68Ga-FAPI-04 PET/CT评估瘢痕疙瘩成纤维细胞活化的前瞻性初步研究
该前瞻性初步研究纳入25例瘢痕疙瘩患者行68Ga-FAPI-04 PET/CT,共检出123个病灶,多分布于前胸壁。不同部位摄取差异显著(P<0.0001),病灶内存在摄取异质性。SUVmax与温哥华瘢痕量表呈中度相关(r=0.565,P<0.0001),与FAPI表达呈中度相关(r=0.520,P=0.022)。结论认为该显像可反映瘢痕疙瘩组织中活化成纤维细胞的分布特征,可能为瘢痕疙瘩评估提供新方法。
要点
- 25例瘢痕疙瘩患者行68Ga-FAPI-04 PET/CT,共检出123个病灶,多分布于前胸壁。
- 不同部位68Ga-FAPI-04摄取差异显著(P<0.0001),部分大病灶边缘与中心摄取存在显著差异。
- SUVmax与温哥华瘢痕量表中度相关(r=0.565,P<0.0001),与FAPI表达中度相关(r=0.520,P=0.022)。
核心结论
- 68Ga-FAPI-04 PET/CT可反映瘢痕疙瘩组织中活化成纤维细胞的分布特征,可能为瘢痕疙瘩评估及后续成纤维细胞相关治疗提供新方法。
研究设计与样本
- 前瞻性初步研究,纳入25例瘢痕疙瘩患者行68Ga-FAPI-04 PET/CT,所有患者在1周内接受手术切除部分病灶。
- 测量SUVmean和SUVmax进行半定量分析,并与温哥华瘢痕量表、激光散斑对比成像、病理及免疫组化染色进行比较。
主要发现
- 25例患者共检出123个病灶,多数分布于前胸壁。
- 不同部位68Ga-FAPI-04摄取差异显著(P<0.0001)。
- 瘢痕疙瘩病灶内存在摄取异质性,部分大病灶边缘与中心之间差异显著。
- 68Ga-FAPI-04 SUVmax与温哥华瘢痕量表呈中度相关(r=0.565,P<0.0001),与激光散斑对比成像参数呈轻度相关。
- 68Ga-FAPI-04 SUVmax与FAPI表达呈中度相关(r=0.520,P=0.022);胶原、成纤维细胞活化蛋白和Ki-67在瘢痕疙瘩组织边缘的表达高于中心。
临床怎么用
- 原文结论认为68Ga-FAPI-04 PET/CT可反映瘢痕疙瘩组织中活化成纤维细胞的分布特征,并可能为瘢痕疙瘩评估及后续成纤维细胞相关治疗提供新方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Keloids are benign fibroproliferative disorders characterized by the massive proliferation of fibroblasts. Fibroblast activation plays a key role in the invasive growth of keloids. Therefore, a prospective pilot study was conducted to explore the value of 68 Ga-FAPI-04 PET/CT in the assessment of keloids activity. PATIENTS AND METHODS: Twenty-five patients with keloid were enrolled to conduct 68 Ga-FAPI-04 PET/CT. All patients accepted surgery to remove part of the lesions within 1 week. SUV mean and SUV max were measured for semiquantitative analysis and compared with the Vancouver Scar Scale, Laser Speckle Contrast Imaging, pathology, and immunohistochemical stains. RESULTS: A total of 123 lesions were detected in 25 patients, most of which were distributed in the anterior chest wall. The 68 Ga-FAPI-04 uptake was significantly different at different sites ( P < 0.0001). There was uptake heterogeneity within the keloid lesions, and a significant difference was found between the edge and center of some large lesions. The SUV max of 68 Ga-FAPI-04 showed significantly correlation with the Vancouver Scar Scale ( r = 0.565, P < 0.0001) moderately and the Laser Speckle Contrast Imaging parameters mildly. The SUV max of 68 Ga-FAPI-04 had a moderate correlation with FAPI expression ( r = 0.520, P = 0.022). Moreover, collagen, fibroblast activator protein, and Ki-67 expression were found higher at the edges of keloid tissue than in the center. CONCLUSIONS: 68 Ga-FAPI-04 PET/CT can reflect the distribution characteristics of activated fibroblasts in keloid tissue and may provide a novel method for keloid evaluation for further fibroblast-related therapies.
引用
- Wang J, Yu N, Wang G, et al. 68 Ga-FAPI-04 PET/CT in Assessment of Fibroblast Activation in Keloids : A Prospective Pilot Study. Clin Nucl Med. 2023. PMID: 38015039. doi:10.1097/RLU.0000000000004913
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。