心脏专用CZT SPECT的SPECT心肌血流量定量用于检测血管造影狭窄
本研究纳入180例患者行两日静息/腺苷负荷SPECT心肌血流量定量,采用CZT SPECT和一室两室动力学模型计算负荷MBF、MFR和MFC。以≥50%和≥70%狭窄为参照,MFC检测≥50%和≥70%病变的灵敏度(0.84-0.86、0.86-0.90)高于负荷MBF(0.78、0.78)和MFR(0.80、0.75),特异度相似。作者认为CZT SPECT无创MBF定量是检测血管造影阻塞性和血流受限性CAD的可靠方法。
要点
- 180例患者中,≥50%狭窄者149例(82.78%),≥70%狭窄者113例(62.78%)。
- 检测≥50%狭窄的负荷MBF和MFR最佳截断值分别为1.44 ml/min/g和1.96。
- MFC检测≥50%和≥70%病变的灵敏度高于负荷MBF和MFR,特异度相似。
核心结论
- 使用CZT SPECT的无创SPECT心肌血流量定量是检测血管造影阻塞性和血流受限性CAD的可靠方法。
- 心肌血流容量(MFC)的诊断灵敏度高于单独负荷MBF或MFR。
研究设计与样本
- 本研究纳入180例患者,行两日静息/腺苷负荷扫描用于SPECT心肌血流量定量。
- 所有动态SPECT图像经重建和必要校正,采用一室两室动力学模型通过数值优化拟合动力学参数(K1、k2和FBV),并由K1转换为MBF。
- 从血流极图计算左心室和冠状动脉供血区的静息MBF、负荷MBF和MFR;MFC通过整合血流图评估中度和重度异常血流状态的范围。
- 进行逐患者和逐血管分析,确定检测血管造影阻塞性和血流受限性CAD的截断值。
主要发现
- 以≥50%狭窄为阈值,149例患者(82.78%)被归类为阻塞性病变,涉及355支血管(65.74%)。
- 以≥70%狭窄为阈值,113例患者(62.78%)被归类为血流受限性病变,涉及282支血管(52.22%)。
- 逐患者分析中,检测≥50%狭窄的负荷MBF和MFR最佳截断值分别为1.44 ml/min/g和1.96,检测≥70%狭窄分别为1.34 ml/min/g和1.75。
- 重度异常和合并中度重度异常MFC范围的最佳截断值分别为2.3-2.5%和23.1%,以及7.5%和29.4%。
- MFC检测≥50%和≥70%病变的总体灵敏度(0.84-0.86、0.86-0.90)超过负荷MBF(0.78、0.78)和MFR(0.80、0.75)(均p < 0.05),特异度相似(MFC = 0.84-0.90、0.87-0.91;负荷MBF = 0.87、0.91;MFR = 0.84、0.89)(均p≥ 0.05)。
关键数值与推荐
- 检测≥50%狭窄的负荷MBF最佳截断值为1.44 ml/min/g,MFR最佳截断值为1.96(逐患者分析)。
- 检测≥70%狭窄的负荷MBF最佳截断值为1.34 ml/min/g,MFR最佳截断值为1.75(逐患者分析)。
- 重度异常MFC范围的最佳截断值为2.3-2.5%,合并中度重度异常MFC范围的最佳截断值为23.1%(检测≥50%狭窄)。
- 重度异常MFC范围的最佳截断值为7.5%,合并中度重度异常MFC范围的最佳截断值为29.4%(检测≥70%狭窄)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: CZT SPECT with the enhanced imaging characteristic facilitates SPECT myocardial blood flow (MBF) quantitation moving toward a clinical utility to uncover myocardial ischemia. The purpose of this study was to investigate the diagnostic performance of stress MBF, myocardial flow reserve (MFR) and myocardial flow capacity (MFC) derived from CZT SPECT in the detection of coronary artery disease (CAD). METHODS: One-hundred and eighty patients underwent two-day rest/adenosine-stress scans for SPECT MBF quantitation. All dynamic SPECT images were reconstructed and corrected with necessary corrections. The one-tissue two-compartment kinetic model was utilized to fit kinetic parameters (K1, k2 and FBV) by numeric optimization and converted to MBF from K1. Rest MBF, stress MBF and MFR in left ventricle and coronary territories were calculated from flow polar maps. MFC was assessed by extents of moderately and severely abnormal flow statuses using an integrated flow diagram. Per-patient and per-vessel analyses were performed to determine cutoff values for the detection of angiographically obstructive and flow-limited CAD. RESULTS: Using the threshold of ≥ 50% stenosis, 149 patients (82.78%) were classified to have obstructive lesions in 355 vessels (65.74%). Using the threshold of ≥ 70% stenosis, 113 patients (62.78%) were classified to have flow-limited lesions in 282 vessels (52.22%). On per-patient analysis, the optimal cutoff values of stress MBF and MFR to detect ≥ 50% stenosis were (1.44 ml/min/g, 1.96) and (1.34 ml/min/g and 1.75) to detect ≥ 70% stenosis. The optimal cutoff values for severely and combined moderately severely abnormal MFC extents were (2.3-2.5%, 23.1%) and (7.5%, 29.4%), respectively. The overall sensitivity of MFC (0.84-0.86, 0.86-0.90) to detect ≥ 50% and ≥ 70% lesions surpassed those of stress MBF (0.78. 0.78) and MFR (0.80, 0.75) (all p < 0.05) with similar specificity (MFC = 0.84-0.90, 0.87-0.91; stress MBF = 0.87, 0.91; MFR = 0.84, 0.89) (all p≥ 0.05). CONCLUSION: The non-invasive SPECT MBF quantitation using CZT SPECT is a reliable method to detect angiographically obstructive and flow-limited CAD. Myocardial flow capacity can outperform with higher diagnostic sensitivity than stress MBF or MFR alone.
引用
- Zhang J, Xie J, Li M, et al. SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT. J Nucl Cardiol. 2023. PMID: 37491508. doi:10.1007/s12350-023-03334-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。