18F-FDG PET上的单片眼镜征提示对侧周围性面神经麻痹
该回顾性研究分析了85例单侧面神经麻痹患者的FDG PET/CT数据,其中周围性73例、中枢性12例,测量双侧眼轮匝肌FDG摄取。周围性面神经麻痹患者的眼轮匝肌SUVmax比值显著高于中枢性面神经麻痹及无面神经麻痹者,最佳截断值1.41对应特异度94.4%、敏感度44.1%。作者结论认为眼轮匝肌不对称摄取增高(单片眼镜征)提示对侧周围性面神经麻痹。
要点
- 周围性面神经麻痹患者眼轮匝肌SUVmax比值显著高于中枢性面神经麻痹及无面神经麻痹者。
- SUVmax比值最佳截断值1.41,识别对侧周围性面神经麻痹特异度94.4%、敏感度44.1%。
- 截断值1.91时特异度达100%,敏感度29.4%。
核心结论
- 眼轮匝肌不对称FDG摄取增高(单片眼镜征)提示对侧周围性面神经麻痹。
- 作者认为SUVmax比值近2倍增高是具有实用价值的截断值。
研究设计与样本
- 回顾性分析85例单侧面神经麻痹患者的FDG PET/CT数据,其中周围性面神经麻痹73例、中枢性面神经麻痹12例。
- 测量双侧眼轮匝肌的SUVmax、SUVmean及总病灶糖酵解,并与33例无面神经麻痹患者比较。
- 采用受试者工作特征曲线及约登指数确定对侧周围性面神经麻痹的最佳SUVmax比值截断值。
主要发现
- 眼轮匝肌SUVmax比值在周围性面神经麻痹组为1.70±0.94,中枢性面神经麻痹组为1.16±0.09,无面神经麻痹组为1.18±0.21,组间差异P<0.001。
- 眼轮匝肌SUVmax比值识别对侧周围性面神经麻痹的曲线下面积为0.719(95%CI 0.630-0.809)。
关键数值与推荐
- SUVmax比值最佳截断值1.41,识别对侧周围性面神经麻痹的特异度为94.4%、敏感度为44.1%。
- 截断值1.91时特异度达100%,敏感度29.4%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of our study was to retrospectively analyze FDG PET/CT data in patients with facial nerve palsy (FNP) for the presence of the monocle sign. PATIENTS AND METHODS: A total of 85 patients with unilateral FNP were included into our study, thereof 73 with peripheral FNP and 12 with central FNP. FDG uptake (SUV max , SUV mean , total lesion glycolysis) was measured in both orbicularis oculi muscles (OOMs). FDG uptake of paretic and nonparetic muscles was compared in patients with FNP (Wilcoxon test and Mann-Whitney U test) and was also compared with FDG uptake in 33 patients without FNP (Mann-Whitney U test). SUV max ratios of OOM were compared. A receiver operating characteristic curve and Youden Index were used to determine the optimal cutoff SUV max ratio for the prevalence of contralateral peripheral FNP. RESULTS: The SUV max ratio of OOM was significantly higher in patients with peripheral FNP compared with patients with central FNP and those without FNP (1.70 ± 0.94 vs 1.16 ± 0.09 vs 1.18 ± 0.21, respectively; P < 0.001). The SUV max ratio of OOM yielded an area under the curve (AUC) of 0.719 (95% confidence interval, 0.630-0.809), with an optimal cutoff of 1.41, yielding a specificity of 94.4% and a sensitivity of 44.1% for identifying contralateral peripheral FNP. One hundred percent specificity is achieved using a cutoff of 1.91 (sensitivity, 29.4%). CONCLUSIONS: Asymmetrically increased FDG uptake of the OOM (the "monocle sign") indicates contralateral peripheral FNP. A nearly 2-fold higher SUV max represents a practically useful cutoff.
引用
- Dana F, Maurer A, Muehlematter UJ, et al. The Monocle Sign on 18 F-FDG PET Indicates Contralateral Peripheral Facial Nerve Palsy. Clin Nucl Med. 2024. PMID: 38651767. doi:10.1097/RLU.0000000000005238
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。