胸主动脉夹层移植术后炎症和/或感染所致18F-氟脱氧葡萄糖在正电子发射断层显像/计算机断层显像中的摄取模式
回顾性纳入60例胸主动脉移植术后患者共187次PET/CT,量化移植血管FDG摄取。感染移植血管SUVratio高于非感染(2.19 vs 1.63,P<0.001),摄取随时间缓慢下降但斜率无差异。非感染移植血管吻合口摄取更常见(66% vs 21%,OR 11.34),该效应在使用BioGlue®后减弱。
要点
- 感染移植血管FDG摄取高于非感染移植血管(SUVratio 2.19 vs 1.63,P<0.001)。
- 非感染移植血管吻合口FDG摄取更常见(66% vs 21%,OR 11.34,95%CI 3.61-35.66)。
- 移植血管涂层与FDG摄取无关联,BioGlue®可能影响吻合口摄取。
核心结论
- 胸主动脉移植术后PET/CT中,感染移植血管FDG摄取高于非感染移植血管。
- 非感染移植血管中局灶性摄取也常见,多与吻合口相关,与移植血管涂层无关,可能受BioGlue®使用影响。
研究设计与样本
- 回顾性纳入610例连续胸主动脉移植手术患者中的60例,共187次PET/CT。
- 采用最大标准化摄取值(SUVmax)及与肝脏背景比值(SUVratio)量化移植血管FDG摄取。
- 应用随机斜率与截距混合线性回归模型分析SUVratio随时间变化,广义估计方程分析吻合口摄取关联。
主要发现
- FDG摄取多为局灶性(90%)。
- 感染移植血管平均SUVratio 2.19(95%CI 2.05-2.32)vs 非感染移植血管1.63(95%CI 1.46-1.79),P<0.001。
- SUVratio随术后时间缓慢下降(每年-0.048;95%CI -0.15-0.051,P=0.34),感染与非感染移植血管斜率无差异(P=0.52)。
- SUVratio与BioGlue®使用无交互证据(截距P=0.73,斜率P=0.71),与移植血管涂层(明胶和胶原)也无交互(所有P>0.7)。
- 吻合口FDG摄取在非感染移植血管中更常见(66% vs 21%,OR 11.34;95%CI 3.61-35.66,P<0.001),使用BioGlue®后该效应减弱(OR 5.05;95%CI 0.45-56.9,P=0.19)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To identify 18F-fluorodeoxyglucose (FDG) uptake patterns in positron emission tomography/computed tomography (PET/CT) caused by infection, inflammation, surgical material, and/or graft coating. METHODS AND RESULTS: Of 610 consecutive patients with thoracic aortic graft surgery, 60 patients with 187 PET/CT were retrospectively included. We quantified FDG uptake in all grafts using maximum standardized uptake value (SUVmax) alone and in relation to liver background (SUVratio) and determined the uptake pattern. Mixed linear regression models with random slope and intercept were applied for the analysis of SUVratio over time and generalized estimating equations to analyze the associations with anastomosis uptake. FDG uptake was frequently focal (90%), higher in infected than in noninfected grafts (mean SUVratio 2.19; 95% CI 2.05-2.32 vs. 1.63; 1.46-1.79, P < 0.001), and decreasing slowly over time (SUVratio per year since surgery -0.048; 95% CI -0.15- 0.051, P = 0.34), without a difference in slope between infected and noninfected grafts (P = 0.52). There was no evidence of an interaction between SUVratio and use of BioGlue® surgical adhesive (intercept P = 0.73, slope P = 0.71), or graft coating (gelatin and collagen, all P > 0.7). FDG uptake at the anastomosis was more frequent in noninfected grafts than in infected grafts (66% vs. 21%, odds ratio (OR) 11.34; 95% CI 3.61-35.66, P < 0.001). This effect was attenuated by the use of BioGlue® (OR 5.05; 95% CI 0.45-56.9, P = 0.19). CONCLUSIONS: FDG uptake in PET/CT after thoracic aortic graft surgery is higher in infected grafts than in noninfected grafts. In noninfected grafts, focal uptake is also frequent, mostly anastomosis-associated, not associated with graft coating, and possibly affected by the use of BioGlue®.
引用
- Hasse B, Ledergerber B, Van Hemelrijck M, et al. 18F-fluorodeoxyglucose uptake patterns in positron emission tomography/computed tomography caused by inflammation and/or infection after graft surgery for thoracic aortic dissection. J Nucl Cardiol. 2024. PMID: 38679286. doi:10.1016/j.nuclcard.2024.101865
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。