文献速递肿瘤 PET/CT核素与放射性配体治疗

基于卷积神经网络的前列腺癌全身[68Ga]Ga-PSMA PET图像全自动分割系统

A convolutional neural network-based system for fully automatic segmentation of whole-body [68Ga]Ga-PSMA PET images in prostate cancer.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-12-14

这项多中心研究纳入三个中心共412例前列腺癌患者的[68Ga]Ga-PSMA-11 PET/CT,基于nnU-Net框架构建全3D卷积神经网络,用于mPCa病灶的自动检测与分割;在患者级分类、病灶级检测和体素级分割三个层面评估,自动与手动分割的PSMA-TV和TL-PSMA在各中心均呈强相关。

要点

  • 患者级分类内部测试集准确率83%、灵敏度92%、PPV 77%、NPV 91%。
  • 病灶级检测所有测试集准确率87–94%、灵敏度88–95%、PPV 98–100%、F1评分93–97%。
  • 体素级分割所有测试集DSC 65–70%、PPV 72–79%、IoU 53–58%、灵敏度62–73%。

核心结论

  • 所提出的深度学习网络为前列腺癌患者[68Ga]Ga-PSMA PET恶性病灶的自动分割提供了有前景的解决方案。
  • 这些网络在全身分割中达到高水平的准确度,以体素级DSC和PPV衡量。
  • 所得分割结果可用于提取PET衍生定量生物标志物,并用于治疗反应评估和影像组学研究。

研究设计与样本

  • 多中心研究,纳入三个不同中心共412例有前列腺癌指征并接受[68Ga]Ga-PSMA-11 PET/CT的患者。
  • 中心1数据集的200例用于训练模型,采用基于自配置nnU-Net框架的全3D卷积神经网络(CNN)。
  • 中心1数据集的子集及中心2、中心3的病例用于模型测试。
  • 通过将全自动分割掩膜与对应内部和外部测试集的手动分割进行比较,在患者级扫描分类、病灶级检测和体素级分割三个层面评估分割流程性能。
  • 计算全身PSMA肿瘤体积(PSMA-TV)和总病灶PSMA摄取(TL-PSMA),比较自动与手动分割的PET衍生定量生物标志物。

主要发现

  • 患者级分类中,模型在内部测试集达到准确率83%、灵敏度92%、PPV 77%、NPV 91%。
  • 病灶级检测中,模型在所有测试集达到准确率87–94%、灵敏度88–95%、PPV 98–100%、F1评分93–97%。
  • 体素级分割中,自动方法在所有测试集达到DSC平均值65–70%、PPV 72–79%、IoU 53–58%、灵敏度62–73%。
  • 在体积参数评估中,所有中心的PSMA-TV和TL-PSMA手动与自动测量之间呈强相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was development and evaluation of a fully automated tool for the detection and segmentation of mPCa lesions in whole-body [68Ga]Ga-PSMA-11 PET scans by using a nnU-Net framework. METHODS: In this multicenter study, a cohort of 412 patients from three different center with all indication of PCa who underwent [68Ga]Ga-PSMA-11 PET/CT were enrolled. Two hundred cases of center 1 dataset were used for training the model. A fully 3D convolutional neural network (CNN) is proposed which is based on the self-configuring nnU-Net framework. A subset of center 1 dataset and cases of center 2 and center 3 were used for testing of model. The performance of the segmentation pipeline that was developed was evaluated by comparing the fully automatic segmentation mask with the manual segmentation of the corresponding internal and external test sets in three levels including patient-level scan classification, lesion-level detection, and voxel-level segmentation. In addition, for comparison of PET-derived quantitative biomarkers between automated and manual segmentation, whole-body PSMA tumor volume (PSMA-TV) and total lesions PSMA uptake (TL-PSMA) were calculated. RESULTS: In terms of patient-level classification, the model achieved an accuracy of 83%, sensitivity of 92%, PPV of 77%, and NPV of 91% for the internal testing set. For lesion-level detection, the model achieved an accuracy of 87-94%, sensitivity of 88-95%, PPV of 98-100%, and F1-score of 93-97% for all testing sets. For voxel-level segmentation, the automated method achieved average values of 65-70% for DSC, 72-79% for PPV, 53-58% for IoU, and 62-73% for sensitivity in all testing sets. In the evaluation of volumetric parameters, there was a strong correlation between the manual and automated measurements of PSMA-TV and TL-PSMA for all centers. CONCLUSIONS: The deep learning networks presented here offer promising solutions for automatically segmenting malignant lesions in prostate cancer patients using [68Ga]Ga-PSMA PET. These networks achieve a high level of accuracy in whole-body segmentation, as measured by the DSC and PPV at the voxel level. The resulting segmentations can be used for extraction of PET-derived quantitative biomarkers and utilized for treatment response assessment and radiomic studies.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Jafari E, Zarei A, Dadgar H, et al. A convolutional neural network-based system for fully automatic segmentation of whole-body [68Ga]Ga-PSMA PET images in prostate cancer. Eur J Nucl Med Mol Imaging. 2023. PMID: 38095671. doi:10.1007/s00259-023-06555-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。