstructions without and with resolution modeling were performed using the CASToR and STIR reconstruction software, respectively. The pairs of ground-truth activity distributions and simulated SPECT images were used for training various U-Nets. Quantitative analysis of the performance of these U-Nets was based on metrics such as the structural similarity index measure or normalized root-mean-square error, but also on volume activity accuracy, a new metric that describes the fraction of voxels in which the determined activity concentration deviates from the true activity concentration by less than a certain margin. On the basis of this analysis, the optimal parameters for normalization, input size, and network architecture were identified. Results: Our simulation-based analysis revealed that DL-PVC (0.95/7.8%/35.8% for structural similarity index measure/normalized root-mean-square error/volume activity accuracy) outperforms SPECT without PVC (0.89/10.4%/12.1%) and after iterative Yang PVC (0.94/8.6%/15.1%). Additionally, we validated DL-PVC on 177Lu SPECT/CT measurements of 3-dimensionally printed phantoms of different geometries. Although DL-PVC showed activity recovery similar to that of the iterative Yang method, no segmentation was required. In addition, DL-PVC was able to correct other image artifacts such as Gibbs ringing, making it clearly superior at the voxel level. Conclusion: In this work, we demonstrate the added value of DL-PVC for quantitative 177Lu SPECT/CT. Our analysis validates the functionality of DL-PVC and paves the way for future deployment on clinical image data.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Leube J, Gustafsson J, Lassmann M, et al. A Deep-Learning-Based Partial-Volume Correction Method for Quantitative 177Lu SPECT/CT Imaging. J Nucl Med. 2024. PMID: 38637141. doi:10.2967/jnumed.123.266889

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。