文献速递神经核医学甲状腺核医学

基于深度学习的眼眶SPECT/CT诊断Graves眼病患者疾病活动性

Deep learning-based diagnosis of disease activity in patients with Graves' orbitopathy using orbital SPECT/CT.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-07-03

本研究提出两阶段GO-Net模型,先以语义V-Net分割眼眶CT中的眼外肌,再用卷积神经网络结合SPECT/CT图像分类Graves眼病炎症活动性。共纳入湘雅医院478例患者956只眼(活动期475只、非活动期481只)。测试集灵敏度84.63%、特异度83.87%、AUC 0.89(p<0.01),眼外肌分割平均IOU为0.82,优于仅用CT的模型。

要点

  • GO-Net结合CT、SPECT与眼外肌掩膜,测试集诊断活动性GO的AUC为0.89(p<0.01)。
  • 测试集灵敏度84.63%、特异度83.87%,诊断性能优于仅用CT的模型。
  • 眼外肌分割模型平均IOU为0.82,Grad-CAM显示模型关注GO活动区域。

核心结论

  • 所提出的GO-Net模型能准确检测GO活动性,在GO诊断中具有较大潜力。

研究设计与样本

  • GO-Net分两阶段:语义V-Net分割网络(SV-Net)提取眼眶CT中的眼外肌,卷积神经网络(CNN)利用SPECT/CT图像及分割结果分类炎症活动性。
  • 纳入中南大学湘雅医院478例GO患者共956只眼,活动期475只、非活动期481只。
  • 分割任务采用194只眼的五折交叉验证进行训练与内部验证;分类任务用80%眼数据训练并进行内部五折交叉验证,其余20%眼数据用于测试。
  • 眼外肌感兴趣区由两名读片者手动勾画、一名经验丰富医师审核,作为分割任务的金标准;GO活动性依据临床活动评分(CAS)和SPECT/CT图像诊断。
  • 结果采用梯度加权类激活映射(Grad-CAM)进行解释与可视化。

主要发现

  • GO-Net模型结合CT、SPECT和眼外肌掩膜,在测试集区分活动性与非活动性GO的灵敏度为84.63%、特异度为83.87%、受试者工作特征曲线下面积(AUC)为0.89(p<0.01)。
  • 与仅用CT的模型相比,GO-Net模型表现出更优的诊断性能。
  • Grad-CAM显示GO-Net模型关注GO活动区域。
  • 眼外肌分割模型平均交并比(IOU)为0.82。

关键数值与推荐

  • GO活动性诊断依据临床活动评分(CAS)和SPECT/CT图像。
  • 测试集灵敏度84.63%、特异度83.87%、AUC 0.89(p<0.01)。
  • 眼外肌分割平均IOU为0.82。

临床怎么用

  • 原文结论认为GO-Net模型能准确检测GO活动性,在GO诊断中具有较大潜力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Orbital [99mTc]TcDTPA orbital single-photon emission computed tomography (SPECT)/CT is an important method for assessing inflammatory activity in patients with Graves' orbitopathy (GO). However, interpreting the results requires substantial physician workload. We aim to propose an automated method called GO-Net to detect inflammatory activity in patients with GO. MATERIALS AND METHODS: GO-Net had two stages: (1) a semantic V-Net segmentation network (SV-Net) that extracts extraocular muscles (EOMs) in orbital CT images and (2) a convolutional neural network (CNN) that uses SPECT/CT images and the segmentation results to classify inflammatory activity. A total of 956 eyes from 478 patients with GO (active: 475; inactive: 481) at Xiangya Hospital of Central South University were investigated. For the segmentation task, five-fold cross-validation with 194 eyes was used for training and internal validation. For the classification task, 80% of the eye data were used for training and internal fivefold cross-validation, and the remaining 20% of the eye data were used for testing. The EOM regions of interest (ROIs) were manually drawn by two readers and reviewed by an experienced physician as ground truth for segmentation GO activity was diagnosed according to clinical activity scores (CASs) and the SPECT/CT images. Furthermore, results are interpreted and visualized using gradient-weighted class activation mapping (Grad-CAM). RESULTS: The GO-Net model combining CT, SPECT, and EOM masks achieved a sensitivity of 84.63%, a specificity of 83.87%, and an area under the receiver operating curve (AUC) of 0.89 (p < 0.01) on the test set for distinguishing active and inactive GO. Compared with the CT-only model, the GO-Net model showed superior diagnostic performance. Moreover, Grad-CAM demonstrated that the GO-Net model placed focus on the GO-active regions. For EOM segmentation, our segmentation model achieved a mean intersection over union (IOU) of 0.82. CONCLUSION: The proposed Go-Net model accurately detected GO activity and has great potential in the diagnosis of GO.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Yao N, Li L, Gao Z, et al. Deep learning-based diagnosis of disease activity in patients with Graves' orbitopathy using orbital SPECT/CT. Eur J Nucl Med Mol Imaging. 2023. PMID: 37395800. doi:10.1007/s00259-023-06312-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。