文献速递肿瘤 PET/CT心脏核医学

使用[11C]-丁醇进行全身灌注成像

Total-Body Perfusion Imaging with [11C]-Butanol.
PubMed 文献 · J Nucl Med · 2023-08-31

本研究在uEXPLORER全身PET/CT扫描仪上使用[11C]-丁醇开展试点研究,纳入8名参与者(6名健康志愿者和2名外周血管疾病患者),进行30分钟动态采集。结果显示重复基线灌注测量高度相关(斜率0.99;Pearson r=0.96,P<0.001),冷加压试验受试者骨骼肌和心肌灌注增加最大,方法能敏感反映生理应激和疾病引起的局部血流变化。

要点

  • 使用[11C]-丁醇可在全身PET/CT上获得可重复的全身灌注测量。
  • 冷加压试验中骨骼肌(腰大肌)灌注增加142%,心肌增加64%。
  • 方法能敏感检测生理应激和疾病导致的局部灌注变化。

核心结论

  • 本试点研究证明使用[11C]-丁醇可获得可重复的全身灌注测量,且方法对生理应激和疾病引起的局部血流变化敏感。

研究设计与样本

  • 试点研究,纳入8名参与者(6名健康志愿者和2名外周血管疾病患者),在uEXPLORER全身PET/CT扫描仪上注射[11C]-丁醇推注并进行30分钟动态采集。
  • 3名健康志愿者在静息状态(基线)重复研究以评估重测重复性;1名志愿者接受配对的静息和冷加压试验研究。
  • 使用单组织室模型和前缘延迟校正开发了区域和参数动力学分析方法。

主要发现

  • 估计的基线灌注值在各器官范围为0.02至1.95 mL·min-1·cm-3。
  • 重测分析显示重复基线灌注测量高度相关(斜率0.99;Pearson r=0.96,P<0.001)。
  • 冷加压试验受试者中,区域增加最大的是骨骼肌(腰大肌,142%)和心肌(64%)。
  • 1例外周血管疾病患者因外周狭窄显示小腿侧支血管生长增加。
  • 包括心肌梗死、甲状腺功能减退和肾衰竭在内的合并症与器官特异性灌注变化相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Tissue perfusion can be affected by physiology or disease. With the advent of total-body PET, quantitative measurement of perfusion across the entire body is possible. [11C]-butanol is a perfusion tracer with a superior extraction fraction compared with [15O]-water and [13N]-ammonia. To develop the methodology for total-body perfusion imaging, a pilot study using [11C]-butanol on the uEXPLORER total-body PET/CT scanner was conducted. Methods: Eight participants (6 healthy volunteers and 2 patients with peripheral vascular disease [PVD]) were injected with a bolus of [11C]-butanol and underwent 30-min dynamic acquisitions. Three healthy volunteers underwent repeat studies at rest (baseline) to assess test-retest reproducibility; 1 volunteer underwent paired rest and cold pressor test (CPT) studies. Changes in perfusion were measured in the paired rest-CPT study. For PVD patients, local changes in perfusion were investigated and correlated with patient medical history. Regional and parametric kinetic analysis methods were developed using a 1-tissue compartment model and leading-edge delay correction. Results: Estimated baseline perfusion values ranged from 0.02 to 1.95 mL·min-1·cm-3 across organs. Test-retest analysis showed that repeat baseline perfusion measurements were highly correlated (slope, 0.99; Pearson r = 0.96, P < 0.001). For the CPT subject, the largest regional increases were in skeletal muscle (psoas, 142%) and the myocardium (64%). One of the PVD patients showed increased collateral vessel growth in the calf because of a peripheral stenosis. Comorbidities including myocardial infarction, hypothyroidism, and renal failure were correlated with variations in organ-specific perfusion. Conclusion: This pilot study demonstrates the ability to obtain reproducible measurements of total-body perfusion using [11C]-butanol. The methods are sensitive to local perturbations in flow because of physiologic stressors and disease.

来源:J Nucl Med,查看原文。版权归原作者所有。