文献速递肿瘤 PET/CT放射性药物与辐射防护

血管移植物及腔内移植物感染中[18F]FDG-PET/LDCT报告变异性研究

Variability of [18F]FDG-PET/LDCT reporting in vascular graft and endograft infection.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-07-29

结果显示仅45.7%的报告包含全部预设条目,报告不完整与敏感度和特异度降低相关,作者建议在VGEI指南更新中纳入标准化报告标准。

要点

  • 仅45.7%的[18F]FDG-PET/LDCT报告纳入全部预设报告条目。
  • 评估最少的条目为FDG摄取模式,仅40.6%的报告涉及。
  • 纳入≤8条目的报告敏感度83%、特异度50%,低于完整评估报告的92%和77%。

核心结论

  • 不到一半的疑似VGEI的[18F]FDG-PET/LDCT报告满足全部预设标准,报告不完整导致敏感度和特异度降低。
  • 作者认为需要在VGEI指南更新中加入具体报告标准的推荐,本研究为疑似VGEI患者简明完整的[18F]FDG-PET/LDCT报告提供了首个推荐。

研究设计与样本

  • 回顾性队列研究,纳入2006至2022年间在三级转诊中心所有符合MAGIC标准、无需紧急手术治疗且额外接受[18F]FDG-PET/LDCT扫描的疑似VGEI患者。
  • 研究目的是评估[18F]FDG-PET/LDCT报告诊断VGEI(按MAGIC标准确诊)的完整性,并评价报告不完整是否影响诊断准确性。

主要发现

  • 从指标血管外科手术至[18F]FDG-PET/LDCT扫描的中位诊断间隔为35.5(7.3-73.3)个月。
  • 移植物位置65.1%位于中央、34.9%位于外周。
  • 基于预设报告标准,45.7%的报告包含全部条目;评估最少的条目为FDG摄取模式(40.6%)。
  • 与金标准(确诊VGEI)相比,[18F]FDG-PET/LDCT总体敏感度为91%、特异度为72%、准确率为88%。
  • 纳入≤8条目的报告敏感度和特异度分别为83%和50%,低于完整评估报告的92%和77%。

关键数值与推荐

  • 预设报告标准基于文献和领域专家制定,用于评分报告完整性。
  • VGEI确诊依据MAGIC标准。
  • 报告纳入≤8条目者敏感度83%、特异度50%;完整评估报告敏感度92%、特异度77%。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: 18F-fluoro-D-deoxyglucose positron emission tomography with low dose and/or contrast enhanced computed tomography ([18F]FDG-PET/CT) scan reveals high sensitivity for the diagnosis of vascular graft and endograft infection (VGEI), but lower specificity. Reporting [18F]FDG-PET/CT scans of suspected VGEI is challenging, reader dependent, and reporting standards are lacking. The aim of this study was to evaluate variability of [18F]FDG-PET/low dose CT (LDCT) reporting of suspected VGEI using a proposed standard reporting format. METHODS: A retrospective cohort study was conducted including all patients with a suspected VGEI (according to the MAGIC criteria) without need for urgent surgical treatment who underwent an additional [18F]FDG-PET/LDCT scan between 2006 and 2022 at a tertiary referral centre. All [18F]FDG-PET/LDCT reports were scored following pre-selected criteria that were formulated based on literature and experts in the field. The aim was to investigate the completeness of [18F]FDG-PET/LDCT reports for diagnosing VGEI (proven according to the MAGIC criteria) and to evaluate if incompleteness of reports influenced the diagnostic accuracy. RESULTS: Hundred-fifty-two patients were included. Median diagnostic interval from the index vascular surgical procedure until [18F]FDG-PET/LDCT scan was 35.5 (7.3-73.3) months. Grafts were in 65.1% located centrally and 34.9% peripherally. Based on the pre-selected reporting criteria, 45.7% of the reports included all items. The least frequently assessed criterion was FDG-uptake pattern (40.6%). Overall, [18F]FDG-PET/LDCT showed a sensitivity of 91%, a specificity of 72%, and an accuracy of 88% when compared to the gold standard (diagnosed VGEI). Lower sensitivity and specificity in reports including ≤ 8 criteria compared to completely evaluated reports were found (83% and 50% vs. 92% and 77%, respectively). CONCLUSION: Less than half of the [18F]FDG-PET/LDCT reports of suspected VGEI met all pre-selected criteria. Incompleteness of reports led to lower sensitivity and specificity. Implementing a recommendation with specific criteria for VGEI reporting is needed in the VGEI-guideline update. This study provides a first recommendation for a concise and complete [18F]FDG-PET/LDCT report in patients with suspected VGEI.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Liesker DJ, Legtenberg S, Erba PA, et al. Variability of [18F]FDG-PET/LDCT reporting in vascular graft and endograft infection. Eur J Nucl Med Mol Imaging. 2023. PMID: 37507493. doi:10.1007/s00259-023-06349-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。