注射后早期快速采集负荷优先的CZT SPECT心肌灌注显像联合替曲膦与衰减校正的准确性与效率
95例患者接受D-SPECT CZT系统负荷显像,比较注射后早期(平均17±2分钟)与标准延迟1小时(平均61±13分钟)图像。盲法判读显示需静息显像比例77.9%一致、整体诊断89.5%一致,图像质量与判读信心无显著差异,早期方案显著缩短检查时间(60±18分钟 vs 104±?分钟,p<0.001)。
要点
- 早期负荷显像与标准延迟显像在诊断和需静息显像判断上高度一致。
- 图像质量良好或优秀率早期87.4% vs 标准96.8%(p=0.09),无显著差异。
- 早期方案缩短从签到至负荷显像结束时间至60±18分钟(p<0.001)。
核心结论
- 使用99mTc替曲膦的CZT SPECT/CT注射后早期负荷-only显像在图像质量、判读信心、诊断和需静息扫描方面与标准延迟显像相似,结果看起来有前景。
研究设计与样本
- 95例转诊行SPECT MPI的患者,在Spectrum Dynamics D-SPECT CZT系统上行直立和仰卧位显像,采用CT衰减校正,于瑞加诺生负荷峰值注射99mTc替曲膦后采集。
主要发现
- 盲法判读对需静息显像的相同应答率为77.9%,整体诊断一致率为89.5%。
- 判读信心高:早期86.0% vs 标准90.3%(p=0.52)。
- 图像质量良好或优秀:早期87.4% vs 标准96.8%(p=0.09)。
- 从患者签到至负荷显像结束时间:标准组104±?分钟 vs 早期组60±18分钟(p<0.001)。
临床怎么用
- 原文未据此给出推荐。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Myocardial perfusion imaging (MPI) protocols have not changed significantly despite advances in instrumentation and software. We compared an early post-injection, stress-first SPECT protocol to standard delayed imaging. METHODS: 95 patients referred for SPECT MPI were imaged upright and supine on a Spectrum Dynamics D-SPECT CZT system with CT attenuation correction. Patients received injection of 99mTc tetrofosmin at peak of regadenoson stress and were imaged. Early post-stress (mean 17 ± 2 minutes) and Standard 1-h delay (mean 61 ± 13 min). Three blinded readers evaluated images for overall interpretation, perceived need for rest imaging, image quality, and reader confidence. Laboratory efficiency was also evaluated. RESULTS: Blinded readers had the same response for the need for rest in 77.9% of studies. Studies also had the same interpretation in 89.5% of studies. Reader confidence was high (86.0% (Early) and 90.3% (Standard p = 0.52. Image quality was good or excellent in 87.4% Early vs 96.8% Standard (p = 0.09). Time between patient check-in and end of stress imaging was 104 ± (Standard) to 60 ± 18 minutes (Early) (p < 0.001). CONCLUSION: Early post-injection stress-only imaging using CZT SPECT/CT appears promising with Tc-99m tetrofosmin with similar image quality, reader confidence, diagnosis, and need for a rest scan.
引用
- Case JA, Courter SA, McGhie A, et al. Accurate and efficient rapid acquisition early post-injection stress-first CZT SPECT myocardial perfusion imaging with tetrofosmin and attenuation correction. J Nucl Cardiol. 2023. PMID: 37464251. doi:10.1007/s12350-023-03336-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。