文献速递神经核医学

新型[18F]FDG脑PET数据库的特征描述及其与第二数据库联合用于优化局灶性异常检测——以局灶性皮质发育不良为例

Characterisation of a novel [18F]FDG brain PET database and combination with a second database for optimising detection of focal abnormalities, using focal cortical dysplasia as an example.
PubMed 文献 · EJNMMI Res · 2023-11-15

本研究全面表征了一个未发表健康对照脑[18F]FDG PET数据库(马赛,n=60,21-78岁),并与公开数据库MRXFDG(n=37,23-65岁)比较;利用34例经组织学确诊的局灶性皮质发育不良(FCD)患者扫描评估异常检出率。单独比较马赛数据库检出率为50%,MRXFDG为53%,简单合并两数据库降至41%;经空间分辨率协调、全因子设计矩阵处理全局差异并排除60岁以上对照后,两数据库合并检出率最高达71%。

要点

  • 简单合并两个健康对照数据库会使FCD检出率从50%-53%降至41%。
  • 经空间分辨率协调、全因子设计矩阵及排除60岁以上对照后,合并数据库检出率最高达71%。
  • 三种扫描仪类型间检出率相似,MRI正常患者(n=10/11)检出率高。

核心结论

  • 全局与区域数据特征具有数据库特异性,但增加数据库规模有价值,数据库差异可通过协调方法克服,可能为传统统计或机器学习分析及临床实施提供参考。

研究设计与样本

  • 研究表征未发表健康对照脑[18F]FDG PET数据库(马赛,n=60,21-78岁),并与公开数据库MRXFDG(n=37,23-65岁)比较。
  • 使用34例经组织学确诊的局灶性皮质发育不良(FCD)患者扫描(13-48岁,来自三代扫描仪),通过标准软件SPM12估计异常检出率。

主要发现

  • 区域SUV模式相似,但全局值和分辨率如预期不同。
  • FCD检出率:与马赛数据库比较为50%,与MRXFDG比较为53%,简单合并两数据库为41%。
  • 经空间分辨率协调、使用全因子设计矩阵容纳全局差异并排除60岁以上对照后,两数据库合并检出率最高达71%。
  • 三种患者扫描仪类型间检出率相似,MRI正常患者(n=10/11)检出率高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Brain [18F]FDG PET is used clinically mainly in the presurgical evaluation for epilepsy surgery and in the differential diagnosis of neurodegenerative disorders. While scans are usually interpreted visually on an individual basis, comparison against normative cohorts allows statistical assessment of abnormalities and potentially higher sensitivity for detecting abnormalities. Little work has been done on out-of-sample databases (acquired differently to the patient data). Combination of different databases would potentially allow better power and discrimination. We fully characterised an unpublished healthy control brain [18F]FDG PET database (Marseille, n = 60, ages 21-78 years) and compared it to another publicly available database (MRXFDG, n = 37, ages 23-65 years). We measured and then harmonised spatial resolution and global values. A collection of patient scans (n = 34, 13-48 years) with histologically confirmed focal cortical dysplasias (FCDs) obtained on three generations of scanners was used to estimate abnormality detection rates using standard software (statistical parametric mapping, SPM12). RESULTS: Regional SUVs showed similar patterns, but global values and resolutions were different as expected. Detection rates for the FCDs were 50% for comparison with the Marseille database and 53% for MRXFDG. Simply combining both databases worsened the detection rate to 41%. After harmonisation of spatial resolution, using a full factorial design matrix to accommodate global differences, and leaving out controls older than 60 years, we achieved detection rates of up to 71% for both databases combined. Detection rates were similar across the three scanner types used for patients, and high for patients whose MRI had been normal (n = 10/11). CONCLUSIONS: As expected, global and regional data characteristics are database specific. However, our work shows the value of increasing database size and suggests ways in which database differences can be overcome. This may inform analysis via traditional statistics or machine learning, and clinical implementation.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Jin SO, Mérida I, Stavropoulos I, et al. Characterisation of a novel [18F]FDG brain PET database and combination with a second database for optimising detection of focal abnormalities, using focal cortical dysplasia as an example. EJNMMI Res. 2023. PMID: 37964137. doi:10.1186/s13550-023-01023-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。