结合MRI减少18F-DCFPyL PSMA PET/CT中前列腺尿道尿液滞留所致假阳性
该回顾性研究纳入85例同时接受18F-DCFPyL PSMA PET/CT与前列腺MRI的患者,分析前列腺中线放射性活度与排尿后T2加权MRI上尿道高信号(提示尿液滞留)的相关性。结果显示,有中线活度组尿道高信号比例为71.4%(10/14),无中线活度组为29.6%(21/71),差异有统计学意义(P<0.01);有中线活度组尿道尺寸更大、前列腺体积更大、严重尿道弯曲发生率更高。作者结论认为,前列腺尿道内滞留尿液是PSMA PET的潜在混杂因素,联合T2W MRI可减少假阳性判读。
要点
- 前列腺中线18F-DCFPyL活度可能与前列腺尿道滞留尿液相关,而非前列腺内病灶。
- 有中线活度组排尿后T2W MRI尿道高信号比例为71.4%(10/14),无中线活度组为29.6%(21/71),P<0.01。
- 有中线活度组尿道尺寸更大、前列腺体积更大、严重尿道弯曲发生率更高。
核心结论
- 前列腺尿道内滞留尿液是PSMA PET扫描的潜在混杂因素。
- 将PET成像与T2W MRI结合可减少假阳性判读,尤其当PSMA PET/CT在局限性前列腺癌诊断中持续获得应用时。
研究设计与样本
- 回顾性分析2017年7月至2023年9月间同时接受18F-DCFPyL PSMA PET/CT和前列腺MRI的85例患者。
- 评估前列腺中线放射性活度与排尿后T2W MRI上滞留尿液(尿道高信号)的相关性。
- 采用Fisher精确检验和非配对t检验比较有、无中线放射性活度患者间的残余尿存在与前列腺尿道测量值。
- 探索前列腺体积和尿道弯曲等解剖因素对尿液滞留的影响。
主要发现
- PSMA PET上有中线活度者14例(病例组),无中线活度者71例(对照组)。
- 病例组71.4%(10/14)与对照组29.6%(21/71)的患者在T2W MRI上有尿道高信号(P<0.01)。
- 病例组平均尿道尺寸更大、前列腺体积更大、严重尿道弯曲发生率更高,与对照组相比差异有统计学意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Prostate-specific membrane antigen (PSMA)-targeting PET radiotracers reveal physiologic uptake in the urinary system, potentially misrepresenting activity in the prostatic urethra as an intraprostatic lesion. This study examined the correlation between midline 18 F-DCFPyL activity in the prostate and hyperintensity on T2-weighted (T2W) MRI as an indication of retained urine in the prostatic urethra. PATIENTS AND METHODS: Eighty-five patients who underwent both 18 F-DCFPyL PSMA PET/CT and prostate MRI between July 2017 and September 2023 were retrospectively analyzed for midline radiotracer activity and retained urine on postvoid T2W MRIs. Fisher's exact tests and unpaired t tests were used to compare residual urine presence and prostatic urethra measurements between patients with and without midline radiotracer activity. The influence of anatomical factors including prostate volume and urethral curvature on urinary stagnation was also explored. RESULTS: Midline activity on PSMA PET imaging was seen in 14 patients included in the case group, whereas the remaining 71 with no midline activity constituted the control group. A total of 71.4% (10/14) and 29.6% (21/71) of patients in the case and control groups had urethral hyperintensity on T2W MRI, respectively ( P < 0.01). Patients in the case group had significantly larger mean urethral dimensions, larger prostate volumes, and higher incidence of severe urethral curvature compared with the controls. CONCLUSIONS: Stagnated urine within the prostatic urethra is a potential confounding factor on PSMA PET scans. Integrating PET imaging with T2W MRI can mitigate false-positive calls, especially as PSMA PET/CT continues to gain traction in diagnosing localized prostate cancer.
引用
- Gelikman DG, Mena E, Lindenberg L, et al. Reducing False-Positives Due to Urinary Stagnation in the Prostatic Urethra on 18 F-DCFPyL PSMA PET/CT With MRI. Clin Nucl Med. 2024. PMID: 38651785. doi:10.1097/RLU.0000000000005220
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。