文献速递心脏核医学

负荷PET显像中心肌向下移位与死亡率呈负相关

Downward myocardial creep during stress PET imaging is inversely associated with mortality.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2024-01-23

研究纳入4276例连续接受瑞加诺生负荷-静息[82Rb]Cl PET心肌灌注显像的患者,用自动三维运动校正算法量化心肌移位。中位随访5年记录1007例全因死亡;向下移位越大,全因死亡率越低(校正HR 0.93,95%CI 0.91-0.95,p<0.001),且加入向下移位显著改善预测(AUC 0.790 vs 0.775,p<0.001)。

要点

  • 向下心肌移位中位4.2 mm,大于其他方向1.3-1.7 mm。
  • 向下移位越大全因死亡率越低,校正HR 0.93(95%CI 0.91-0.95,p<0.001)。
  • 加入向下移位后AUC由0.775升至0.790(p<0.001),其他方向无改善(p>0.5)。

核心结论

  • 瑞加诺生负荷动态PET心肌灌注显像中的向下心肌移位,在传统血流与灌注参数之外提供全因死亡预测的额外信息。
  • 该新型影像生物标志物可由负荷动态PET心肌灌注显像自动、快速量化。

研究设计与样本

  • 连续纳入接受瑞加诺生负荷-静息[82Rb]Cl PET心肌灌注显像的患者。
  • 采用新开发的三维运动校正算法量化心肌移位,即首次通过60秒负荷期各方向的最大运动。
  • 主要终点为全因死亡。
  • 共分析4276例患者,中位年龄71岁,男性占60%。

主要发现

  • 中位随访5年期间记录1007例全因死亡事件。
  • 自动运动校正处理时间每例患者<12秒。
  • 向上-向下(向下)方向心肌移位大于其他方向(中位4.2 mm vs 1.3-1.7 mm)。
  • 经年龄和性别校正的年死亡率随向下移位增大而降低,第一十分位(0 mm运动)与第十十分位(11 mm运动)之间比值为4.2倍(死亡率7.9%/年 vs 1.9%/年)。
  • 充分校正临床和影像参数后,向下移位与较低全因死亡相关(校正风险比0.93;95%CI 0.91-0.95;p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The myocardial creep is a phenomenon in which the heart moves from its original position during stress-dynamic PET myocardial perfusion imaging (MPI) that can confound myocardial blood flow measurements. Therefore, myocardial motion correction is important to obtain reliable myocardial flow quantification. However, the clinical importance of the magnitude of myocardial creep has not been explored. We aimed to explore the prognostic value of myocardial creep quantified by an automated motion correction algorithm beyond traditional PET-MPI imaging variables. METHODS: Consecutive patients undergoing regadenoson rest-stress [82Rb]Cl PET-MPI were included. A newly developed 3D motion correction algorithm quantified myocardial creep, the maximum motion at stress during the first pass (60 s), in each direction. All-cause mortality (ACM) served as the primary endpoint. RESULTS: A total of 4,276 patients (median age 71 years; 60% male) were analyzed, and 1,007 ACM events were documented during a 5-year median follow-up. Processing time for automatic motion correction was < 12 s per patient. Myocardial creep in the superior to inferior (downward) direction was greater than the other directions (median, 4.2 mm vs. 1.3-1.7 mm). Annual mortality rates adjusted for age and sex were reduced with a larger downward creep, with a 4.2-fold ratio between the first (0 mm motion) and 10th decile (11 mm motion) (mortality, 7.9% vs. 1.9%/year). Downward creep was associated with lower ACM after full adjustment for clinical and imaging parameters (adjusted hazard ratio, 0.93; 95%CI, 0.91-0.95; p < 0.001). Adding downward creep to the standard PET-MPI imaging model significantly improved ACM prediction (area under the receiver operating characteristics curve, 0.790 vs. 0.775; p < 0.001), but other directions did not (p > 0.5). CONCLUSIONS: Downward myocardial creep during regadenoson stress carries additional information for the prediction of ACM beyond conventional flow and perfusion PET-MPI. This novel imaging biomarker is quantified automatically and rapidly from stress dynamic PET-MPI.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Kuronuma K, Miller RJH, Wei CC, et al. Downward myocardial creep during stress PET imaging is inversely associated with mortality. Eur J Nucl Med Mol Imaging. 2024. PMID: 38253908. doi:10.1007/s00259-024-06611-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。