文献速递心脏核医学

一站式连续快速成像协议在心脏专用碲锌镉SPECT上定量心肌血流量以检测限流性冠状动脉疾病的可行性

Feasibility of myocardial blood flow quantification to detect flow-limited coronary artery disease with a one-day rest/stress continuous rapid imaging protocol on cardiac-dedicated cadmium zinc telluride single photon emission computed tomography.
PubMed 文献 · J Nucl Cardiol · 2024-02-20

研究纳入120例临床特征与血管造影结果匹配的患者,比较间歇序贯成像(ISI)与连续快速成像(CRI)两种一日静息/负荷SPECT协议定量心肌血流(MBF)的效果。CRI协议将成像时间从157.6分钟缩短至25.5分钟,静息残留活性(RRA)略高(26.7%±3.6% vs 22.3%±4.9%);经残留活性校正(RAC)后,两种协议的负荷MBF和心肌血流储备(MFR)无显著差异,诊断灵敏度82.1%-92.3%、特异度81.2%-91.2%。结论认为CRI协议联合静息RAC可行,能保证MBF定量诊断性能并缩短检查时间、提升患者舒适度。

要点

  • CRI协议成像时间约25.5分钟,较ISI协议157.6分钟缩短约6.2倍。
  • CRI协议RRA为26.7%±3.6%,略高于ISI协议的22.3%±4.9%。
  • 经RAC后两协议负荷MBF与MFR无显著差异,诊断灵敏度82.1%-92.3%、特异度81.2%-91.2%。

核心结论

  • 一日静息/负荷SPECT采用CRI协议联合静息RAC可行,能在缩短检查时间的同时保证MBF定量的诊断性能。
  • 原文结论提出需进一步评估心脏外活性对局部MBF和灌注模式的影响。
  • 原文结论提出需在典型SPECT MPI转诊人群(包括已知或疑似冠状动脉微血管疾病患者)中进一步评估。

研究设计与样本

  • 纳入120例临床特征与血管造影结果匹配、完成一日静息/负荷SPECT成像的患者。
  • 患者分别采用ISI协议(两次动态扫描和两次心电门控扫描)或CRI协议(两次动态/心电门控扫描)。
  • MBF定量采用残留活性校正(RAC)校正负荷动态SPECT扫描中的静息残留活性(RRA),用于检测限流性冠状动脉疾病。

主要发现

  • CRI协议较ISI协议缩短约6.2倍(25.5分钟 vs 157.6分钟)。
  • CRI协议RRA为26.7%±3.6%,ISI协议为22.3%±4.9%。
  • 经RAC后,两协议负荷MBF分别为2.18±1.13 vs 2.05±1.10(P > 0.05)。
  • 经RAC后,两协议MFR分别为2.42±1.05 vs 2.48±1.11(P > 0.05)。
  • 两协议诊断灵敏度为82.1%-92.3%,特异度为81.2%-91.2%;心肌灌注和左心室功能总体无显著差异(所有P > 0.26)。

关键数值与推荐

  • CRI协议成像时间25.5分钟,ISI协议157.6分钟。
  • CRI协议RRA 26.7%±3.6%,ISI协议22.3%±4.9%。
  • 经RAC后负荷MBF:CRI协议2.18±1.13 vs ISI协议2.05±1.10(P > 0.05)。
  • 经RAC后MFR:CRI协议2.42±1.05 vs ISI协议2.48±1.11(P > 0.05)。
  • 诊断灵敏度82.1%-92.3%,特异度81.2%-91.2%;心肌灌注和左心室功能所有P > 0.26。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论提出需进一步评估心脏外活性对局部MBF和灌注模式的影响。
  • 原文结论提出需在典型SPECT MPI转诊人群(包括已知或疑似冠状动脉微血管疾病患者)中进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization. METHODS: One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease. RESULTS: The CRI protocol reduced about 6.2 times shorter than the ISI protocol (25.5 min vs 157.6 min), but slightly higher than the RRA (26.7% ± 3.6% vs 22.3% ± 4.9%). With RAC, both protocols demonstrated close stress MBF (2.18 ± 1.13 vs 2.05 ± 1.10, P > 0.05) and myocardial flow reserve (MFR) (2.42 ± 1.05 vs 2.48 ± 1.11, P > 0.05) to deliver comparable diagnostic performance (sensitivity = 82.1%-92.3%, specificity = 81.2%-91.2%). Myocardial perfusion and left ventricular function overall showed no significant difference (all P > 0.26). CONCLUSION: One-day rest/stress SPECT with the CRI protocol and rest RAC is feasible to warrant the diagnostic performance of MBF quantitation with a shortened examination time and enhanced patient comfort. Further evaluation on the impact of extracardiac activity to regional MBF and perfusion pattern is required. Additional evaluation is needed in a patient population that is typical of those referred for SPECT MPI, including those with known or suspected coronary microvascular disease.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Wang J, Chen Y, Chu H, et al. Feasibility of myocardial blood flow quantification to detect flow-limited coronary artery disease with a one-day rest/stress continuous rapid imaging protocol on cardiac-dedicated cadmium zinc telluride single photon emission computed tomography. J Nucl Cardiol. 2024. PMID: 38387736. doi:10.1016/j.nuclcard.2024.101825

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。