文献速递肿瘤 PET/CT放射性药物与辐射防护

长轴视野扫描仪上[18F]FDG PET/CT评估大血管炎需要新的半定量阈值

New thresholds in semi-quantitative [18F]FDG PET/CT are needed to assess large vessel vasculitis with long-axial field-of-view scanners.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-09-07

该研究回顾性纳入100例(50例大血管炎、50例对照)接受长轴视野[18F]FDG PET/CT的患者,计算三个区域大血管的SUVmax和SUVmean及肝脏归一化值。肝脏归一化值的诊断准确性高于未归一化值,作者认为长轴视野扫描仪需考虑不同于标准扫描仪的半定量阈值。

要点

  • 肝脏归一化值的AUC始终≥0.90,高于未归一化值的0.74-0.89。
  • 大血管炎患者中,主动脉上血管受累38例(76%),胸主动脉42例(84%),主动脉下血管26例(52%)。
  • 作者结论认为长轴视野PET/CT诊断大血管炎准确,但需考虑不同于文献报道的标准扫描仪阈值。

核心结论

  • 长轴视野[18F]FDG PET/CT在大血管炎诊断检查中准确,但半定量参数应考虑不同于文献报道的标准扫描仪阈值。

研究设计与样本

  • 回顾性评估100例患者(50例大血管炎、50例对照),均接受[18F]FDG长轴视野PET/CT。
  • 对3个区域(主动脉上、胸主动脉、主动脉下)大血管计算SUVmax和SUVmean,并归一化至肝脏活性(SUVmax/L-SUVmax和SUVmax/L-SUVmean)。

主要发现

  • 50例大血管炎患者中,主动脉上血管受累38例(76%),胸主动脉受累42例(84%),主动脉下血管受累26例(52%)。
  • 肝脏归一化值的诊断准确性高于未归一化值,AUC始终≥0.90 vs. 0.74-0.89。
  • 主动脉上血管最佳阈值:SUVmax/L-SUVmax为0.66,SUVmax/L-SUVmean为0.88。
  • 胸主动脉最佳阈值:SUVmax/L-SUVmax为1.0,SUVmax/L-SUVmean为1.30。
  • 主动脉下血管最佳阈值:SUVmax/L-SUVmax为0.83,SUVmax/L-SUVmean为1.11。

关键数值与推荐

  • 主动脉上血管:SUVmax/L-SUVmax阈值0.66,SUVmax/L-SUVmean阈值0.88。
  • 胸主动脉:SUVmax/L-SUVmax阈值1.0,SUVmax/L-SUVmean阈值1.30。
  • 主动脉下血管:SUVmax/L-SUVmax阈值0.83,SUVmax/L-SUVmean阈值1.11。

临床怎么用

  • 作者结论认为长轴视野[18F]FDG PET/CT诊断大血管炎准确,但半定量参数需考虑不同于标准扫描仪文献报道的阈值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: [18F]FDG PET/CT proved accurate in the diagnostic work-up of large vessel vasculitis (LVV). While a visual interpretation is currently considered adequate, several attempts have been made to integrate it with a semiquantitative evaluation. In this regard, there is the need to validate current or new thresholds for the semiquantitative parameters on long-axial field of view (LAFOV) scanners. METHODS: We retrospectively evaluated 100 patients (50 with LVV and 50 controls) who underwent [18F]FDG LAFOV PET/CT. Semiquantitative parameters (SUVmax and SUVmean) were calculated for large vessels in 3 districts (supra-aortic [SA], thoracic aorta [TA], and infra-aortic [IA]). Values were also normalized to liver activity (SUVmax/L-SUVmax, and SUVmax/L-SUVmean). RESULTS: Of the 50 patients diagnosed with LVV, SA vessels were affected in 38 (76%), TA in 42 (84%) and IA vessels in 26 (52%). To-liver normalized values had higher diagnostic accuracy than non-normalized values (AUC always ≥ 0.90 vs. 0.74-0.89). For the SA vessels, best thresholds were 0.66 for SUVmax/L-SUVmax and 0.88 for SUVmax/L-SUVmean; for the TA, 1.0 for SUVmax/L-SUVmax and 1.30 for SUVmax/L-SUVmean; finally, for IA vessels, the best threshold was 0.83 for SUVmax/L-SUVmax and 1.11 for SUVmax/L-SUVmean. CONCLUSION: LAFOV [18F]FDG-PET/CT is accurate in the diagnostic workup of LVV, but different threshold in semi-quantitative parameters than reported in literature for standard scanners should be considered.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Knappe L, Bregenzer C, Gözlügöl N, et al. New thresholds in semi-quantitative [18F]FDG PET/CT are needed to assess large vessel vasculitis with long-axial field-of-view scanners. Eur J Nucl Med Mol Imaging. 2023. PMID: 37676501. doi:10.1007/s00259-023-06423-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。