文献速递心脏核医学

旧方法新视角:门控SPECT显像用于左心室收缩功能评估

A new perspective on an old method: gated SPECT imaging for left ventricular contractile function assessment.
PubMed 文献 · J Nucl Cardiol · 2023-07-25

研究利用门控SPECT测得的心室容积与动脉张力测量计算心室弹性(Ev)、动脉弹性(Ea)及舒张末期容积,分别作为收缩力、后负荷和前负荷的替代指标,对1462例连续患者评估左心室功能。心肌梗死患者收缩力降低(心室弹性3 mmHg/ml vs 6 mmHg/ml),通过前负荷增加(舒张末期容积100 ml vs 78 ml)和后负荷降低(动脉弹性1.8 mmHg/ml vs 2.2 ml/mmHg)代偿,两组射血分数均得以保持。

要点

  • 门控SPECT结合动脉张力测量可同时评估前负荷、后负荷和收缩力。
  • 心肌梗死患者心室弹性3 mmHg/ml低于无梗死患者6 mmHg/ml,提示收缩力降低。
  • 梗死组通过舒张末期容积100 ml高于78 ml及动脉弹性1.8低于2.2 mmHg/ml代偿,射血分数保持。

核心结论

  • 核医学显像与动脉张力测量相结合不仅反映射血分数,还纳入负荷背景,能更准确地反映心脏收缩力。

研究设计与样本

  • 应用门控SPECT测定的心室容积与动脉张力测量计算心室弹性、动脉弹性及舒张末期容积,对1462例连续患者进行评估,比较伴与不伴心肌梗死患者的心室功能。

主要发现

  • 中位左心室射血分数为68%(IQR 62-74%)。
  • 心肌梗死患者心室弹性为3 mmHg/ml,无梗死患者为6 mmHg/ml,提示收缩力降低。
  • 心肌梗死患者舒张末期容积为100 ml,无梗死患者为78 ml,提示前负荷增加。
  • 心肌梗死患者动脉弹性为1.8 mmHg/ml,无梗死患者为2.2 ml/mmHg,提示后负荷降低。
  • 两组射血分数均得以保持,门控SPECT测得的容积与文献报道值一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The ejection fraction (LVEF) is a commonly used marker of left ventricular function. However, because it is strongly influenced by loading conditions, it can be inaccurate in representing cardiac contractility. We therefore evaluated a gated SPECT based tool to simultaneously assess preload, afterload, and contractility. Using gated SPECT-determined ventricular volumes and arterial tension measurements, we calculated ventricular and arterial elastance (Ev and Ea), as well as end-diastolic volumes, which are surrogates for contractility, afterload, and preload, respectively. We applied this protocol to 1462 consecutive patients and assessed the ventricular function in patients with and without myocardial infarction. The median LVEF was 68% (IQR 62-74%). Patients with infarction exhibited decreased contractility (ventricular elastance of 3 mmHg/ml vs. 6 mmHg/ml), compensated by an increase of preload (end-diastolic volume of 100 ml vs. 78 ml) and a decrease in afterload (arterial elastance of 1.8 mmHg/ml vs. 2.2 ml/mmHg). These interactions yielded a preserved ejection fraction in both groups. Gated SPECT-measured volumes were consistent with values reported in the literature. In addition, the combination of nuclear imaging and arterial tension measurement accounted for not only the ejection fraction but also the loading context, providing a more accurate representation of cardiac contractility.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. San Miguel L, Goldschmidt E, Brisbin AK, et al. A new perspective on an old method: gated SPECT imaging for left ventricular contractile function assessment. J Nucl Cardiol. 2023. PMID: 37491510. doi:10.1007/s12350-023-03340-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。