文献速递肿瘤 PET/CT核素与放射性配体治疗

前列腺癌中[68Ga]Ga-PSMA-11动态全身PET/CT参数成像与SUV成像的比较

Comparison of parametric imaging and SUV imaging with [68 Ga]Ga-PSMA-11 using dynamic total-body PET/CT in prostate cancer.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-10-04

纳入20例前列腺癌患者行动态全身[68Ga]Ga-PSMA-11 PET/CT,采用不可逆双组织室模型(2T3k)拟合获得净流入率(Ki),比较参数图像与SUV图像的图像质量和病灶-本底比等半定量指标。结果表明Ki图像较SUV图像噪声更少、病灶 conspicuous 更高,LBR、SNR、CNR显著更高(1.4-3.6倍),所有SUV图像可检测的病灶在Ki图像上均可检测。

要点

  • 20例前列腺癌患者动态全身[68Ga]Ga-PSMA-11 PET/CT,2T3k模型拟合良好。
  • Ki图像视觉评估噪声更少、病灶 conspicuous 更高,LBR、SNR、CNR较SUV图像高1.4-3.6倍。
  • SUV图像(55-60 min)检测的所有病灶在Ki图像上均可检测。

核心结论

  • 全身[68Ga]Ga-PSMA-11参数成像较SUV图像增强了病灶对比度并提高了病灶可检测性。
  • 参数成像可能作为前列腺癌精准诊断和治疗评估的影像生物标志物和诊疗一体化工具。

研究设计与样本

  • 纳入20例前列腺癌患者,行动态全身[68Ga]Ga-PSMA-11 PET/CT扫描。
  • 对每个组织时间-活性曲线拟合不可逆双组织室模型(2T3k),获得净流入率(Ki)。
  • 比较参数图像与SUV图像的图像质量及病灶-本底比(LBR)、信噪比(SNR)、对比噪声比(CNR)等半定量指标。

主要发现

  • 2T3k动力学模型在正常器官和病灶中均显示良好的模型拟合。
  • SUV图像(55-60 min)检测的所有病灶均可在Ki图像上检测到。
  • 正常器官和病理病灶中Ki与SUVmean、SUVmax均呈正相关且具有统计学显著性。
  • 正常器官和病理病灶中Ki与K1呈中度正相关(R=0.69,P<0.001;R=0.61,P<0.001),Ki与k3呈中度正相关(R=0.69,P<0.001;R=0.62,P<0.001)。
  • Ki图像视觉评估显示较SUV图像更少的图像噪声和更高的病灶 conspicuous。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Standardized uptake value (SUV) has been prevalently used to measure [68 Ga]Ga-PSMA-11 activity in prostate cancer, but it is susceptible to multiple factors. Parametric imaging allows for absolute quantification of tracer uptake and provides a better diagnostic accuracy that is crucial for lesion detection. However, the clinical significance of total-body parametric imaging of [68 Ga]Ga-PSMA-11 remains to be fully assessed. Therefore, the aim of our study is to delve into the diagnostic implications of total-body parametric imaging of [68 Ga]Ga-PSMA-11 PET/CT for patients with prostate cancer. METHODS: Twenty prostate cancer patients were included and underwent a dynamic total-body [68 Ga]Ga-PSMA-11 PET/CT scan. An irreversible two-tissue compartment model (2T3k) was fitted for each tissue time-to-activity curve, and the net influx rate (Ki) was obtained. The image quality and semi-quantitative analysis of lesion-to-background ratio (LBR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between parametric images and SUV images. RESULTS: Kinetic modeling using 2T3k demonstrated favorable model fitting in both normal organs and lesions. All of the lesions detected on SUV images (55-60 min) could be detected on Ki images. The correlation between Ki, SUVmean, and SUVmax in both normal organs and pathological lesions was found to be positive and statistically significant. Conversely, a moderate positive correlations were found between Ki and K1 (R = 0.69, P < 0.001; R = 0.61, P < 0.001) and Ki and k3 (R = 0.69, P < 0.001; R = 0.62, P < 0.001), in normal organs and pathological lesions, respectively. Visual assessment in Ki images showed less image noise and higher lesions conspicuity compared to SUV images. Ki image-derived LBR, SNR, and CBR of pathological lesions including primary tumors (PTs), lymph node metastases (LNMs) and bone metastases (BMs), exhibited remarkably higher folds (1.4-3.6 folds) compared to those derived from SUV of corresponding lesions. CONCLUSIONS: Total-body parametric imaging of [68 Ga]Ga-PSMA-11 enhanced lesion contrast and improved lesion detectability compared to SUV images. This may potentially serve as an imaging biomarker and theranostic tool for precise diagnosis and treatment evaluation in prostate cancer patients.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Chen R, Ng YL, Yang X, et al. Comparison of parametric imaging and SUV imaging with [68 Ga]Ga-PSMA-11 using dynamic total-body PET/CT in prostate cancer. Eur J Nucl Med Mol Imaging. 2023. PMID: 37792025. doi:10.1007/s00259-023-06456-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。