长轴视野PET/CT头颈部癌症短时长与长时长采集的临床可接受性:一项回顾性评估

The clinical acceptability of short versus long duration acquisitions for head and neck cancer using long-axial field-of-view PET/CT: a retrospective evaluation.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-12-14

该回顾性研究在长轴视野(LAFOV)2-[18F]FDG PET/CT系统上,比较头颈部癌症(HNC)患者4分钟(C40%)与10分钟(C100%)采集对FDG avid淋巴结(LN)转移的检测临床可接受性。共纳入64例HNC患者,两种采集间病灶检出率无显著差异(Pearson卡方检验,p=0.792),C100%的准确率改善达临界显著性(p=0.057),C100%的SUVmax(3.5)低于C40%(4.5)。

要点

  • C40%与C100%采集间淋巴结检出率无显著差异(Pearson卡方检验,p=0.792)。
  • C40%灵敏度83%、特异度44%、PPV 55%、NPV 76%、准确率36%;C100%分别为85%、56%、55%、85%、43%。
  • C100%准确率的改善达临界显著性(p=0.057)。

核心结论

  • 就淋巴结检测而言,C40%采集与C100%采集相比无显著差异。
  • C100%在病灶检测上有一定改善,准确率小幅提升达临界显著性,提示LAFOV带来的更高灵敏度可能转化为部分患者临床性能的改善。

研究设计与样本

  • 回顾性研究,按照预先设定的样本量计算纳入接受LAFOV PET/CT的HNC患者。
  • 共筛选1218份记录,最终纳入64例HNC患者,中位年龄65岁(IQR:59-73)。
  • 由两名委员会认证的核医学医师共识识别FDG avid且高度可能或可疑恶性的淋巴结,以组织学报告或确认性影像为参考标准。

主要发现

  • C40%共检出387个病灶(高度可能LN n=274,可疑n=113);C100%共检出439个病灶(高度可能LN n=291,占66%;可疑n=148,占34%)。
  • 两种采集间检出率无显著差异(Pearson卡方检验,p=0.792)。
  • C40%的灵敏度、特异度、PPV、NPV和准确率分别为83%、44%、55%、76%和36%;C100%分别为85%、56%、55%、85%和43%。
  • 准确率的改善达临界显著性(p=0.057)。
  • ROC分析中C100%的SUVmax(3.5)低于C40%(4.5)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the utility of long duration (10 min) acquisitions compared to standard 4 min scans in the evaluation of head and neck cancer (HNC) using a long-axial field-of-view (LAFOV) system in 2-[18F]FDG PET/CT. METHODS: HNC patients undergoing LAFOV PET/CT were included retrospectively according to a predefined sample size calculation. For each acquisition, FDG avid lymph nodes (LN) which were highly probable or equivocal for malignancy were identified by two board certified nuclear medicine physicians in consensus. The aim of this study was to establish the clinical acceptability of short-duration (4 min, C40%) acquisitions compared to full-count (10 min, C100%) in terms of the detection of LN metastases in HNC. Secondary endpoints were the positive predictive value for LN status (PPV) and comparison of SUVmax at C40% and C100%. Histology reports or confirmatory imaging were the reference standard. RESULTS: A total of 1218 records were screened and target recruitment was met with n = 64 HNC patients undergoing LAFOV. Median age was 65 years (IQR: 59-73). At C40%, a total of 387 lesions were detected (highly probable LN n = 274 and equivocal n = 113. The total number of lesions detected at C100% acquisition was 439, of them 291 (66%) highly probable LN and 148 (34%) equivocal. Detection rate between the two acquisitions did not demonstrate any significant differences (Pearson's Chi-Square test, p = 0.792). Sensitivity, specificity, PPV, NPV and accuracy for C40% were 83%, 44%, 55%, 76% and 36%, whilst for C100% were 85%, 56%, 55%, 85% and 43%, respectively. The improved accuracy reached borderline significance (p = 0.057). At the ROC analysis, lower SUVmax was identified for C100% (3.5) compared to C40% (4.5). CONCLUSION: In terms of LN detection, C40% acquisitions showed no significant difference compared to the C100% acquisitions. There was some improvement for lesions detection at C100%, with a small increment in accuracy reaching borderline significance, suggestive that the higher sensitivity afforded by LAFOV might translate to improved clinical performance in some patients.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Mei R, Pyka T, Sari H, et al. The clinical acceptability of short versus long duration acquisitions for head and neck cancer using long-axial field-of-view PET/CT: a retrospective evaluation. Eur J Nucl Med Mol Imaging. 2023. PMID: 38095670. doi:10.1007/s00259-023-06516-6