文献速递肿瘤 PET/CT

基于深度学习图像滤波器的亚分钟采集在全身18F-FDG PET/CT诊断结直肠癌中的应用

Sub-minute acquisition with deep learning-based image filter in the diagnosis of colorectal cancers using total-body 18F-FDG PET/CT.
PubMed 文献 · EJNMMI Res · 2023-07-10

本研究回顾性评估全身18F-FDG PET/CT超快采集联合深度学习图像滤波器诊断结直肠癌的可行性。34例结直肠癌患者行300秒列表模式扫描,数据集分为10、20、30、60、120秒采集组,分别用高斯滤波器和深度学习滤波器重建。深度学习滤波器显著改善图像质量和信噪比,20秒和30秒深度学习滤波图像在信噪比、SUVmax、靶本比和肝转移灶检出数目上与300秒高斯滤波图像无统计学差异。

要点

  • 10秒采集数据集因噪声过高无法评估,无论高斯还是深度学习滤波器。
  • 深度学习滤波器较高斯滤波器显著提高信噪比和视觉图像质量评分(P < 0.01)。
  • 20秒和30秒深度学习滤波图像与300秒高斯滤波图像在信噪比、SUVmax、靶本比及肝转移灶检出数目上无统计学差异(P > 0.05)。

核心结论

  • 深度学习滤波器可显著改善全身18F-FDG PET/CT超快采集的图像质量。
  • 基于深度学习的图像滤波方法可显著降低超快采集的噪声,使其有望适用于临床诊断。

研究设计与样本

  • 回顾性研究,收集结直肠癌患者的临床和术前影像数据。
  • 所有患者接受300秒列表模式全身18F-FDG PET/CT扫描,数据集分为10、20、30、60、120秒采集组。
  • PET图像采用有序子集期望最大化重建,后处理滤波器包括3 mm半高全宽高斯平滑滤波器和深度学习图像滤波器。
  • 以300秒高斯滤波图像为标准,用5点李克特量表和半定量分析比较不同采集时间下两种滤波器对图像质量、检出率和摄取值的影晌。
  • 共纳入34例结直肠癌患者,均为单发结直肠病灶且经病理验证,其中11例有肝转移,共检出113个肝转移灶。

主要发现

  • 10秒数据集因噪声过高无法评估,无论高斯还是深度学习滤波器。
  • 高斯滤波器下10、20、30、60秒采集图像的肝脏和纵隔血池信噪比低于300秒图像(P < 0.01)。
  • 深度学习滤波器较高斯滤波器显著改善信噪比和视觉图像质量评分(P < 0.01)。
  • 20秒和30秒深度学习滤波图像与300秒高斯滤波图像在肝脏和纵隔血池信噪比、结直肠癌和肝转移灶的SUVmax和靶本比、可检出肝转移灶数目上无统计学差异(P > 0.05)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to retrospectively evaluate the feasibility of total-body 18F-FDG PET/CT ultrafast acquisition combined with a deep learning (DL) image filter in the diagnosis of colorectal cancers (CRCs). METHODS: The clinical and preoperative imaging data of patients with CRCs were collected. All patients underwent a 300-s list-mode total-body 18F-FDG PET/CT scan. The dataset was divided into groups with acquisition durations of 10, 20, 30, 60, and 120 s. PET images were reconstructed using ordered subset expectation maximisation, and post-processing filters, including a Gaussian smoothing filter with 3 mm full width at half maximum (3 mm FWHM) and a DL image filter. The effects of the Gaussian and DL image filters on image quality, detection rate, and uptake value of primary and liver metastases of CRCs at different acquisition durations were compared using a 5-point Likert scale and semi-quantitative analysis, with the 300-s image with a Gaussian filter as the standard. RESULTS: All 34 recruited patients with CRCs had single colorectal lesions, and the diagnosis was verified pathologically. Of the total patients, 11 had liver metastases, and 113 liver metastases were detected. The 10-s dataset could not be evaluated due to high noise, regardless of whether it was filtered by Gaussian or DL image filters. The signal-to-noise ratio (SNR) of the liver and mediastinal blood pool in the images acquired for 10, 20, 30, and 60 s with a Gaussian filter was lower than that of the 300-s images (P < 0.01). The DL filter significantly improved the SNR and visual image quality score compared to the Gaussian filter (P < 0.01). There was no statistical difference in the SNR of the liver and mediastinal blood pool, SUVmax and TBR of CRCs and liver metastases, and the number of detectable liver metastases between the 20- and 30-s DL image filter and 300-s images with the Gaussian filter (P > 0.05). CONCLUSIONS: The DL filter can significantly improve the image quality of total-body 18F-FDG PET/CT ultrafast acquisition. Deep learning-based image filtering methods can significantly reduce the noise of ultrafast acquisition, making them suitable for clinical diagnosis possible.

来源:EJNMMI Res,查看原文。版权归原作者所有。