文献速递心脏核医学放射性药物与辐射防护

使用长轴视野PET/CT对[82Rb]Cl进行内照射剂量学研究

Internal dosimetry study of [82Rb]Cl using a long axial field-of-view PET/CT.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2024-02-26

本研究利用长轴视野(LAFOV)PET/CT对三名受试者(29、40、57岁)注射407.0至419.61 MBq的[82Rb]Cl后进行7分钟动态扫描,采用MIRD和体素剂量学两种方法测定靶器官吸收剂量。结果显示心脏壁、肾脏和肺的吸收剂量范围分别为1.84–2.78 μGy/MBq和1.57–3.92 μGy/MBq、2.76–5.73 μGy/MBq和3.22–5.37 μGy/MBq、0.94–1.88 μGy/MBq和0.98–1.92 μGy/MBq,全身有效剂量为0.50–0.76 μSv/MBq。研究提示[82Rb]Cl PET/CT相关的辐射剂量低于文献值。

要点

  • LAFOV PET/CT单床位动态采集可用于[82Rb]Cl的内照射剂量评估。
  • MIRD与体素剂量学法测得心脏壁吸收剂量分别为1.84–2.78与1.57–3.92 μGy/MBq。
  • 全身有效剂量为0.50–0.76 μSv/MBq,低于文献值。

核心结论

  • 本研究提示[82Rb]Cl PET/CT相关的辐射剂量可通过动态LAFOV PET评估,且低于文献值。

研究设计与样本

  • 研究纳入三名受试者(29、40和57岁),注射407.0至419.61 MBq的[82Rb]Cl后用LAFOV PET/CT进行7分钟动态扫描。
  • 采用MIRD和体素剂量学两种方法测定靶器官吸收剂量。

主要发现

  • MIRD法测得心脏壁吸收剂量为1.84至2.78 μGy/MBq,体素剂量学法为1.57至3.92 μGy/MBq。
  • MIRD法测得肾脏吸收剂量为2.76至5.73 μGy/MBq,体素剂量学法为3.22至5.37 μGy/MBq。
  • MIRD法测得肺吸收剂量为0.94至1.88 μGy/MBq,体素剂量学法为0.98至1.92 μGy/MBq。
  • 全身有效剂量介于0.50至0.76 μSv/MBq之间。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Long axial field-of-view (LAFOV) positron emission tomography (PET) systems allow to image all major organs with one bed position, which is particularly useful for acquiring whole-body dynamic data using short-lived radioisotopes like 82Rb. METHODS: We determined the absorbed dose in target organs of three subjects (29, 40, and 57 years old) using two different methods, i.e., MIRD and voxel dosimetry. The subjects were injected with 407.0 to 419.61 MBq of [82Rb]Cl and were scanned dynamically for 7 min with a LAFOV PET/CT scanner. RESULTS: Using the MIRD formalism and voxel dosimetry, the absorbed dose ranged from 1.84 to 2.78 μGy/MBq (1.57 to 3.92 μGy/MBq for voxel dosimetry) for the heart wall, 2.76 to 5.73 μGy/MBq (3.22 to 5.37 μGy/MBq for voxel dosimetry) for the kidneys, and 0.94 to 1.88 μGy/MBq (0.98 to 1.92 μGy/MBq for voxel dosimetry) for the lungs. The total body effective dose lied between 0.50 and 0.76 μSv/MBq. CONCLUSION: Our study suggests that the radiation dose associated with [82Rb]Cl PET/CT can be assessed by means of dynamic LAFOV PET and that it is lower compared to literature values.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Mercolli L, Bregenzer C, Diemling M, et al. Internal dosimetry study of [82Rb]Cl using a long axial field-of-view PET/CT. Eur J Nucl Med Mol Imaging. 2024. PMID: 38407598. doi:10.1007/s00259-024-06660-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。