整合心肌血流储备(iMFR)评估:优化PET血流定量以诊断冠状动脉疾病

Integrated myocardial flow reserve (iMFR) assessment: optimized PET blood flow quantification for diagnosis of coronary artery disease.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-10-09

研究将心肌血流储备(MFR)与相对灌注定量结合构建整合MFR(iMFR),在1044例临床患者和231例Flurpiridaz 301试验患者中,以侵入性冠状动脉造影(ICA)验证。iMFR的局灶性灌注受损参数诊断阻塞性CAD的AUC为0.824,优于标准定量灌注的0.809,并与高危CAD解剖相关。

要点

  • iMFR局灶性灌注受损诊断阻塞性CAD的AUC为0.824,略优于标准定量灌注的0.809。
  • 局灶性灌注受损与高危CAD解剖相关:范围OR 1.40,平均MFR降低OR 2.40。
  • 弥漫性灌注受损在无短暂性缺血性扩张(TID)时有助于排除阻塞性和高危CAD。

核心结论

  • iMFR评估得出的局灶性灌注受损范围是阻塞性CAD的有力增量预测因子。
  • 弥漫性灌注受损范围在无TID时有助于排除阻塞性和高危CAD。

研究设计与样本

  • 研究纳入1044例接受82Rb静息/负荷PET心肌灌注显像和ICA的临床患者,以及231例Flurpiridaz 301试验(clinicaltrials.gov NCT01347710)患者。
  • 将MFR与相对灌注定量结合创建iMFR图,以ICA为参考标准评估iMFR对阻塞性狭窄的诊断增量价值,并校正患者人口学和CAD验前概率。
  • 还构建了高危解剖(左主干或三支血管病变)的模型。

主要发现

  • iMFR的局灶性灌注受损参数产生最佳拟合诊断模型。
  • ROC分析显示iMFR较标准定量灌注方法略有改善,AUC 0.824 vs 0.809。
  • 局灶性灌注受损与高危CAD解剖相关:范围OR 1.40,平均MFR降低OR 2.40。
  • 弥漫性灌注受损与阻塞性CAD可能性较低相关,且在无TID时与高危CAD解剖可能性较低相关。

关键数值与推荐

  • iMFR诊断阻塞性CAD的AUC为0.824,标准定量灌注方法为0.809。
  • 局灶性灌注受损范围与高危CAD解剖的OR为1.40,平均MFR降低的OR为2.40。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Distinguishing obstructive epicardial coronary artery disease (CAD) from microvascular dysfunction and diffuse atherosclerosis would be of immense benefit clinically. However, quantitative measures of absolute myocardial blood flow (MBF) integrate the effects of focal epicardial stenosis, diffuse atherosclerosis, and microvascular dysfunction. In this study, MFR and relative perfusion quantification were combined to create integrated MFR (iMFR) which was evaluated using data from a large clinical registry and an international multi-center trial and validated against invasive coronary angiography (ICA). METHODS: This study included 1,044 clinical patients referred for 82Rb rest/stress positron emission tomography myocardial perfusion imaging and ICA, along with 231 patients from the Flurpiridaz 301 trial (clinicaltrials.gov NCT01347710). MFR and relative perfusion quantification were combined to create an iMFR map. The incremental value of iMFR was evaluated for diagnosis of obstructive stenosis, adjusted for patient demographics and pre-test probability of CAD. Models for high-risk anatomy (left main or three-vessel disease) were also constructed. RESULTS: iMFR parameters of focally impaired perfusion resulted in best fitting diagnostic models. Receiver-operating characteristic analysis showed a slight improvement compared to standard quantitative perfusion approaches (AUC 0.824 vs. 0.809). Focally impaired perfusion was also associated with high-risk CAD anatomy (OR 1.40 for extent, and OR 2.40 for decreasing mean MFR). Diffusely impaired perfusion was associated with lower likelihood of obstructive CAD, and, in the absence of transient ischemic dilation (TID), with lower likelihood of high-risk CAD anatomy. CONCLUSIONS: Focally impaired perfusion extent derived from iMFR assessment is a powerful incremental predictor of obstructive CAD while diffusely impaired perfusion extent can help rule out obstructive and high-risk CAD in the absence of TID.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Poitrasson-Rivière A, Moody JB, Renaud JM, et al. Integrated myocardial flow reserve (iMFR) assessment: optimized PET blood flow quantification for diagnosis of coronary artery disease. Eur J Nucl Med Mol Imaging. 2023. PMID: 37807004. doi:10.1007/s00259-023-06455-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。