文献速递肿瘤 PET/CT

探究聚乙二醇化对药代动力学的影响:聚乙二醇尺寸对前列腺特异性膜抗原抑制剂的大小依赖性效应

Exploring the impact of PEGylation on pharmacokinetics: a size-dependent effect of polyethylene glycol on prostate-specific membrane antigen inhibitors.
PubMed 文献 · EJNMMI Res · 2024-02-07

本研究开发了两种68Ga标记的PSMA靶向放射性示踪剂[68Ga]Ga-PP4-WD和[68Ga]Ga-PP8-WD,两者聚乙二醇(PEG)尺寸不同。两者对PSMA亲和力高,IC50分别为8.06 ± 0.91 nM和6.13 ± 0.79 nM,PET显像可清晰显示LNCaP肿瘤,且均经肾脏快速清除,30分钟时肾摄取分别比[68Ga]Ga-Flu-1低十倍和五倍。体内外实验表明PEG尺寸显著影响肿瘤靶向和药代动力学特性。

要点

  • 两种68Ga标记PSMA抑制剂[68Ga]Ga-PP4-WD和[68Ga]Ga-PP8-WD对PSMA亲和力高,IC50分别为8.06 ± 0.91 nM和6.13 ± 0.79 nM。
  • 两种示踪剂在PET显像中清晰显示LNCaP肿瘤,肿瘤-背景对比度好,且被LNCaP细胞高效摄取和内化。
  • 30分钟时[68Ga]Ga-PP4-WD和[68Ga]Ga-PP8-WD肾摄取分别比[68Ga]Ga-Flu-1低十倍和五倍。

核心结论

  • 两种放射性示踪剂在显著降低肾摄取的同时维持了肿瘤吸收剂量。
  • 两种示踪剂体外结合和内化特性强,体内对PSMA显示高特异性和亲和力。
  • 体内外实验均表明PEG尺寸显著影响肿瘤靶向和药代动力学特性。

研究设计与样本

  • 本研究开发了两种68Ga标记的PSMA靶向放射性示踪剂[68Ga]Ga-PP4-WD和[68Ga]Ga-PP8-WD,二者PEG尺寸不同。
  • 研究进行了体外亲和力、细胞摄取和内化实验,以及体内PET显像和生物分布研究。

主要发现

  • [68Ga]Ga-PP4-WD和[68Ga]Ga-PP8-WD对PSMA的IC50分别为8.06 ± 0.91 nM和6.13 ± 0.79 nM。
  • 两种示踪剂在PET图像中清晰显示LNCaP肿瘤,肿瘤-背景对比度好。
  • 两种示踪剂被LNCaP细胞高效摄取和内化,且随时间增加。
  • 生物分布研究显示两种放射性配体在LNCaP肿瘤中具有显著且特异性的摄取。
  • 30分钟时[68Ga]Ga-PP4-WD和[68Ga]Ga-PP8-WD的肾摄取分别比[68Ga]Ga-Flu-1低十倍和五倍。

关键数值与推荐

  • [68Ga]Ga-PP4-WD对PSMA的IC50为8.06 ± 0.91 nM。
  • [68Ga]Ga-PP8-WD对PSMA的IC50为6.13 ± 0.79 nM。
  • 30分钟时[68Ga]Ga-PP4-WD肾摄取比[68Ga]Ga-Flu-1低十倍。
  • 30分钟时[68Ga]Ga-PP8-WD肾摄取比[68Ga]Ga-Flu-1低五倍。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prostate cancer is the second most frequent cancer and the fifth leading cause of cancer-related deaths in men. Prostate-specific membrane antigen (PSMA) as a target has gained increasing attention. This research aims to investigate and understand how altering size of PEG impacts the in vitro and in vivo behavior and performance of PSMA inhibitors, with a specific focus on their pharmacokinetic characteristics and targeting properties. RESULTS: Two 68Ga-labeled PSMA-targeted radiotracers were developed, namely [68Ga]Ga-PP4-WD and [68Ga]Ga-PP8-WD, with varying sizes of polyethylene glycol (PEG). [68Ga]Ga-PP4-WD and [68Ga]Ga-PP8-WD had excellent affinity for PSMA with IC50 being 8.06 ± 0.91, 6.13 ± 0.79 nM, respectively. Both tracers enabled clear visualization of LNCaP tumors in PET images with excellent tumor-to-background contrast. They also revealed highly efficient uptake and internalization into LNCaP cells, increasing over time. The biodistribution studies demonstrated that both radioligands exhibited significant and specific uptake into LNCaP tumors. Furthermore, they were rapidly cleared through the renal pathway, as evidenced by [68Ga]Ga-PP4-WD and [68Ga]Ga-PP8-WD showing a tenfold and a fivefold less in renal uptake, respectively, compared to [68Ga]Ga-Flu-1 in 30 min. Both in vitro and in vivo experiments demonstrated that PEG size significantly impacted tumor-targeting and pharmacokinetic properties. CONCLUSIONS: These radiotracers have demonstrated their effectiveness in significantly reducing kidney uptake while maintaining the absorbed dose in tumors. Both radiotracers exhibited strong binding and internalization characteristics in vitro, displayed high specificity and affinity for PSMA in vivo.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Liu Y, Xia L, Li H, et al. Exploring the impact of PEGylation on pharmacokinetics: a size-dependent effect of polyethylene glycol on prostate-specific membrane antigen inhibitors. EJNMMI Res. 2024. PMID: 38324095. doi:10.1186/s13550-024-01071-z