文献速递肿瘤 PET/CT放射性药物与辐射防护

工作负荷过重与18F-FDG-PET/CT诊断错误相关吗

Is work overload associated with diagnostic errors on 18F-FDG-PET/CT?
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-11-30

本研究纳入2018年3月至2023年7月在一家三级医疗中心出现的103例经补充更正诊断错误的18F-FDG-PET/CT扫描,计算授权报告的核医学医师或放射科医师在出错当日的工作负荷(以其日均工作量归一化)。出错当日归一化工作负荷中位数为121%(四分位距71%至146%),显著高于100%(P=0.014);诊断错误频率在全天工作中未呈显著上升趋势(Mann-Kendall tau=0.05,P=0.7294)。结论认为工作负荷过重似乎与18F-FDG-PET/CT诊断错误相关。

要点

  • 出错当日归一化工作负荷中位数为121%(四分位距71%至146%),显著高于100%(P=0.014)。
  • 诊断错误频率在全天工作中无显著上升趋势(Mann-Kendall tau=0.05,P=0.7294)。
  • 诊断错误在整个工作日均有出现,未在临近下班时增多。

核心结论

  • 工作负荷过重似乎与18F-FDG-PET/CT诊断错误相关。
  • 诊断错误在整个工作日均有出现,未呈临近下班时增多的趋势。

研究设计与样本

  • 研究纳入2018年3月至2023年7月在一家三级医疗中心出现的103例经补充更正诊断错误的18F-FDG-PET/CT扫描。
  • 计算授权该报告的核医学医师或放射科医师在出错当日的工作负荷,并以其本人日均工作量归一化(归一化工作负荷)。

主要发现

  • 出错当日归一化工作负荷中位数为121%(四分位距71%至146%),显著高于100%(P=0.014)。
  • 诊断错误频率在全天工作中无显著上升趋势(Mann-Kendall tau=0.05,P=0.7294)。

关键数值与推荐

  • 归一化工作负荷超过100%表示出错当日该核医学医师或放射科医师存在相对工作负荷过重,低于100%表示相对工作负荷不足。
  • 以符号秩和检验将归一化工作负荷与100%比较,假设其显著超过100%(P=0.014)。
  • 以Mann-Kendall检验诊断错误是否随一天进程而增多(tau=0.05,P=0.7294)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine the association between workload and diagnostic errors on 18F-FDG-PET/CT. MATERIALS AND METHODS: This study included 103 18F-FDG-PET/CT scans with a diagnostic error that was corrected with an addendum between March 2018 and July 2023. All scans were performed at a tertiary care center. The workload of each nuclear medicine physician or radiologist who authorized the 18F-FDG-PET/CT report was determined on the day the diagnostic error was made and normalized for his or her own average daily production (workloadnormalized). A workloadnormalized of more than 100% indicates that the nuclear medicine physician or radiologist had a relative work overload, while a value of less than 100% indicates a relative work underload on the day the diagnostic error was made. The time of the day the diagnostic error was made was also recorded. Workloadnormalized was compared to 100% using a signed rank sum test, with the hypothesis that it would significantly exceed 100%. A Mann-Kendall test was performed to test the hypothesis that diagnostic errors would increase over the course of the day. RESULTS: Workloadnormalized (median of 121%, interquartile range: 71 to 146%) on the days the diagnostic errors were made was significantly higher than 100% (P = 0.014). There was no significant upward trend in the frequency of diagnostic errors over the course of the day (Mann-Kendall tau = 0.05, P = 0.7294). CONCLUSION: Work overload seems to be associated with diagnostic errors on 18F-FDG-PET/CT. Diagnostic errors were encountered throughout the entire working day, without any upward trend towards the end of the day.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Toxopeus R, Kasalak Ö, Yakar D, et al. Is work overload associated with diagnostic errors on 18F-FDG-PET/CT? Eur J Nucl Med Mol Imaging. 2023. PMID: 38030745. doi:10.1007/s00259-023-06543-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。