18F-FDG动力学映射与患者特异性Bootstrap不确定性评估:长轴视野PET/CT扫描仪数据示例
本研究在24例癌症患者的长轴视野PET/CT扫描仪动态18F-FDG数据上,采用非参数残差映射(NPRM)技术映射动力学参数,并用基于图像的Bootstrap方法评估不确定性。NPRM生成的动力学图质量良好,与血管和代谢模式对齐;NPRM对VOI时间过程数据的拟合优于标准2室模型,拟合改善具有高度统计学意义。结论认为NPRM联合图像域Bootstrap在大体量全身动态18F-FDG数据集上可行,Bootstrap信息可支持PET生物标志物更精细的临床应用。
要点
- 在24例癌症患者长轴视野PET/CT动态18F-FDG数据中,NPRM生成的动力学图质量良好。
- NPRM对VOI时间过程数据的拟合优于2室模型,拟合改善具有高度统计学意义。
- NPRM与2室模型评估的18F-FDG通量值总体相似,但血管血与分布容积估计存在显著偏差。
核心结论
- NPRM动力学联合图像域Bootstrap在大体量全身动态18F-FDG数据集上是可行的。
- Bootstrap提供的信息可支持PET生物标志物在个体患者临床决策中更精细的应用。
研究设计与样本
- 研究纳入24例癌症患者,在长轴视野PET/CT扫描仪上采集动态18F-FDG数据。
- 采用非参数残差映射(NPRM)技术映射动力学参数,并用基于图像的Bootstrap方法评估不确定性。
- 对体素、最大强度投影及对应关键器官和病灶的容积感兴趣区(VOI)报告动力学与Bootstrap导出的不确定性。
- 仔细比较了NPRM与VOI动力学的标准2室(2C)模型。
主要发现
- NPRM生成的动力学图质量良好,与血管和代谢18F-FDG模式对齐良好,在所考虑的VOI范围内合理。
- 在单个3.2 GHz处理器上,Bootstrap模型设定耗时140分钟,单个Bootstrap重复各需80分钟。
- NPRM比2C模型构建更准确地表示VOI时间过程数据,尤其在早期时间过程,拟合改善具有高度统计学意义。
- NPRM与2C模型评估的18F-FDG通量值总体相似,但血管血与分布容积估计之间发现显著偏差。
- Bootstrap能够评估映射动力学的相当复杂的汇总指标,并以动力学及其不确定性的最大强度图为例说明。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The purpose of this study was to examine a nonparametric approach to mapping kinetic parameters and their uncertainties with data from the emerging generation of dynamic whole-body PET/CT scanners. Methods: Dynamic PET 18F-FDG data from a set of 24 cancer patients studied on a long-axial-field-of-view PET/CT scanner were considered. Kinetics were mapped using a nonparametric residue mapping (NPRM) technique. Uncertainties were evaluated using an image-based bootstrapping methodology. Kinetics and bootstrap-derived uncertainties are reported for voxels, maximum-intensity projections, and volumes of interest (VOIs) corresponding to several key organs and lesions. Comparisons between NPRM and standard 2-compartment (2C) modeling of VOI kinetics are carefully examined. Results: NPRM-generated kinetic maps were of good quality and well aligned with vascular and metabolic 18F-FDG patterns, reasonable for the range of VOIs considered. On a single 3.2-GHz processor, the specification of the bootstrapping model took 140 min; individual bootstrap replicates required 80 min each. VOI time-course data were much more accurately represented, particularly in the early time course, by NPRM than by 2C modeling constructs, and improvements in fit were statistically highly significant. Although 18F-FDG flux values evaluated by NPRM and 2C modeling were generally similar, significant deviations between vascular blood and distribution volume estimates were found. The bootstrap enables the assessment of quite complex summaries of mapped kinetics. This is illustrated with maximum-intensity maps of kinetics and their uncertainties. Conclusion: NPRM kinetics combined with image-domain bootstrapping is practical with large whole-body dynamic 18F-FDG datasets. The information provided by bootstrapping could support more sophisticated uses of PET biomarkers used in clinical decision-making for the individual patient.
引用
- Wu Q, Gu F, O'Suilleabhain LD, et al. Mapping 18F-FDG Kinetics Together with Patient-Specific Bootstrap Assessment of Uncertainties: An Illustration with Data from a PET/CT Scanner with a Long Axial Field of View. J Nucl Med. 2024. PMID: 38604759. doi:10.2967/jnumed.123.266686
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。