这项前瞻性横断面研究纳入24例慢性恰加斯心脏病门诊患者,比较合并复杂室性心律失常与无复杂室性心律失常两组,采用18F-FDG与68Ga-DOTATOC PET/CT检测心肌炎症,并定性评估寄生虫血症。两组示踪剂摄取比例相似,但复杂心律失常组68Ga-DOTATOC校正SUVmax更高(3.4 vs 1.7;P = .046)。

要点

  • 68Ga-DOTATOC校正SUVmax在复杂心律失常组为3.4,无复杂心律失常组为1.7,P = .046。
  • 复杂心律失常组恶性心律失常组寄生虫血症为66.7%,无恶性心律失常组为33.3%,差异无统计学显著趋势。
  • 18F-FDG和68Ga-DOTATOC PET/CT或可用于检测恰加斯心肌病心肌炎症。

核心结论

  • 18F-FDG和68Ga-DOTATOC PET/CT摄取可能有助于检测恰加斯心肌病患者的心肌炎症,68Ga-DOTATOC摄取可能与恶性心律失常的存在相关,并具有潜在治疗意义。

研究设计与样本

  • 前瞻性横断面研究纳入24例慢性恰加斯心脏病门诊患者,于2019年5月至2022年3月期间入组。
  • 患者分为两组:需要植入式心律转复除颤器的持续性室性心动过速和/或心脏骤停复苏者,以及处于相同恰加斯心脏病分期且无复杂室性心律失常者。
  • 患者接受18F-氟脱氧葡萄糖(18F-FDG)和68Ga-DOTATOC PET/CT检查,并采集血样通过聚合酶链反应进行寄生虫定性评估。

主要发现

  • 有和无复杂室性心律失常的患者显示18F-FDG和68Ga-DOTATOC摄取的比例相似。
  • 复杂心律失常组68Ga-DOTATOC校正SUVmax为3.4,无复杂心律失常组为1.7(P = .046)。
  • 两组均检出克氏锥虫,恶性心律失常组寄生虫血症为66.7%,无恶性心律失常组为33.3%,差异无统计学显著趋势。

关键数值与推荐

  • 复杂心律失常组68Ga-DOTATOC校正SUVmax为3.4,无复杂心律失常组为1.7(P = .046)。
  • 恶性心律失常组寄生虫血症为66.7%,无恶性心律失常组为33.3%,差异无统计学显著趋势。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Chagas heart disease (CHD) is characterized by progressive myocardial inflammation associated with myocardial fibrosis and segmental abnormalities that may lead to malignant ventricular arrhythmia and sudden cardiac death. This arrhythmia might be related to the persistence of parasitemia or inflammation in the myocardium in late-stage CHD. Positron emission tomography/computed tomography (PET/CT) has been used to detect myocardial inflammation in non-ischemic cardiomyopathies, such as sarcoidosis, and might be useful for risk prediction in patients with CHD. METHODS AND RESULTS: Twenty-four outpatients with chronic CHD were enrolled in this prospective cross-sectional study between May 2019 and March 2022. The patients were divided into two groups: those with sustained ventricular tachycardia and/or aborted sudden cardiac death who required implantable cardioverter-defibrillators, and those with the same stages of CHD and no complex ventricular arrhythmia. Patients underwent 18F-fluorodeoxyglucose (18F-FDG) and 68Ga-DOTATOC PET/CT, and blood samples were collected for qualitative parasite assessment by polymerase chain reaction. Although similar proportions of patients with and without complex ventricular arrhythmia showed 18F-FDG and 68Ga-DOTATOC uptake, 68Ga-DOTATOC corrected SUVmax was higher in patients with complex arrhythmia (3.4 vs 1.7; P = .046), suggesting that inflammation could be associated with the presence of malignant arrhythmia in the late stages of CHD. We also detected Trypanosoma cruzi in both groups, with a nonsignificant trend of increased parasitemia in the group with malignant arrhythmia (66.7% vs 33.3%). CONCLUSION: 18F-FDG and 68Ga-DOTATOC uptake on PET/CT may be useful for the detection of myocardial inflammation in patients with Chagas cardiomyopathy, and 68Ga-DOTATOC uptake may be associated with the presence of malignant arrhythmia, with potential therapeutic implications.