82Rb与[15O]H2O心肌灌注PET显像:一项前瞻性头对头比较

82Rb and [15O]H2O myocardial perfusion PET imaging: a prospective head to head comparison.
PubMed 文献 · J Nucl Cardiol · 2023-10-03

本研究在疑似缺血性心脏病患者中前瞻性头对头比较82Rb与[15O]H2O PET心肌灌注显像。[15O]H2O PET检出更多区域缺血患者(46% vs 24%),采用总灌注缺损≥10%标准后一致性提高至86%;作者结论认为从82Rb向[15O]H2O PET临床转换时需考虑[15O]H2O PET检出区域缺血频率更高。

要点

  • [15O]H2O PET检出区域缺血17例(46%),82Rb PET检出9例(24%)。
  • 采用总灌注缺损≥10%标准后两种显像一致性为86%,kappa为.62。
  • 无已知心脏病亚组(n=18)两种显像一致性为94%。

核心结论

  • 在从82Rb向[15O]H2O PET的临床转换中,需考虑[15O]H2O PET检出区域缺血患者的频率更高。

研究设计与样本

  • 前瞻性头对头比较研究,共纳入37例因疑似冠状动脉狭窄而转诊行灌注显像的患者,同日分别行82Rb与[15O]H2O PET静息及腺苷负荷显像。
  • 由两名设盲读片者将检查结果评为正常、区域缺血、全局心肌灌注减低或心肌瘢痕。

主要发现

  • [15O]H2O PET检出区域缺血17例(46%),82Rb PET检出9例(24%),一致性59%,Cohen kappa为.31(95%CI .08-.53,P < .001)。
  • 采用总灌注缺损≥10%作为更保守的缺血标志时,一致性提高至86%,kappa为.62(95%CI .33-.92,P = .001)。
  • 无已知心脏病亚组(n = 18)中,两种显像一致性为94%。
  • 读片者间一致性为95%,kappa为.89(95%CI .74-1.00,P < .001)。

关键数值与推荐

  • [15O]H2O PET区域缺血定义为两个相邻节段平均负荷灌注≤ 2.3 mL/(min·g)。
  • 总灌注缺损(TPD)≥ 10%作为更保守的缺血标志。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: 82Rb PET and [15O]H2O PET are both validated tracers for myocardical perfusion imaging but have not previously been compared clinically. During our site's transition from 82Rb to [15O]H2O PET, we performed a head-to-head comparison in a mixed population with suspected ischemic heart disease. METHODS: A total of 37 patients referred for perfusion imaging due to suspicion of coronary stenosis were examined with both 82Rb and [15O]H2O PET on the same day in rest and during adenosine-induced stress. The exams were rated by two blinded readers as normal, regional ischemia, globally reduced myocardial perfusion, or myocardial scarring. For [15O]H2O PET, regional ischemia was defined as two neighboring segments with average stress perfusion ≤ 2.3 mL/(min·g). Further, we evaluated a total perfusion deficit (TPD) of ≥ 10% as a more conservative marker of ischemia. RESULTS: [15O]H2O PET identified more patients with regional ischemia: 17(46%) vs 9(24%), agreement: 59% corresponding to a Cohen's kappa of .31 [95%CI .08-.53], (P < .001). Using the more conservative TPD ≥ 10%, the agreement increased to 86% corresponding to a kappa of .62 [95%CI .33-.92], (P = .001). For the subgroup of patients with no known heart disease (n = 18), the agreement was 94%. Interrater agreement was 95% corresponding to a kappa of .89 [95%CI .74-1.00] (P < .001). CONCLUSIONS: In clinical transition from 82Rb to [15O]H2O PET, it is important to take into account the higher frequency of patients with regional ischemia detected by [15O]H2O PET.