文献速递心脏核医学

99mTc-Tektrotyd SPECT/CT在心肌梗死后炎症成像中的潜在价值

Potential utility of SPECT/CT with 99mTc-Tektrotyd for imaging of post-myocardial infarction inflammation.
PubMed 文献 · J Nucl Cardiol · 2023-06-14

研究纳入14例急性ST段抬高型前壁心肌梗死患者,于梗死后第7天行99mTc-Tektrotyd SPECT/CT、静息心肌灌注显像、心脏磁共振和经胸超声心动图,并与6个月超声心动图指标比较。7例患者心肌出现99mTc-Tektrotyd摄取,SUVmax与6个月心脏收缩功能指标、静息灌注总评分及磁共振梗死面积相关。

要点

  • 14例急性前壁STEMI患者中7例于梗死后第7天心肌出现99mTc-Tektrotyd摄取。
  • 99mTc-Tektrotyd SUVmax中位数1.59(1.38;2.83),静息灌注总评分中位数11(5;18)。
  • SUVmax与6个月舒张末期容积(r=0.81,P<0.05)及梗死面积(r=0.79,P<0.05)相关。

核心结论

  • 近期心肌梗死区域99mTc-Tektrotyd摄取强度(SUVmax)直接取决于缺血性心肌损伤范围,并与6个月随访期间心脏收缩功能指标的变化相关。

研究设计与样本

  • 研究纳入14例急性ST段抬高型前壁心肌梗死患者,行99mTc-Tektrotyd SPECT/CT、静息心肌灌注显像、心脏磁共振和经胸超声心动图检查,并与6个月经胸超声心动图指标比较。

主要发现

  • 心肌梗死后第7天,14例患者中7例心肌出现99mTc-Tektrotyd摄取。
  • 99mTc-Tektrotyd SUVmax中位数为1.59(1.38;2.83),静息灌注总评分中位数为11(5;18),磁共振梗死面积中位数为13.15(3.3;32.2)%。
  • 99mTc-Tektrotyd SUVmax与6个月舒张末期容积相关(r=0.81,P<0.05),与6个月舒张末期容积变化量相关(r=0.61,P<0.05)。
  • 99mTc-Tektrotyd SUVmax与静息灌注总评分相关(r=0.85,P<0.05),与磁共振梗死面积相关(r=0.79,P<0.05)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is a need to develop methods for post-myocardial infarction (MI) inflammation monitoring. Scintigraphy with somatostatin receptor targeted radiotracers has potential in this field. The purpose was to study the association of 99mTc-Tektrotyd uptake intensity in MI area with heart contractility indices over 6-month follow-up. METHODS: Fourteen patients with acute ST-segment elevation anterior MI (STEMI) were examined with 99mTc-Tektrotyd SPECT/CT, myocardial perfusion scintigraphy (MPS) at rest, cardiac magnetic resonance imaging (cMRI) and transthoracic echocardiography (TTE). Scintigraphic results were compared with 6-month TTE indices. RESULTS: On the 7th day after a MI onset, cardiac 99mTc-Tektrotyd uptake was found in 7 of 14 patients. Median of 99mTc-Tektrotyd SUVmax was 1.59 (1.38; 2.83), the summed rest score (SRS) was 11 (5; 18), infarct size (by cMRI)-13.15 (3.3; 32.2) %. 99mTc-Tektrotyd SUVmax strongly correlated with 6-month heart contractility indices (r = 0.81, P < 0.05 for the end diastolic volume; r = 0.61 P < 0.05 for Δ end diastolic volume), with SRS (r = 0.85, P < 0.05) and infarct size (by cMRI) (r = 0.79, P < 0.05). CONCLUSION: The intensity (SUVmax) of 99mTc-Tektrotyd uptake in the area of recent MI directly depends on the size of ischemic myocardial injury and correlates with changes of heart contractility indexes over the 6 month follow-up.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Sazonova SI, Ilyushenkova JN, Syrkina AG, et al. Potential utility of SPECT/CT with 99mTc-Tektrotyd for imaging of post-myocardial infarction inflammation. J Nucl Cardiol. 2023. PMID: 37316747. doi:10.1007/s12350-023-03312-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。