铷-82与氧-15水心脏PET的定量与定性比较
在39例已知冠心病患者中,比较低摄取滞留型示踪剂铷-82与高摄取非滞留型示踪剂氧-15水的心脏PET心肌灌注显像判读及定量血流。两种示踪剂对区域可逆性缺血和全局疾病的判读一致性为74%,对区域不可逆性缺血为82%;氧-15水识别更多全局疾病病例(12例 vs 4例,p=0.03),可逆及不可逆缺血差异无统计学意义。
要点
- 铷-82与氧-15水心肌灌注显像对区域可逆性缺血和全局疾病的判读一致性为74%。
- 氧-15水识别全局疾病病例数多于铷-82(12例 vs 4例,p=0.03)。
- 两种示踪剂测定的心肌血流量相关性R²=0.78,一致性界限宽(-0.93至0.84 ml/g/min)。
核心结论
- 在已知冠心病患者中,铷-82与氧-15水心肌灌注显像的共识判读一致性良好,可逆与不可逆缺血的识别无显著差异,氧-15水对疑似全局疾病的阳性率更高。
研究设计与样本
- 39例因心绞痛转诊行铷-82心肌灌注显像的已知冠心病患者,接受两种示踪剂的静息和负荷显像,由经验丰富的判读者进行盲法共识判读,并比较区域和全局灌注定量指标。
主要发现
- 区域可逆性缺血和全局疾病的判读一致性为74%,区域不可逆性缺血为82%。
- 氧-15水识别全局疾病12例 vs 铷-82识别4例(p=0.03)。
- 可逆性缺血例数22 vs 16(p=0.11),不可逆性缺血例数8 vs 11(p=0.45),均无统计学显著差异。
- 两种示踪剂测定的心肌血流量相关性R²=0.78,一致性界限为-0.93至0.84 ml/g/min。
局限性
- 原文自述为有限样本量研究(limited size study)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Differences in tracer characteristics may influence the interpretation of positron emission tomography myocardial perfusion imaging (MPI). We compare the reading of MPIs with a low-extraction retention tracer (82Rb) and a high-extraction non-retention tracer (15O-water) in a selected cohort of patients with known coronary artery disease (CAD). METHODS: Thirty-nine patients with known CAD referred to 82Rb MPI due to angina underwent rest and stress imaging with both tracers and experienced MPI readers provided blinded consensus reads of all studies. In addition, a comparison of regional and global quantitative measures of perfusion was performed. RESULTS: The results showed 74 % agreement in the reading of 82Rb and 15O-water MPI for regional reversible ischemia and global disease, and 82 % agreement for regional irreversible ischemia. The 15O-water MPI identified more cases of global disease (n = 12 (15O-water) vs n = 4 (82Rb), p = 0.03), whereas differences in reversible ischemia (n = 22 vs n = 16, p = 0.11) and, irreversible ischemia (n = 8 vs n = 11, p = 0.45) were not significant. The correlation between myocardial blood flow measured using the two tracers was similar to previous studies (R2 = 0.78) with wide limits of agreement (-0.93 to 0.84 ml/g/min). CONCLUSIONS: Agreement between consensus readings of 82Rb and 15O-water MPI was good in patients with known CAD. In this limited size study, no significant differences in the identification of reversible and irreversible ischemia found, whereas 15O-water MPI had a higher positive rate for suspected global disease.
引用
- Hoff CM, Sørensen J, Kero T, et al. Quantitative and qualitative comparison of Rubidium-82 and Oxygen-15 water cardiac PET. J Nucl Cardiol. 2024. PMID: 38278706. doi:10.1016/j.nuclcard.2024.101796
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。